Concentrations of individual polychlorinated biphenyl congeners from Standard Reference Material (SRM) 1944

Fuente: PANGAEA
Guardado en:
Detalles Bibliográficos
Autores principales: Martinez, Andres, Hua, Jason, Haque, Ezazul, Thorne, Peter, Hornbuckle, Keri C
Formato: Dataset Open Access
Lenguaje:en
Publicado: PANGAEA 2022
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1867168504560484352
author Martinez, Andres
Hua, Jason
Haque, Ezazul
Thorne, Peter
Hornbuckle, Keri C
author_facet Martinez, Andres
Hua, Jason
Haque, Ezazul
Thorne, Peter
Hornbuckle, Keri C
collection Datos científicos de ciencias marinas y ambientales
contents Five Standard Reference Material 1944, New York, New Jersey Waterway sediment (SRM 1944, National Institutes of Standards and Testing) were extracted, cleaned and quantified using the same method for soils. Gas chromatography (GC) in tandem with Mass Spectrometry GC-MS/MS (Agilent 7000) in multiple reaction monitoring (MRM) mode was used to quantify all 28 individual or coeluting certified congeners. The GC was equipped with a Supelco SBP-Octyl capillary column (30 m × 0.25 mm ID, 0.25 mm film thicknesses) with helium as carrier gas.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_941883
institution PANGAEA
language en
publishDate 2022
publisher PANGAEA
record_format pangaea
spellingShingle Concentrations of individual polychlorinated biphenyl congeners from Standard Reference Material (SRM) 1944
Martinez, Andres
Hua, Jason
Haque, Ezazul
Thorne, Peter
Hornbuckle, Keri C
Method comment; PCB congeners; Polychlorinated biphenyl, per unit sediment dry mass; Sample code/label; Soil; tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM); TOC
Five Standard Reference Material 1944, New York, New Jersey Waterway sediment (SRM 1944, National Institutes of Standards and Testing) were extracted, cleaned and quantified using the same method for soils. Gas chromatography (GC) in tandem with Mass Spectrometry GC-MS/MS (Agilent 7000) in multiple reaction monitoring (MRM) mode was used to quantify all 28 individual or coeluting certified congeners. The GC was equipped with a Supelco SBP-Octyl capillary column (30 m × 0.25 mm ID, 0.25 mm film thicknesses) with helium as carrier gas.
title Concentrations of individual polychlorinated biphenyl congeners from Standard Reference Material (SRM) 1944
topic Method comment; PCB congeners; Polychlorinated biphenyl, per unit sediment dry mass; Sample code/label; Soil; tandem mass spectrometry (GC-MS/MS) in multiple reaction monitoring mode (MRM); TOC
url https://doi.org/10.1594/PANGAEA.941883