Wet chemical surface ozone measurements during POLARSTERN cruise ANT-I/1 (PS01) in 1982/83

Fuente: PANGAEA
Enregistré dans:
Détails bibliographiques
Auteur principal: Winkler, Peter
Format: Dataset Open Access
Langue:en
Publié: PANGAEA 2022
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1867168215884365824
author Winkler, Peter
author_facet Winkler, Peter
collection Datos científicos de ciencias marinas y ambientales
contents On the outward journey, European air masses, loaded by photochemically produced ozone, may have partly influenced the measurements in clean air. As simultaneously measured low concentrations of Krypton-85 (which only has anthropogenic sources) show, the high ozone mixing ratios at 0-5°N cannot be explained by photochemical formation, but must be of natural origin. On the return journey, the ITCZ was at 6°S and was weak. This explains the very low ozone values of only 4 ppb at times, caused by the photolysis of ozone. The ozone device was housed in the crow's nest, to avoid ship-polluted interference. At later cruises, the instrument was placed near the weather station, because the maintenance in the crow’s nest was impractical and the new air intake at the uppermost railing turned out to be suitable as well. As a precaution, the air pump was changed nine times during the trip. At the end of the last section, the pump wobbled a little, resulting in a five percent loss of production, which could be corrected
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_944260
institution PANGAEA
language en
publishDate 2022
publisher PANGAEA
record_format pangaea
spellingShingle Wet chemical surface ozone measurements during POLARSTERN cruise ANT-I/1 (PS01) in 1982/83
Winkler, Peter
ANT-I/1; CT; DATE/TIME; Electrochemical concentration cell (ECC) (Atmannspacher 1971); LATITUDE; LONGITUDE; Ozone; Polarstern; PS01; PS01/1-track; Underway cruise track measurements
On the outward journey, European air masses, loaded by photochemically produced ozone, may have partly influenced the measurements in clean air. As simultaneously measured low concentrations of Krypton-85 (which only has anthropogenic sources) show, the high ozone mixing ratios at 0-5°N cannot be explained by photochemical formation, but must be of natural origin. On the return journey, the ITCZ was at 6°S and was weak. This explains the very low ozone values of only 4 ppb at times, caused by the photolysis of ozone. The ozone device was housed in the crow's nest, to avoid ship-polluted interference. At later cruises, the instrument was placed near the weather station, because the maintenance in the crow’s nest was impractical and the new air intake at the uppermost railing turned out to be suitable as well. As a precaution, the air pump was changed nine times during the trip. At the end of the last section, the pump wobbled a little, resulting in a five percent loss of production, which could be corrected
title Wet chemical surface ozone measurements during POLARSTERN cruise ANT-I/1 (PS01) in 1982/83
topic ANT-I/1; CT; DATE/TIME; Electrochemical concentration cell (ECC) (Atmannspacher 1971); LATITUDE; LONGITUDE; Ozone; Polarstern; PS01; PS01/1-track; Underway cruise track measurements
url https://doi.org/10.1594/PANGAEA.944260