Uranium-Lead LA-ICPMS analysis of quality control calcite sample WC1
Fuente:
PANGAEA
Gespeichert in:
| 1. Verfasser: | |
|---|---|
| Format: | Dataset Open Access |
| Sprache: | en |
| Veröffentlicht: |
PANGAEA
2024
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1867169453584678912 |
|---|---|
| author | Bouat, Loic |
| author_facet | Bouat, Loic |
| collection | Datos científicos de ciencias marinas y ambientales |
| contents | This data provide all details concerning LA-ICPMS U-Pb analyzis on calcites from the Vendée coast in France. The 3 calcites samples PP5, PN201 and ASN201 come from veins hosted in the sedimentary cover below the unconformity with the Armorican Massif below. The LA-ICPMS U-Pb analyzis were proceed with the GeOHeLiS Platform from Université Rennes 1 (France) using WC1 standard as quality control. |
| format | Dataset Open Access |
| id | pangaea_https___doi_org_10_1594_PANGAEA_948395 |
| institution | PANGAEA |
| language | en |
| publishDate | 2024 |
| publisher | PANGAEA |
| record_format | pangaea |
| spellingShingle | Uranium-Lead LA-ICPMS analysis of quality control calcite sample WC1 Bouat, Loic Age, 206Pb/238U Lead-Uranium; Age, 207Pb/206Pb Lead-Lead; Age, 207Pb/235U Lead-Uranium; Age, dated; Age, dated standard error; Calcite; Correlation coefficient, isotope ratio error; dating; Identification; Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS); Lead-206; Lead-206/Uranium-238 ratio; Lead-206/Uranium-238 ratio, error, relative; Lead-207/Lead-206 ratio; Lead-207/Lead-206 ratio, error, relative; Lead-207/Uranium-235 ratio; Lead-207/Uranium-235 ratio, error, relative; U-Pb dating; Uranium-238; Uranium-238/Lead-206 ratio; Uranium-238/Lead-206 ratio, error, relative; Year of analysis This data provide all details concerning LA-ICPMS U-Pb analyzis on calcites from the Vendée coast in France. The 3 calcites samples PP5, PN201 and ASN201 come from veins hosted in the sedimentary cover below the unconformity with the Armorican Massif below. The LA-ICPMS U-Pb analyzis were proceed with the GeOHeLiS Platform from Université Rennes 1 (France) using WC1 standard as quality control. |
| title | Uranium-Lead LA-ICPMS analysis of quality control calcite sample WC1 |
| topic | Age, 206Pb/238U Lead-Uranium; Age, 207Pb/206Pb Lead-Lead; Age, 207Pb/235U Lead-Uranium; Age, dated; Age, dated standard error; Calcite; Correlation coefficient, isotope ratio error; dating; Identification; Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS); Lead-206; Lead-206/Uranium-238 ratio; Lead-206/Uranium-238 ratio, error, relative; Lead-207/Lead-206 ratio; Lead-207/Lead-206 ratio, error, relative; Lead-207/Uranium-235 ratio; Lead-207/Uranium-235 ratio, error, relative; U-Pb dating; Uranium-238; Uranium-238/Lead-206 ratio; Uranium-238/Lead-206 ratio, error, relative; Year of analysis |
| url | https://doi.org/10.1594/PANGAEA.948395 |