Dissolved concentrations of major elements and water isotopes for water samples from the Rio Bermejo mainstem, tributaries, spring-fed channels, and groundwater wells

Fuente: PANGAEA
Guardado en:
Detalles Bibliográficos
Autores principales: Repasch, Marisa N, Scheingross, Joel S, Cook, Kristen L, Sachse, Dirk, Dosch, Sophia, Orfeo, Oscar
Formato: Dataset Open Access
Lenguaje:en
Publicado: PANGAEA 2023
Materias:
AR15DS-022; AR15DS-025; AR15DS-026; AR15DS-032; AR15DS-033; AR15DS-045; AR15DS-050; AR15DS-052; AR15DS-056; AR15DS-059; AR15DS-063; AR15DS-064; AR16DSXZ; AR16DSXZ-01; AR16DSXZ-02; AR16JS-02; AR16JS-04; AR16JS-05; AR16JS-06; AR16JS-07A; AR16JS-07B; AR17DS-001; AR17DS-002; AR17DS-003; AR17DS-004; AR17DS-005; AR17DS-006; AR17DS-007; AR17JS-01; AR17JS-02; AR17JS-03; AR17JS-04; AR17JS-12; AR17JS-13; AR17JS-15; AR17MR-03; AR17MR-04; AR17MR-05; AR17MR-06; AR17MR-07; AR17MR-08; AR17MR-10; AR17MR-11; AR17MR-12; AR17MR-13; AR17MR-14; AR17MR-15; AR17MR-24; AR17MR-31; AR17MR-35; AR17MR-40; AR17MR-45; AR17MR-50; AR17MR-51; AR17MR-52; AR17MR-56; AR17MR-59; AR19SD-002; AR19SD-008; AR19SD-010; AR19SD-012; AR19SD-014; AR19SD-015; AR19SD-017; AR19SD-018; AR19SD-019; AR19SD-020; AR19SD-021; AR20SD-001; AR20SD-002; AR20SD-003; AR20SD-005; AR20SD-006; AR20SD-008; AR20SD-009; AR20SD-010; AR20SD-013; AR20SD-015; AR20SD-016; AR20SD-018; Argentina; Barium; Barium, uncertainty; Bicarbonate; Bicarbonate, uncertainty; Bromine; Bromine, uncertainty; Bucket, plastic; Calcium; Calcium, uncertainty; Cavity ring-down spectrometer (CRDS), Picarro Inc., L2140-i; channel migration rates; Chlorine; Chlorine, uncertainty; Date/Time of event; Distance; El Colgado; Embarcacion; Event label; Extracted from Sistema Nacional de Información Hídrica; Fluorine; Fluorine, uncertainty; fluvial geomorphology; Foreland basin; General Mansilla; Inductively coupled plasma optical emission spectrometer (ICP-OES), Varian, Varian 720 [Standard: SLRS-5; M212; USGS T187]; correction according to Bickle et al. (2005); Ion Chromatograph, Thermo Fisher, Dionex ICS-11, [Standard: SLRS-5; M212; USGS T187]; correction according to Bickle et al. (2005); Iron; Iron, uncertainty; Latitude of event; Lithium; Lithium, uncertainty; Location; Longitude of event; Magnesium; Magnesium, uncertainty; Manganese; Manganese, uncertainty; Nitrate; Nitrate, uncertainty; Phosphate; Phosphate, uncertainty; PLV_18032016; Potassium; Potassium, uncertainty; Provenance/source; PS14032016; Puerto lavalle; Reserva Natural Formosa; Rio San Francisco; River discharge; river morphometrics; Sample ID; Silicon; Silicon, uncertainty; Sodium; Sodium, uncertainty; StRATEGy; StRATEGy international research training group; Strontium; Strontium, uncertainty; Sulfate; Sulfate, uncertainty; SZ16032016; Total dissolved solids; Total dissolved solids, uncertainty; water chemistry; Water sample; WB; WS; Zinc; Zinc, uncertainty; δ18O, water; δ18O, water, standard deviation; δ Deuterium, water; δ Deuterium, water, standard deviation
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1867170420101218304
author Repasch, Marisa N
Scheingross, Joel S
Cook, Kristen L
Sachse, Dirk
Dosch, Sophia
Orfeo, Oscar
author_facet Repasch, Marisa N
Scheingross, Joel S
Cook, Kristen L
Sachse, Dirk
Dosch, Sophia
Orfeo, Oscar
collection Datos científicos de ciencias marinas y ambientales
contents Water samples were filtered to 0.2 micron prior to measurement. Samples for cation analysis were acidified in the field to pH < 2 using 6N HNO3. Cation concentrations were measured with a Varian 720 inductively coupled plasma optical emission spectrometer (ICP-OES) at the GFZ Helmholtz Laboratory for the Geochemistry of the Earth Surface (HELGES), using SLRS-5 (Saint-Laurent River Surface, National Research Council - Conseil National de Recherches Canada) and USGS M212 and USGS T187 as external standards. We corrected for instrument drift by measuring an internal standard (GFZ-RW1) every 10 samples and we determined measurement uncertainty using calibration curve uncertainty. Anion concentrations were measured with a Dionex ICS1100 Ion Chromatograph, using USGS standards M206 and M212 as external standards for quality control, with uncertainty determined from triplicate analysis. We corrected cation concentrations for cyclic salt inputs following Bickle et al. (2005, doi:10.1016/j.gca.2004.11.019).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_959932
institution PANGAEA
language en
publishDate 2023
publisher PANGAEA
record_format pangaea
spellingShingle Dissolved concentrations of major elements and water isotopes for water samples from the Rio Bermejo mainstem, tributaries, spring-fed channels, and groundwater wells
Repasch, Marisa N
Scheingross, Joel S
Cook, Kristen L
Sachse, Dirk
Dosch, Sophia
Orfeo, Oscar
AR15DS-022; AR15DS-025; AR15DS-026; AR15DS-032; AR15DS-033; AR15DS-045; AR15DS-050; AR15DS-052; AR15DS-056; AR15DS-059; AR15DS-063; AR15DS-064; AR16DSXZ; AR16DSXZ-01; AR16DSXZ-02; AR16JS-02; AR16JS-04; AR16JS-05; AR16JS-06; AR16JS-07A; AR16JS-07B; AR17DS-001; AR17DS-002; AR17DS-003; AR17DS-004; AR17DS-005; AR17DS-006; AR17DS-007; AR17JS-01; AR17JS-02; AR17JS-03; AR17JS-04; AR17JS-12; AR17JS-13; AR17JS-15; AR17MR-03; AR17MR-04; AR17MR-05; AR17MR-06; AR17MR-07; AR17MR-08; AR17MR-10; AR17MR-11; AR17MR-12; AR17MR-13; AR17MR-14; AR17MR-15; AR17MR-24; AR17MR-31; AR17MR-35; AR17MR-40; AR17MR-45; AR17MR-50; AR17MR-51; AR17MR-52; AR17MR-56; AR17MR-59; AR19SD-002; AR19SD-008; AR19SD-010; AR19SD-012; AR19SD-014; AR19SD-015; AR19SD-017; AR19SD-018; AR19SD-019; AR19SD-020; AR19SD-021; AR20SD-001; AR20SD-002; AR20SD-003; AR20SD-005; AR20SD-006; AR20SD-008; AR20SD-009; AR20SD-010; AR20SD-013; AR20SD-015; AR20SD-016; AR20SD-018; Argentina; Barium; Barium, uncertainty; Bicarbonate; Bicarbonate, uncertainty; Bromine; Bromine, uncertainty; Bucket, plastic; Calcium; Calcium, uncertainty; Cavity ring-down spectrometer (CRDS), Picarro Inc., L2140-i; channel migration rates; Chlorine; Chlorine, uncertainty; Date/Time of event; Distance; El Colgado; Embarcacion; Event label; Extracted from Sistema Nacional de Información Hídrica; Fluorine; Fluorine, uncertainty; fluvial geomorphology; Foreland basin; General Mansilla; Inductively coupled plasma optical emission spectrometer (ICP-OES), Varian, Varian 720 [Standard: SLRS-5; M212; USGS T187]; correction according to Bickle et al. (2005); Ion Chromatograph, Thermo Fisher, Dionex ICS-11, [Standard: SLRS-5; M212; USGS T187]; correction according to Bickle et al. (2005); Iron; Iron, uncertainty; Latitude of event; Lithium; Lithium, uncertainty; Location; Longitude of event; Magnesium; Magnesium, uncertainty; Manganese; Manganese, uncertainty; Nitrate; Nitrate, uncertainty; Phosphate; Phosphate, uncertainty; PLV_18032016; Potassium; Potassium, uncertainty; Provenance/source; PS14032016; Puerto lavalle; Reserva Natural Formosa; Rio San Francisco; River discharge; river morphometrics; Sample ID; Silicon; Silicon, uncertainty; Sodium; Sodium, uncertainty; StRATEGy; StRATEGy international research training group; Strontium; Strontium, uncertainty; Sulfate; Sulfate, uncertainty; SZ16032016; Total dissolved solids; Total dissolved solids, uncertainty; water chemistry; Water sample; WB; WS; Zinc; Zinc, uncertainty; δ18O, water; δ18O, water, standard deviation; δ Deuterium, water; δ Deuterium, water, standard deviation
Water samples were filtered to 0.2 micron prior to measurement. Samples for cation analysis were acidified in the field to pH < 2 using 6N HNO3. Cation concentrations were measured with a Varian 720 inductively coupled plasma optical emission spectrometer (ICP-OES) at the GFZ Helmholtz Laboratory for the Geochemistry of the Earth Surface (HELGES), using SLRS-5 (Saint-Laurent River Surface, National Research Council - Conseil National de Recherches Canada) and USGS M212 and USGS T187 as external standards. We corrected for instrument drift by measuring an internal standard (GFZ-RW1) every 10 samples and we determined measurement uncertainty using calibration curve uncertainty. Anion concentrations were measured with a Dionex ICS1100 Ion Chromatograph, using USGS standards M206 and M212 as external standards for quality control, with uncertainty determined from triplicate analysis. We corrected cation concentrations for cyclic salt inputs following Bickle et al. (2005, doi:10.1016/j.gca.2004.11.019).
title Dissolved concentrations of major elements and water isotopes for water samples from the Rio Bermejo mainstem, tributaries, spring-fed channels, and groundwater wells
topic AR15DS-022; AR15DS-025; AR15DS-026; AR15DS-032; AR15DS-033; AR15DS-045; AR15DS-050; AR15DS-052; AR15DS-056; AR15DS-059; AR15DS-063; AR15DS-064; AR16DSXZ; AR16DSXZ-01; AR16DSXZ-02; AR16JS-02; AR16JS-04; AR16JS-05; AR16JS-06; AR16JS-07A; AR16JS-07B; AR17DS-001; AR17DS-002; AR17DS-003; AR17DS-004; AR17DS-005; AR17DS-006; AR17DS-007; AR17JS-01; AR17JS-02; AR17JS-03; AR17JS-04; AR17JS-12; AR17JS-13; AR17JS-15; AR17MR-03; AR17MR-04; AR17MR-05; AR17MR-06; AR17MR-07; AR17MR-08; AR17MR-10; AR17MR-11; AR17MR-12; AR17MR-13; AR17MR-14; AR17MR-15; AR17MR-24; AR17MR-31; AR17MR-35; AR17MR-40; AR17MR-45; AR17MR-50; AR17MR-51; AR17MR-52; AR17MR-56; AR17MR-59; AR19SD-002; AR19SD-008; AR19SD-010; AR19SD-012; AR19SD-014; AR19SD-015; AR19SD-017; AR19SD-018; AR19SD-019; AR19SD-020; AR19SD-021; AR20SD-001; AR20SD-002; AR20SD-003; AR20SD-005; AR20SD-006; AR20SD-008; AR20SD-009; AR20SD-010; AR20SD-013; AR20SD-015; AR20SD-016; AR20SD-018; Argentina; Barium; Barium, uncertainty; Bicarbonate; Bicarbonate, uncertainty; Bromine; Bromine, uncertainty; Bucket, plastic; Calcium; Calcium, uncertainty; Cavity ring-down spectrometer (CRDS), Picarro Inc., L2140-i; channel migration rates; Chlorine; Chlorine, uncertainty; Date/Time of event; Distance; El Colgado; Embarcacion; Event label; Extracted from Sistema Nacional de Información Hídrica; Fluorine; Fluorine, uncertainty; fluvial geomorphology; Foreland basin; General Mansilla; Inductively coupled plasma optical emission spectrometer (ICP-OES), Varian, Varian 720 [Standard: SLRS-5; M212; USGS T187]; correction according to Bickle et al. (2005); Ion Chromatograph, Thermo Fisher, Dionex ICS-11, [Standard: SLRS-5; M212; USGS T187]; correction according to Bickle et al. (2005); Iron; Iron, uncertainty; Latitude of event; Lithium; Lithium, uncertainty; Location; Longitude of event; Magnesium; Magnesium, uncertainty; Manganese; Manganese, uncertainty; Nitrate; Nitrate, uncertainty; Phosphate; Phosphate, uncertainty; PLV_18032016; Potassium; Potassium, uncertainty; Provenance/source; PS14032016; Puerto lavalle; Reserva Natural Formosa; Rio San Francisco; River discharge; river morphometrics; Sample ID; Silicon; Silicon, uncertainty; Sodium; Sodium, uncertainty; StRATEGy; StRATEGy international research training group; Strontium; Strontium, uncertainty; Sulfate; Sulfate, uncertainty; SZ16032016; Total dissolved solids; Total dissolved solids, uncertainty; water chemistry; Water sample; WB; WS; Zinc; Zinc, uncertainty; δ18O, water; δ18O, water, standard deviation; δ Deuterium, water; δ Deuterium, water, standard deviation
url https://doi.org/10.1594/PANGAEA.959932