XRF data sheet: overbank silt-clay deposition sampling (4*4 km grid, Weiße Elster catchment, Salsitz-Trebnitz section)

Fuente: PANGAEA
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Ballasus, Helen, Zielhofer, Christoph, Schneider, Birgit, von Suchodoletz, Hans
Format: Dataset Open Access
Langue:en
Publié: PANGAEA 2021
Sujets:
Aluminium; Aluminium, error; Antimony; Antimony, error; Arsenic; Arsenic, error; Barium; Barium, error; Bismuth; Bismuth, error; Bromine; Bromine, error; Cadmium; Cadmium, error; Caesium; Caesium, error; Calcium; Calcium, error; catchment; Cerium; Cerium, error; Chloride; Chlorine, error; Chromium; Chromium, error; Cobalt; Cobalt, error; Copper; Copper, error; Elements, total; Event label; Fluvial sediments; Gallium; Gallium, error; Germanium; Germanium, error; Hafnium; Hafnium, error; Iodine; Iodine, error; Iron; Iron, error; Lanthanum; Lanthanum, error; LATITUDE; Lead; Lead, error; LONGITUDE; Magnesium; Magnesium, error; Manganese; Manganese, error; Mercury; Mercury, error; Molybdenum; Neodymium; Neodymium, error; Nickel; Nickel, error; Niobium; Niobium, error; Phosphorus; Phosphorus, error; Potassium; Potassium, error; Praseodymium; Praseodymium, error; Rubidium; Rubidium, error; Sample code/label; Selenium; Selenium, error; Silicon; Silicon, error; Silver; Silver, error; Sodium; Sodium, error; Strontium; Strontium, error; Sulfur; Sulfur, error; Tantalum; Tantalum, error; Tellurium; Tellurium, error; Thallium; Thallium, error; Thorium; Thorium, error; Tin; Tin, error; Titanium; Titanium, error; Tungsten; Tungsten, error; Uranium; Uranium, error; Vanadium; Vanadium, error; Weiße Elster; Weiße-Elster_WE41; Weiße-Elster_WE42; Weiße-Elster_WE50; Weiße-Elster_WE51; Weiße Elster, Germany; X-ray fluorescence spectrometry, Spectro XEPOS energy disersive; XRF data; Yttrium; Yttrium, error; Zinc; Zinc, error; Zirconium; Zirconium, error
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1867169147975106560
author Ballasus, Helen
Zielhofer, Christoph
Schneider, Birgit
von Suchodoletz, Hans
author_facet Ballasus, Helen
Zielhofer, Christoph
Schneider, Birgit
von Suchodoletz, Hans
collection Datos científicos de ciencias marinas y ambientales
contents We used stationary XRF spectrometry for analysing elemental composition of bank and streambed samples from Weiße Elster sub-basins (refined grids of 4*4 km). For XRF sample preparation freeze-dried catchment sediments (8 g) were seaved (2mm) to discard the gravel fraction and large organic matter. Further homogenization was undertaken by grinding the samples with a vibratory Retsch mill MM 200. We created uniform pellets by pressing the powdered samples with a carbon-based binding agent in a Vaneox press at 20 t for 2 min. We conducted elemental analyses in a He atmosphere using a Spectro Xepos energy dispersive XRF spectrometer. The XRF element data of the refined 4*4 km sampling grid of recent fluvial sediments in the direct proximity to the Salsitz transect are provided here. The data set has to be understood as a supplement or densification of the 8*8 km sampling grid of the Weiße Elster river catchment: doi:10.1594/PANGAEA.937926.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_937937
institution PANGAEA
language en
publishDate 2021
publisher PANGAEA
record_format pangaea
spellingShingle XRF data sheet: overbank silt-clay deposition sampling (4*4 km grid, Weiße Elster catchment, Salsitz-Trebnitz section)
Ballasus, Helen
Zielhofer, Christoph
Schneider, Birgit
von Suchodoletz, Hans
Aluminium; Aluminium, error; Antimony; Antimony, error; Arsenic; Arsenic, error; Barium; Barium, error; Bismuth; Bismuth, error; Bromine; Bromine, error; Cadmium; Cadmium, error; Caesium; Caesium, error; Calcium; Calcium, error; catchment; Cerium; Cerium, error; Chloride; Chlorine, error; Chromium; Chromium, error; Cobalt; Cobalt, error; Copper; Copper, error; Elements, total; Event label; Fluvial sediments; Gallium; Gallium, error; Germanium; Germanium, error; Hafnium; Hafnium, error; Iodine; Iodine, error; Iron; Iron, error; Lanthanum; Lanthanum, error; LATITUDE; Lead; Lead, error; LONGITUDE; Magnesium; Magnesium, error; Manganese; Manganese, error; Mercury; Mercury, error; Molybdenum; Neodymium; Neodymium, error; Nickel; Nickel, error; Niobium; Niobium, error; Phosphorus; Phosphorus, error; Potassium; Potassium, error; Praseodymium; Praseodymium, error; Rubidium; Rubidium, error; Sample code/label; Selenium; Selenium, error; Silicon; Silicon, error; Silver; Silver, error; Sodium; Sodium, error; Strontium; Strontium, error; Sulfur; Sulfur, error; Tantalum; Tantalum, error; Tellurium; Tellurium, error; Thallium; Thallium, error; Thorium; Thorium, error; Tin; Tin, error; Titanium; Titanium, error; Tungsten; Tungsten, error; Uranium; Uranium, error; Vanadium; Vanadium, error; Weiße Elster; Weiße-Elster_WE41; Weiße-Elster_WE42; Weiße-Elster_WE50; Weiße-Elster_WE51; Weiße Elster, Germany; X-ray fluorescence spectrometry, Spectro XEPOS energy disersive; XRF data; Yttrium; Yttrium, error; Zinc; Zinc, error; Zirconium; Zirconium, error
We used stationary XRF spectrometry for analysing elemental composition of bank and streambed samples from Weiße Elster sub-basins (refined grids of 4*4 km). For XRF sample preparation freeze-dried catchment sediments (8 g) were seaved (2mm) to discard the gravel fraction and large organic matter. Further homogenization was undertaken by grinding the samples with a vibratory Retsch mill MM 200. We created uniform pellets by pressing the powdered samples with a carbon-based binding agent in a Vaneox press at 20 t for 2 min. We conducted elemental analyses in a He atmosphere using a Spectro Xepos energy dispersive XRF spectrometer. The XRF element data of the refined 4*4 km sampling grid of recent fluvial sediments in the direct proximity to the Salsitz transect are provided here. The data set has to be understood as a supplement or densification of the 8*8 km sampling grid of the Weiße Elster river catchment: doi:10.1594/PANGAEA.937926.
title XRF data sheet: overbank silt-clay deposition sampling (4*4 km grid, Weiße Elster catchment, Salsitz-Trebnitz section)
topic Aluminium; Aluminium, error; Antimony; Antimony, error; Arsenic; Arsenic, error; Barium; Barium, error; Bismuth; Bismuth, error; Bromine; Bromine, error; Cadmium; Cadmium, error; Caesium; Caesium, error; Calcium; Calcium, error; catchment; Cerium; Cerium, error; Chloride; Chlorine, error; Chromium; Chromium, error; Cobalt; Cobalt, error; Copper; Copper, error; Elements, total; Event label; Fluvial sediments; Gallium; Gallium, error; Germanium; Germanium, error; Hafnium; Hafnium, error; Iodine; Iodine, error; Iron; Iron, error; Lanthanum; Lanthanum, error; LATITUDE; Lead; Lead, error; LONGITUDE; Magnesium; Magnesium, error; Manganese; Manganese, error; Mercury; Mercury, error; Molybdenum; Neodymium; Neodymium, error; Nickel; Nickel, error; Niobium; Niobium, error; Phosphorus; Phosphorus, error; Potassium; Potassium, error; Praseodymium; Praseodymium, error; Rubidium; Rubidium, error; Sample code/label; Selenium; Selenium, error; Silicon; Silicon, error; Silver; Silver, error; Sodium; Sodium, error; Strontium; Strontium, error; Sulfur; Sulfur, error; Tantalum; Tantalum, error; Tellurium; Tellurium, error; Thallium; Thallium, error; Thorium; Thorium, error; Tin; Tin, error; Titanium; Titanium, error; Tungsten; Tungsten, error; Uranium; Uranium, error; Vanadium; Vanadium, error; Weiße Elster; Weiße-Elster_WE41; Weiße-Elster_WE42; Weiße-Elster_WE50; Weiße-Elster_WE51; Weiße Elster, Germany; X-ray fluorescence spectrometry, Spectro XEPOS energy disersive; XRF data; Yttrium; Yttrium, error; Zinc; Zinc, error; Zirconium; Zirconium, error
url https://doi.org/10.1594/PANGAEA.937937