Experimental investigation of liquid interface stability during the filling of a tank in microgravity

Fuente: PANGAEA
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Govindan, Sesha N C, Dreyer, Michael E
Format: Dataset Open Access
Langue:en
Publié: PANGAEA 2023
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1867171883920654336
author Govindan, Sesha N C
Dreyer, Michael E
author_facet Govindan, Sesha N C
Dreyer, Michael E
collection Datos científicos de ciencias marinas y ambientales
contents The storage of propellants in space as well as the transfer and filling of spacecraft tanks is a prerequisite for future long-term space exploration missions. In this work, the vented filling of a partially filled tank, which is envisioned as a spacecraft tank, was investigated experimentally under compensated gravity in the Bremen Drop Tower. Experiments were performed with a partially filled tank and a test liquid HFE-7500. The drop tower provides 9s of compensated gravity. The shape of the free liquid surface inside a right circular cylinder changes from the normal gravity configuration to a free fall configuration during the test. The fillling was initiated after 3.5s and continued until the end at 9s. The interaction of the incoming liquid jet with the liquid interface was studied for different volumetric flow rates. A stable, but not steady liquid interface was characterized by a deformation due to the incoming liquid jet and the formation of a geyser. The growth of the geyser and the following disintegration into liquid droplets indicated an unstable liquid interface. Subcritical, critical and supercritical regimes of the volumetric flow rates were identified to classify stable and unstable liquid interfaces. The critical Weber number was found to be 1.04, which corresponds to a critical volumetric flow rate of 1.30mL/s. This critical Weber number was compared with the existing literature. Additionally, the behaviour of the liquid interface during the reorientation of the liquid inside the tank was observed.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_956532
institution PANGAEA
language en
publishDate 2023
publisher PANGAEA
record_format pangaea
spellingShingle Experimental investigation of liquid interface stability during the filling of a tank in microgravity
Govindan, Sesha N C
Dreyer, Michael E
Binary Object; Binary Object (File Size); Description; Drop tower experiment; File format; File name; Interface stability; Liquid reorientation; Microgravity; Title; Vented filling; Weber number
The storage of propellants in space as well as the transfer and filling of spacecraft tanks is a prerequisite for future long-term space exploration missions. In this work, the vented filling of a partially filled tank, which is envisioned as a spacecraft tank, was investigated experimentally under compensated gravity in the Bremen Drop Tower. Experiments were performed with a partially filled tank and a test liquid HFE-7500. The drop tower provides 9s of compensated gravity. The shape of the free liquid surface inside a right circular cylinder changes from the normal gravity configuration to a free fall configuration during the test. The fillling was initiated after 3.5s and continued until the end at 9s. The interaction of the incoming liquid jet with the liquid interface was studied for different volumetric flow rates. A stable, but not steady liquid interface was characterized by a deformation due to the incoming liquid jet and the formation of a geyser. The growth of the geyser and the following disintegration into liquid droplets indicated an unstable liquid interface. Subcritical, critical and supercritical regimes of the volumetric flow rates were identified to classify stable and unstable liquid interfaces. The critical Weber number was found to be 1.04, which corresponds to a critical volumetric flow rate of 1.30mL/s. This critical Weber number was compared with the existing literature. Additionally, the behaviour of the liquid interface during the reorientation of the liquid inside the tank was observed.
title Experimental investigation of liquid interface stability during the filling of a tank in microgravity
topic Binary Object; Binary Object (File Size); Description; Drop tower experiment; File format; File name; Interface stability; Liquid reorientation; Microgravity; Title; Vented filling; Weber number
url https://doi.org/10.1594/PANGAEA.956532