Wet chemical surface ozone measurements during POLARSTERN cruise ANT-II/1 (PS04) in 1983
Fuente:
PANGAEA
Guardado en:
| Autor principal: | |
|---|---|
| Formato: | Dataset Open Access |
| Lenguaje: | en |
| Publicado: |
PANGAEA
2022
|
| Materias: | |
| Acceso en línea: | |
| Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
| _version_ | 1867168215958814720 |
|---|---|
| author | Winkler, Peter |
| author_facet | Winkler, Peter |
| collection | Datos científicos de ciencias marinas y ambientales |
| contents | The ozone device was operated in the crow's nest to be free of ship interference. This precautionary measure proved to be unnecessary, as parallel measurements with an optical ozone device showed. It even had disadvantages because of the awkward usability and was no longer practiced on later trips. The bubbler was completely replaced once during the trip. The air pump on the ozone device was changed five times as a precaution. The care was provided by Dr. Helas taken over by MPI Mainz. On the outward journey, an ozone minimum was observed in the area of the ITCZ (7°N), as is typical for conditions with high levels of solar radiation and low vertical mixing. Further trace substances (NOx; HNO₃; krypton-85, aerosol) were measured on this trip. |
| format | Dataset Open Access |
| id | pangaea_https___doi_org_10_1594_PANGAEA_944282 |
| institution | PANGAEA |
| language | en |
| publishDate | 2022 |
| publisher | PANGAEA |
| record_format | pangaea |
| spellingShingle | Wet chemical surface ozone measurements during POLARSTERN cruise ANT-II/1 (PS04) in 1983 Winkler, Peter ANT-II/1; CT; DATE/TIME; Electrochemical concentration cell (ECC) (Atmannspacher 1971); LATITUDE; LONGITUDE; Ozone; Polarstern; PS04; PS04/1-track; Underway cruise track measurements The ozone device was operated in the crow's nest to be free of ship interference. This precautionary measure proved to be unnecessary, as parallel measurements with an optical ozone device showed. It even had disadvantages because of the awkward usability and was no longer practiced on later trips. The bubbler was completely replaced once during the trip. The air pump on the ozone device was changed five times as a precaution. The care was provided by Dr. Helas taken over by MPI Mainz. On the outward journey, an ozone minimum was observed in the area of the ITCZ (7°N), as is typical for conditions with high levels of solar radiation and low vertical mixing. Further trace substances (NOx; HNO₃; krypton-85, aerosol) were measured on this trip. |
| title | Wet chemical surface ozone measurements during POLARSTERN cruise ANT-II/1 (PS04) in 1983 |
| topic | ANT-II/1; CT; DATE/TIME; Electrochemical concentration cell (ECC) (Atmannspacher 1971); LATITUDE; LONGITUDE; Ozone; Polarstern; PS04; PS04/1-track; Underway cruise track measurements |
| url | https://doi.org/10.1594/PANGAEA.944282 |