Dataset of sediment analyses (pH, electrical conductivity, magnetic susceptibility, loss on ignition, and X-ray fluorescence) from the Deliktaş catchment in the Pergamon micro-region, western Türkiye

Fuente: PANGAEA
Salvato in:
Dettagli Bibliografici
Autori principali: Yang, Xun, Becker, Fabian, Nykamp, Moritz, Schütt, Brigitta
Natura: Dataset Open Access
Lingua:en
Pubblicazione: PANGAEA 2023
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867170119351795712
author Yang, Xun
Becker, Fabian
Nykamp, Moritz
Schütt, Brigitta
author_facet Yang, Xun
Becker, Fabian
Nykamp, Moritz
Schütt, Brigitta
collection Datos científicos de ciencias marinas y ambientales
contents The data support the interpretation of varying sediment facies and the reconstruction of the Holocene alluvial fan dynamics on the Deliktaş catchment in the micro-region of an ancient city Pergamon, west Turkey (Yang et al., under review). This dataset of sediment analyses was collected through the field work in the Deliktaş alluvial fan and laboratory measurements in the Bergama excavation house on October 2021. It comprises the geochemical and element composition of the sediment samples from five sediment sequences (Del-2, Del-3, Del-4, Del-5, and Del-6). Bulk geochemical sediment analyses include pH and electrical conductivity (EC) by a TDS/EC/pH/TEMP meter, mass magnetic susceptibility of low frequency (XLF) by Bartington magnetic susceptibility system (MS2B or MS3 sensor), and loss on ignition on 550 °C (LOI550) by temperature-controlled furnace. In order to test the suitability of the LOI550 for estimating organic matter, we measured the samples of two profiles (AD29 and AD30) from the western lower Bakırçay plain in the sedimentary laboratory in Freie Universität Berlin. The element composition was analyzed using the p-XRF device. The data of sediment samples were recorded in Excel, calculated and illustrated in R software (R Core Team, 2021) and imported into Inkscape software. The sample's depth is simplified by its middle depth. For the XLF measurement, the confidence intervals of the median are estimated by simple quantile bootstrapping (B = 1,000) in R. The sediment parameters of each sediment unit in this study are summarized in median and median absolute deviation (MAD, in brackets) which was calculated in R and they are descripted into 5 classes based on Yang et al. (2023).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_959672
institution PANGAEA
language en
publishDate 2023
publisher PANGAEA
record_format pangaea
spellingShingle Dataset of sediment analyses (pH, electrical conductivity, magnetic susceptibility, loss on ignition, and X-ray fluorescence) from the Deliktaş catchment in the Pergamon micro-region, western Türkiye
Yang, Xun
Becker, Fabian
Nykamp, Moritz
Schütt, Brigitta
AD-29; AD-30; Alluvial fan; Del-2; Del-3; Del-4; Del-5; Del-6; Electrical conductivity; Fieldwork; geomorphodynamics; Holocene; loss on ignition; Magnetic susceptibility; PE10-PhyGeo-FUB_AD-29; PE10-PhyGeo-FUB_AD-30; PE21-PhyGeo-FUB_Del-2; PE21-PhyGeo-FUB_Del-3; PE21-PhyGeo-FUB_Del-4; PE21-PhyGeo-FUB_Del-5; PE21-PhyGeo-FUB_Del-6; Pergamon, Turkey; pH; pXRF; sediment profiles; VCW; Vibracoring, Wacker BHF 30 S, with open cores of 5 cm diameter
The data support the interpretation of varying sediment facies and the reconstruction of the Holocene alluvial fan dynamics on the Deliktaş catchment in the micro-region of an ancient city Pergamon, west Turkey (Yang et al., under review). This dataset of sediment analyses was collected through the field work in the Deliktaş alluvial fan and laboratory measurements in the Bergama excavation house on October 2021. It comprises the geochemical and element composition of the sediment samples from five sediment sequences (Del-2, Del-3, Del-4, Del-5, and Del-6). Bulk geochemical sediment analyses include pH and electrical conductivity (EC) by a TDS/EC/pH/TEMP meter, mass magnetic susceptibility of low frequency (XLF) by Bartington magnetic susceptibility system (MS2B or MS3 sensor), and loss on ignition on 550 °C (LOI550) by temperature-controlled furnace. In order to test the suitability of the LOI550 for estimating organic matter, we measured the samples of two profiles (AD29 and AD30) from the western lower Bakırçay plain in the sedimentary laboratory in Freie Universität Berlin. The element composition was analyzed using the p-XRF device. The data of sediment samples were recorded in Excel, calculated and illustrated in R software (R Core Team, 2021) and imported into Inkscape software. The sample's depth is simplified by its middle depth. For the XLF measurement, the confidence intervals of the median are estimated by simple quantile bootstrapping (B = 1,000) in R. The sediment parameters of each sediment unit in this study are summarized in median and median absolute deviation (MAD, in brackets) which was calculated in R and they are descripted into 5 classes based on Yang et al. (2023).
title Dataset of sediment analyses (pH, electrical conductivity, magnetic susceptibility, loss on ignition, and X-ray fluorescence) from the Deliktaş catchment in the Pergamon micro-region, western Türkiye
topic AD-29; AD-30; Alluvial fan; Del-2; Del-3; Del-4; Del-5; Del-6; Electrical conductivity; Fieldwork; geomorphodynamics; Holocene; loss on ignition; Magnetic susceptibility; PE10-PhyGeo-FUB_AD-29; PE10-PhyGeo-FUB_AD-30; PE21-PhyGeo-FUB_Del-2; PE21-PhyGeo-FUB_Del-3; PE21-PhyGeo-FUB_Del-4; PE21-PhyGeo-FUB_Del-5; PE21-PhyGeo-FUB_Del-6; Pergamon, Turkey; pH; pXRF; sediment profiles; VCW; Vibracoring, Wacker BHF 30 S, with open cores of 5 cm diameter
url https://doi.org/10.1594/PANGAEA.959672