Drilling data at MeBo200 drill site GeoB23234-1, South China Sea

Fuente: PANGAEA
Saved in:
Bibliographic Details
Main Author: Freudenthal, Tim
Format: Dataset Open Access
Language:en
Published: PANGAEA 2022
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867169451418320896
author Freudenthal, Tim
author_facet Freudenthal, Tim
collection Datos científicos de ciencias marinas y ambientales
contents Drilling data at site GeoB23231-1 were collected during operation of the sea floor drill rig MARUM-MeBo200 during research expedition SO266 in November 2018 on the northern part of the summit of Four Way Closure Ridge at the South China. Vertical movements of the drill head are monitored with an electromagnetic encoder type TXN 11551 FD by TWK Supreme Sensoric GmbH. Drilling depth was calculated by summing up the drill head movements with the drill being connected to the drill string. The accuracy of the calculated drilling depth is about 0.1%. Flow rate of the flush water was measured within the pressure line of the flush water pump by using a RN3/32/15SP360 flowmeter by UK Flowtechnik. The accuracy of the measurement is better than 0.2%
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_945431
institution PANGAEA
language en
publishDate 2022
publisher PANGAEA
record_format pangaea
spellingShingle Drilling data at MeBo200 drill site GeoB23234-1, South China Sea
Freudenthal, Tim
Center for Marine Environmental Sciences; DATE/TIME; DEPTH, sediment/rock; Drilling data; Flowmeter RN3/32/15SP360, UK Flowtechnik; Flow rate; GeoB23234-1; MARUM; MeBo200; SO266_34-1; SO266/1; Sonne_2
Drilling data at site GeoB23231-1 were collected during operation of the sea floor drill rig MARUM-MeBo200 during research expedition SO266 in November 2018 on the northern part of the summit of Four Way Closure Ridge at the South China. Vertical movements of the drill head are monitored with an electromagnetic encoder type TXN 11551 FD by TWK Supreme Sensoric GmbH. Drilling depth was calculated by summing up the drill head movements with the drill being connected to the drill string. The accuracy of the calculated drilling depth is about 0.1%. Flow rate of the flush water was measured within the pressure line of the flush water pump by using a RN3/32/15SP360 flowmeter by UK Flowtechnik. The accuracy of the measurement is better than 0.2%
title Drilling data at MeBo200 drill site GeoB23234-1, South China Sea
topic Center for Marine Environmental Sciences; DATE/TIME; DEPTH, sediment/rock; Drilling data; Flowmeter RN3/32/15SP360, UK Flowtechnik; Flow rate; GeoB23234-1; MARUM; MeBo200; SO266_34-1; SO266/1; Sonne_2
url https://doi.org/10.1594/PANGAEA.945431