_version_ 1867168510322409472
author Saito, Ryosuke
Wörmer, Lars
Taubner, Heidi
Kaiho, Kunio
Takahashi, Satoshi
Tian, Li
Ikeda, Masayuki
Summons, Roger E
Hinrichs, Kai-Uwe
author_facet Saito, Ryosuke
Wörmer, Lars
Taubner, Heidi
Kaiho, Kunio
Takahashi, Satoshi
Tian, Li
Ikeda, Masayuki
Summons, Roger E
Hinrichs, Kai-Uwe
collection Datos científicos de ciencias marinas y ambientales
contents The non-polar fraction of toluene:MeOH (9:1) extracted sediment samples was analyzed by GC-MS on an Agilent gas chromatograph (GC, 6890) interfaced with an Agilent 5975 mass selective detection (MSD) instrument. A DB-5MS column (60 m × 250 μm × 0.25 μm) was installed with the GC oven. The temperature program was: isothermally at 40 °C for 2 min, ramped to 320 °C at a rate of 4°/min, and then held at this temperature for 22 min.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_952294
institution PANGAEA
language en
publishDate 2022
publisher PANGAEA
record_format pangaea
spellingShingle GC-MS-based PAHs, C2-DBF and hopane ratio in the uppermost Permian Changxing Fm. in the Meishan C section
Saito, Ryosuke
Wörmer, Lars
Taubner, Heidi
Kaiho, Kunio
Takahashi, Satoshi
Tian, Li
Ikeda, Masayuki
Summons, Roger E
Hinrichs, Kai-Uwe
4-ring polycyclic aromatic hydrocarbon, per unit sediment dry mass; 5-ring polycyclic aromatic hydrocarbon, per unit sediment dry mass; 6-ring polycyclic aromatic hydrocarbon, per unit sediment dry mass; 7-ring PAH/5-ring PAH ratio; 7-ring polycyclic aromatic hydrocarbon, per unit sediment dry mass; C2-dibenzofuran, dry sediment; C30 hopane beta alpha/(beta alpha +alpha beta); Calculated; Changxing_formation; dibenzofuran; Distance; Distance, maximum; Distance, minimum; end-Permian mass extinction; GC-MS; GC-MS analysis of the non-polar fraction of extracted sediment powder; HAM; Hammer; hopane; Meishan; Meishan, Zhejiang Province, South China; PAHs; ZOOMecular; Zooming into paleoenvironmental and biogeochemical processes through molecular imaging of biomarker distributions in sediments
The non-polar fraction of toluene:MeOH (9:1) extracted sediment samples was analyzed by GC-MS on an Agilent gas chromatograph (GC, 6890) interfaced with an Agilent 5975 mass selective detection (MSD) instrument. A DB-5MS column (60 m × 250 μm × 0.25 μm) was installed with the GC oven. The temperature program was: isothermally at 40 °C for 2 min, ramped to 320 °C at a rate of 4°/min, and then held at this temperature for 22 min.
title GC-MS-based PAHs, C2-DBF and hopane ratio in the uppermost Permian Changxing Fm. in the Meishan C section
topic 4-ring polycyclic aromatic hydrocarbon, per unit sediment dry mass; 5-ring polycyclic aromatic hydrocarbon, per unit sediment dry mass; 6-ring polycyclic aromatic hydrocarbon, per unit sediment dry mass; 7-ring PAH/5-ring PAH ratio; 7-ring polycyclic aromatic hydrocarbon, per unit sediment dry mass; C2-dibenzofuran, dry sediment; C30 hopane beta alpha/(beta alpha +alpha beta); Calculated; Changxing_formation; dibenzofuran; Distance; Distance, maximum; Distance, minimum; end-Permian mass extinction; GC-MS; GC-MS analysis of the non-polar fraction of extracted sediment powder; HAM; Hammer; hopane; Meishan; Meishan, Zhejiang Province, South China; PAHs; ZOOMecular; Zooming into paleoenvironmental and biogeochemical processes through molecular imaging of biomarker distributions in sediments
url https://doi.org/10.1594/PANGAEA.952294