Temperature and relative humidity in 10 min time resolution measured in the total inlet of the Swiss container during MOSAiC 2019/2020

Fuente: PANGAEA
Guardado en:
Detalles Bibliográficos
Autores principales: Heutte, Benjamin, Beck, Ivo, Quéléver, Lauriane, Jokinen, Tuija, Laurila, Tiia, Schmale, Julia
Formato: Dataset Open Access
Lenguaje:en
Publicado: PANGAEA 2023
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1867171885717913600
author Heutte, Benjamin
Beck, Ivo
Quéléver, Lauriane
Jokinen, Tuija
Laurila, Tiia
Schmale, Julia
author_facet Heutte, Benjamin
Beck, Ivo
Quéléver, Lauriane
Jokinen, Tuija
Laurila, Tiia
Schmale, Julia
collection Datos científicos de ciencias marinas y ambientales
contents This dataset contains the temperature and relative humidity in a bypass to the total inlet, measured during the MOSAiC expedition from October 2019 to September 2020. The measurements were performed in the bypass interstitial inlet of the Swiss container on the D-deck of Research Vessel Polarstern, using a commercial hygrometer model HC2 (Rotronic AG, Bassersdorf, Switzerland). The interstitial inlet had a flow of > 17 L/min and was equipped with a 1 µm cyclone, for sampling interstitial particles only, as opposed to the total inlet (flow of > 15 L/min) which sampled all particles and hydrometeors up to 40 µm in diameter. The total and interstitial inlets were located 3 meters apart and connected to a valve that switched hourly between the two inlets for a targeted set of instruments. The complete instrumental setup inside the Swiss container is presented in Heutte et al. (Submitted), Dada et al. (2022), and Beck et al. (2022). Inside both inlets, the temperature was kept constant around 20 °C and the relative humidity was maintained below 40 %, with a heating system following Global Atmosphere Watch (GAW) standards for aerosol sampling (WMO, 2016). This dataset contains measurements of temperature and relative humidity inside the bypass to the total inlet, averaged to 10 min time resolution (native resolution was 5 min), along with the position of the switching valve (1 = total inlet, 0 = interstitial inlet).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_961007
institution PANGAEA
language en
publishDate 2023
publisher PANGAEA
record_format pangaea
spellingShingle Temperature and relative humidity in 10 min time resolution measured in the total inlet of the Swiss container during MOSAiC 2019/2020
Heutte, Benjamin
Beck, Ivo
Quéléver, Lauriane
Jokinen, Tuija
Laurila, Tiia
Schmale, Julia
aerosol; Arctic aerosol; Arctic Ocean; DATE/TIME; Event label; Humidity, relative; HYGRO; Hygrometer; LATITUDE; LONGITUDE; MOSAiC; MOSAiC_ATMOS; MOSAiC20192020; Multidisciplinary drifting Observatory for the Study of Arctic Climate; North Greenland Sea; Polarstern; PS122/1; PS122/1_1-134; PS122/2; PS122/2_14-139; PS122/3; PS122/3_28-34; PS122/4; PS122/4_43-26; PS122/5; PS122/5_58-33; Status; Temperature, air; Temperature and humidity probe, Rotronic, Hygroclip 2 (HC2)
This dataset contains the temperature and relative humidity in a bypass to the total inlet, measured during the MOSAiC expedition from October 2019 to September 2020. The measurements were performed in the bypass interstitial inlet of the Swiss container on the D-deck of Research Vessel Polarstern, using a commercial hygrometer model HC2 (Rotronic AG, Bassersdorf, Switzerland). The interstitial inlet had a flow of > 17 L/min and was equipped with a 1 µm cyclone, for sampling interstitial particles only, as opposed to the total inlet (flow of > 15 L/min) which sampled all particles and hydrometeors up to 40 µm in diameter. The total and interstitial inlets were located 3 meters apart and connected to a valve that switched hourly between the two inlets for a targeted set of instruments. The complete instrumental setup inside the Swiss container is presented in Heutte et al. (Submitted), Dada et al. (2022), and Beck et al. (2022). Inside both inlets, the temperature was kept constant around 20 °C and the relative humidity was maintained below 40 %, with a heating system following Global Atmosphere Watch (GAW) standards for aerosol sampling (WMO, 2016). This dataset contains measurements of temperature and relative humidity inside the bypass to the total inlet, averaged to 10 min time resolution (native resolution was 5 min), along with the position of the switching valve (1 = total inlet, 0 = interstitial inlet).
title Temperature and relative humidity in 10 min time resolution measured in the total inlet of the Swiss container during MOSAiC 2019/2020
topic aerosol; Arctic aerosol; Arctic Ocean; DATE/TIME; Event label; Humidity, relative; HYGRO; Hygrometer; LATITUDE; LONGITUDE; MOSAiC; MOSAiC_ATMOS; MOSAiC20192020; Multidisciplinary drifting Observatory for the Study of Arctic Climate; North Greenland Sea; Polarstern; PS122/1; PS122/1_1-134; PS122/2; PS122/2_14-139; PS122/3; PS122/3_28-34; PS122/4; PS122/4_43-26; PS122/5; PS122/5_58-33; Status; Temperature, air; Temperature and humidity probe, Rotronic, Hygroclip 2 (HC2)
url https://doi.org/10.1594/PANGAEA.961007