_version_ 1867171030310584320
author Hoover, Jeffery
Earle, Michael E
Joe, Paul
author_facet Hoover, Jeffery
Earle, Michael E
Joe, Paul
collection Datos científicos de ciencias marinas y ambientales
contents Collection efficiency transfer functions that compensate for wind-induced collection loss are presented and evaluated for unshielded precipitation gauges. Three novel transfer functions with wind speed and precipitation fall velocity dependence are developed, including a function from computational fluid dynamics modelling (CFD), an experimental fall velocity threshold function (HE1), and an experimental linear fall velocity dependence function (HE2). These functions are evaluated alongside universal (KUniversal) and climate-specific (KCARE) transfer functions with wind speed and temperature dependence. Transfer function performance is assessed using 30-minute precipitation event accumulations reported by unshielded and shielded Geonor T-200B3 precipitation gauges over two winter seasons. The latter gauge was installed in a Double Fence Automated Reference (DFAR) configuration. Estimates of fall velocity were provided by a Precipitation Occurrence Sensor System (POSS). The CFD function reduced the RMSE (0.08 mm) relative to KUniversal (0.20 mm), KCARE (0.13 mm), and the unadjusted measurements (0.24 mm), with a bias error of 0.011 mm. The HE1 function provided a RMSE of 0.09 mm and bias error of 0.006 mm, capturing well the collection efficiency trends for rain and snow. The HE2 function better captured the overall collection efficiency, including mixed precipitation, resulting in a RMSE of 0.07 mm and bias error of 0.006 mm. These functions are assessed across solid and liquid hydrometeor types and for temperatures between -22 °C and 19 °C. The results demonstrate that transfer functions incorporating hydrometeor fall velocity can dramatically reduce the uncertainty of adjusted precipitation measurements relative to functions based on temperature.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_938685
institution PANGAEA
language en
publishDate 2021
publisher PANGAEA
record_format pangaea
spellingShingle Unshielded precipitation gauge collection efficiency with wind speed and hydrometeor fall velocity
Hoover, Jeffery
Earle, Michael E
Joe, Paul
Canada; CAR, Centre for Atmospheric Research Experiments; CARE_SPICE; catch efficiency; CFD - Computational fluid dynamics modelling function; collection efficiency; DATE/TIME; DFAR - Double Fence Automated Reference; Fall velocity; HE1 - Experimental fall velocity threshold function; HE2 - Experimental linear fall velocity dependence function; HEIGHT above ground; KCARE - Climate-specific transfer function; KUniversal - Universal transfer function; Monitoring station; MONS; Precipitation; precipitation amount; Precipitation description; precipitation gauge; Precipitation Occurrence Sensor System; Solid Precipitation Intercomparison Experiment; SPICE; Temperature, air; unshielded; Unshielded; Wind speed
Collection efficiency transfer functions that compensate for wind-induced collection loss are presented and evaluated for unshielded precipitation gauges. Three novel transfer functions with wind speed and precipitation fall velocity dependence are developed, including a function from computational fluid dynamics modelling (CFD), an experimental fall velocity threshold function (HE1), and an experimental linear fall velocity dependence function (HE2). These functions are evaluated alongside universal (KUniversal) and climate-specific (KCARE) transfer functions with wind speed and temperature dependence. Transfer function performance is assessed using 30-minute precipitation event accumulations reported by unshielded and shielded Geonor T-200B3 precipitation gauges over two winter seasons. The latter gauge was installed in a Double Fence Automated Reference (DFAR) configuration. Estimates of fall velocity were provided by a Precipitation Occurrence Sensor System (POSS). The CFD function reduced the RMSE (0.08 mm) relative to KUniversal (0.20 mm), KCARE (0.13 mm), and the unadjusted measurements (0.24 mm), with a bias error of 0.011 mm. The HE1 function provided a RMSE of 0.09 mm and bias error of 0.006 mm, capturing well the collection efficiency trends for rain and snow. The HE2 function better captured the overall collection efficiency, including mixed precipitation, resulting in a RMSE of 0.07 mm and bias error of 0.006 mm. These functions are assessed across solid and liquid hydrometeor types and for temperatures between -22 °C and 19 °C. The results demonstrate that transfer functions incorporating hydrometeor fall velocity can dramatically reduce the uncertainty of adjusted precipitation measurements relative to functions based on temperature.
title Unshielded precipitation gauge collection efficiency with wind speed and hydrometeor fall velocity
topic Canada; CAR, Centre for Atmospheric Research Experiments; CARE_SPICE; catch efficiency; CFD - Computational fluid dynamics modelling function; collection efficiency; DATE/TIME; DFAR - Double Fence Automated Reference; Fall velocity; HE1 - Experimental fall velocity threshold function; HE2 - Experimental linear fall velocity dependence function; HEIGHT above ground; KCARE - Climate-specific transfer function; KUniversal - Universal transfer function; Monitoring station; MONS; Precipitation; precipitation amount; Precipitation description; precipitation gauge; Precipitation Occurrence Sensor System; Solid Precipitation Intercomparison Experiment; SPICE; Temperature, air; unshielded; Unshielded; Wind speed
url https://doi.org/10.1594/PANGAEA.938685