Magnetic susceptibility and weight, X-ray diffraction, and grain size distribution data for cores KR13-02 PC05 and MR14-E02 PC11, western North Pacific

Fuente: PANGAEA
Salvato in:
Dettagli Bibliografici
Autore principale: Usui, Yoichi
Natura: Dataset Open Access
Lingua:en
Pubblicazione: PANGAEA 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867167680611483648
author Usui, Yoichi
author_facet Usui, Yoichi
collection Datos científicos de ciencias marinas y ambientales
contents Bulk magnetic susceptibility was measured using a Kappabridge (KLY-4 or MFK1, AGICO). Anisotropy of magnetic susceptibility (AMS) was measured using the manufacture's SUFAR software program, and bulk susceptibility was calculated from the AMS tensor. Chemical digestion by citrate-bicarbonate-dithionite, and sodium pyrosulfate fusion to extract eolian feldspar and quartz. XRD analysis was conducted using a diffractometer (MiniFlex II, Rigaku) with Cu Ka radiation. The samples were first dispersed in a 0.2 % sodium hexametaphosphate solution and sonicated for 1h. The dispersed sample was then introduced into a laser diffraction particle size analyzer (Mastersizer 3000E, Malvern Panalytical).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_946878
institution PANGAEA
language en
publishDate 2026
publisher PANGAEA
record_format pangaea
spellingShingle Magnetic susceptibility and weight, X-ray diffraction, and grain size distribution data for cores KR13-02 PC05 and MR14-E02 PC11, western North Pacific
Usui, Yoichi
JSPS KAKENHI; KAKENHI
Bulk magnetic susceptibility was measured using a Kappabridge (KLY-4 or MFK1, AGICO). Anisotropy of magnetic susceptibility (AMS) was measured using the manufacture's SUFAR software program, and bulk susceptibility was calculated from the AMS tensor. Chemical digestion by citrate-bicarbonate-dithionite, and sodium pyrosulfate fusion to extract eolian feldspar and quartz. XRD analysis was conducted using a diffractometer (MiniFlex II, Rigaku) with Cu Ka radiation. The samples were first dispersed in a 0.2 % sodium hexametaphosphate solution and sonicated for 1h. The dispersed sample was then introduced into a laser diffraction particle size analyzer (Mastersizer 3000E, Malvern Panalytical).
title Magnetic susceptibility and weight, X-ray diffraction, and grain size distribution data for cores KR13-02 PC05 and MR14-E02 PC11, western North Pacific
topic JSPS KAKENHI; KAKENHI
url https://doi.org/10.1594/PANGAEA.946878