_version_ 1867172170722967552
author Elling, Felix J
Hemingway, Jordon D
Kharbush, Jenan
Becker, Kevin W
Polik, Catherine Ann
Pearson, Ann
author_facet Elling, Felix J
Hemingway, Jordon D
Kharbush, Jenan
Becker, Kevin W
Polik, Catherine Ann
Pearson, Ann
collection Datos científicos de ciencias marinas y ambientales
contents Heterocyst glycolipids (HGs) were analyzed using an Agilent 1290 ultra high-performance liquid chromatograph coupled to an Agilent 6410 triple quadrupole mass spectrometer equipped with an electrospray ionization interface operated in positive mode, following Wörmer et al. (2012). This work was supported by the Gordon and Betty Moore Foundation.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_936720
institution PANGAEA
language en
publishDate 2021
publisher PANGAEA
record_format pangaea
spellingShingle Table S3, Mass-to-charge ratios (m/z) of precursors and product ions as well as collision energies (CE) of diagnostic transitions during multiple reaction monitoring of heterocyst glycolipids at Quadrupole 1 (Q1) and 3 (Q3)
Elling, Felix J
Hemingway, Jordon D
Kharbush, Jenan
Becker, Kevin W
Polik, Catherine Ann
Pearson, Ann
Agilent 1290 ultrahigh performance liquid chromatograph coupled to an Agilent 6410 triple-quadrupole mass spectrometer; Anoxia; Bacteriohopanepolyols; Biomarkers; Collision energy; Compounds; d13C; d15N; GDGTs; heterocyst glycolipids; Mass-to-charge ratio; Mediterranean Sea; nitrogen cycle; Ocean Drilling Program; ODP; organic matter; sapropels; UPLC-QqQ-MS
Heterocyst glycolipids (HGs) were analyzed using an Agilent 1290 ultra high-performance liquid chromatograph coupled to an Agilent 6410 triple quadrupole mass spectrometer equipped with an electrospray ionization interface operated in positive mode, following Wörmer et al. (2012). This work was supported by the Gordon and Betty Moore Foundation.
title Table S3, Mass-to-charge ratios (m/z) of precursors and product ions as well as collision energies (CE) of diagnostic transitions during multiple reaction monitoring of heterocyst glycolipids at Quadrupole 1 (Q1) and 3 (Q3)
topic Agilent 1290 ultrahigh performance liquid chromatograph coupled to an Agilent 6410 triple-quadrupole mass spectrometer; Anoxia; Bacteriohopanepolyols; Biomarkers; Collision energy; Compounds; d13C; d15N; GDGTs; heterocyst glycolipids; Mass-to-charge ratio; Mediterranean Sea; nitrogen cycle; Ocean Drilling Program; ODP; organic matter; sapropels; UPLC-QqQ-MS
url https://doi.org/10.1594/PANGAEA.936720