Time series of water parameters, nutrient, and gas samples in the Coffs Creek estuary, March 2018

Fuente: PANGAEA
Salvato in:
Dettagli Bibliografici
Autore principale: Woodrow, Rebecca
Natura: Dataset Open Access
Lingua:en
Pubblicazione: PANGAEA 2021
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867170400945831936
author Woodrow, Rebecca
author_facet Woodrow, Rebecca
collection Datos científicos de ciencias marinas y ambientales
contents Measurements of water parameters of temperature, dissolved oxygen, and salinity as well as nutrient samples of dissolved organic carbon, filtered and unfiltered nitrogen, and nitrous oxide were collected through time series apparatus, hourly and 3 hourly, over 185 hours and exclusively at one site in the lower estuary (Site 1). A calibrated Hydrolab MS5 sonde measured and logged water temperature (±0.02°C), DO (±0.2 mg/L), and salinity (±0.02) at 30 m intervals and a depth logger (CTD diver) measured water depth in 15-minute intervals. Nutrient samples (including duplicates), filtered and unfiltered, were collected with a sample-rinsed 60 mL polyethylene syringe. Samples for dissolved organic carbon (DOC) analysis were filtered using pre-combusted 0.7 µm GF/F filters (Whatman), into 40 mL borosilicate vials (USP Type I). Samples for nitrogen were immediately filtered using Satourious ™ 0.45μm cellulose acetate syringe filters into 10 mL polyethylene sample tubes. All samples were kept in a cold icebox, away from light, for less than 5 hours and then frozen until laboratory analysis. Nutrient analysis of DOC was performed with the 40 mL borosilicate vials (USP Type I) first treated with 30 µL of H3PO4 before analysis using an Aurora 1030W TOC Analyser (Thermo Fisher Scientific, ConFLo IV). Nutrient analysis of ammonium (NH4+), NOx (nitrate plus nitrite), and total dissolved nitrogen (TDN) was performed on the 10 mL polyethylene sample tubes colourimetrically using a Lachat Flow Injection Analyser. Total dissolved nitrogen and dissolved inorganic nitrogen were calculated from the nitrogen samples. N2O samples were collected from a time series gas equilibration device via a one-way valve into 150 mL syringes then transferred from the syringes into a Supelco company 1 L gasbag. A total of 800 mL of gas was taken per sample. The gasbags were analysed for N2O using cavity ringdown spectroscopy on a calibrated Picarro G2308.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_937739
institution PANGAEA
language en
publishDate 2021
publisher PANGAEA
record_format pangaea
spellingShingle Time series of water parameters, nutrient, and gas samples in the Coffs Creek estuary, March 2018
Woodrow, Rebecca
Carbon, organic, dissolved; Coffs_Creek_estuary_time-series; DATE/TIME; DEPTH, water; Greenhouse gases; Hydrolab MS5; hydrology; Nitrogen, inorganic, dissolved; Nitrogen, total dissolved; Nitrous oxide, dissolved; Oxygen, dissolved; porewater exchange; Salinity, absolute; see abstract; Site; Tasman Sea; Temperature, water; Water sample; wetlands; WS
Measurements of water parameters of temperature, dissolved oxygen, and salinity as well as nutrient samples of dissolved organic carbon, filtered and unfiltered nitrogen, and nitrous oxide were collected through time series apparatus, hourly and 3 hourly, over 185 hours and exclusively at one site in the lower estuary (Site 1). A calibrated Hydrolab MS5 sonde measured and logged water temperature (±0.02°C), DO (±0.2 mg/L), and salinity (±0.02) at 30 m intervals and a depth logger (CTD diver) measured water depth in 15-minute intervals. Nutrient samples (including duplicates), filtered and unfiltered, were collected with a sample-rinsed 60 mL polyethylene syringe. Samples for dissolved organic carbon (DOC) analysis were filtered using pre-combusted 0.7 µm GF/F filters (Whatman), into 40 mL borosilicate vials (USP Type I). Samples for nitrogen were immediately filtered using Satourious ™ 0.45μm cellulose acetate syringe filters into 10 mL polyethylene sample tubes. All samples were kept in a cold icebox, away from light, for less than 5 hours and then frozen until laboratory analysis. Nutrient analysis of DOC was performed with the 40 mL borosilicate vials (USP Type I) first treated with 30 µL of H3PO4 before analysis using an Aurora 1030W TOC Analyser (Thermo Fisher Scientific, ConFLo IV). Nutrient analysis of ammonium (NH4+), NOx (nitrate plus nitrite), and total dissolved nitrogen (TDN) was performed on the 10 mL polyethylene sample tubes colourimetrically using a Lachat Flow Injection Analyser. Total dissolved nitrogen and dissolved inorganic nitrogen were calculated from the nitrogen samples. N2O samples were collected from a time series gas equilibration device via a one-way valve into 150 mL syringes then transferred from the syringes into a Supelco company 1 L gasbag. A total of 800 mL of gas was taken per sample. The gasbags were analysed for N2O using cavity ringdown spectroscopy on a calibrated Picarro G2308.
title Time series of water parameters, nutrient, and gas samples in the Coffs Creek estuary, March 2018
topic Carbon, organic, dissolved; Coffs_Creek_estuary_time-series; DATE/TIME; DEPTH, water; Greenhouse gases; Hydrolab MS5; hydrology; Nitrogen, inorganic, dissolved; Nitrogen, total dissolved; Nitrous oxide, dissolved; Oxygen, dissolved; porewater exchange; Salinity, absolute; see abstract; Site; Tasman Sea; Temperature, water; Water sample; wetlands; WS
url https://doi.org/10.1594/PANGAEA.937739