Cloud Condensation Nuclei (CCN) concentrations at 0.2% supersaturation level measured in the Swiss container during MOSAiC 2019/2020

Fuente: PANGAEA
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bergner, Nora, Heutte, Benjamin, Angot, Hélène, Dada, Lubna, Beck, Ivo, Quéléver, Lauriane, Jokinen, Tuija, Laurila, Tiia, Schmale, Julia
Format: Dataset Open Access
Sprache:en
Veröffentlicht: PANGAEA 2023
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1867168520169586688
author Bergner, Nora
Heutte, Benjamin
Angot, Hélène
Dada, Lubna
Beck, Ivo
Quéléver, Lauriane
Jokinen, Tuija
Laurila, Tiia
Schmale, Julia
author_facet Bergner, Nora
Heutte, Benjamin
Angot, Hélène
Dada, Lubna
Beck, Ivo
Quéléver, Lauriane
Jokinen, Tuija
Laurila, Tiia
Schmale, Julia
collection Datos científicos de ciencias marinas y ambientales
contents This dataset contains CCN concentrations at five supersaturation levels, averaged to 1 min time resolution, measured during the year-long Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition from October 2019 to September 2020. The measurements were performed in the Swiss container on the D-deck of Research Vessel Polarstern, using the model CCN-100 from Droplet Measurement Technologies (DMT, Boulder, USA). Detailed description of the measurement principle can be found in e.g. Roberts & Nenes (2005). The instrument was located behind an automated valve, which switched hourly between a total and an interstitial air inlet, with upper cutoff sizes of 40 and 1 µm respectively (Heutte et al., Submitted; Beck et al., 2022; Dada et al., 2022). The measurements were performed in 1-h cycles, with a 0.5 L/min sample flow and a 2 L/min make up flow, where the supersaturations 0.15, 0.2, 0.3, 0.5 and 1.0 % were measured. The supersaturation of 0.15 % is measured for 20 min, as it takes longer to equilibrate, and the remaining supersaturations were measured for 10 min each. The instrument was calibrated in July 2019 before the campaign, and in March and April 2020 during the campaign. Based on the inter-variability of the calculated supersaturation levels during these calibrations, we can expect values ranging from 0.15-0.20, 0.20-0.25, 0.29-0.33, 0.43-0.5, 0.78-1.0 % for the nominal supersaturations of 0.15, 0.2, 0.3, 0.5 and 1.0 %, respectively. The counting error for the CCNC is associated with the error in the optical counting of particles and is about 10 %. Data were removed during the cooling cycle (i.e., the time when the measurement cycle starts again and the temperature is cooled to set the lowest supersaturation), which corresponds roughly to the first 10 min of each hour (so 50 % of the 0.15 % supersaturation period). Additionally, the first minute of the transition between supersaturations was removed before averaging the data to 1 min time resolution. During some time periods, a difference pattern of mean and standard deviation of the measurements between even and odd hours was observed, most probably caused by a persistent pressure drop in the inlet lines, resulting in a proportional reduction of the concentration measurements. For correction, the 1-h arithmetic mean of interstitial inlet measurements and the mean of the two adjacent hours of total inlet measurements were subtracted, and the resulting difference was added as a constant to the data points of the interstitial inlet measurements. The dataset contains a pollution mask for local pollution (predominantly exhaust from the Research Vessel Polarstern) with 0 indicating clean, and 1 indicating polluted periods (Beck et al., 2022; Beck et al., 2022).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_961134
institution PANGAEA
language en
publishDate 2023
publisher PANGAEA
record_format pangaea
spellingShingle Cloud Condensation Nuclei (CCN) concentrations at 0.2% supersaturation level measured in the Swiss container during MOSAiC 2019/2020
Bergner, Nora
Heutte, Benjamin
Angot, Hélène
Dada, Lubna
Beck, Ivo
Quéléver, Lauriane
Jokinen, Tuija
Laurila, Tiia
Schmale, Julia
aerosols; Arctic aerosol; Arctic Ocean; CCNC; cloud condensation nuclei; Cloud Condensation Nuclei Counter; Condensation particle counter; CPC; DATE/TIME; Event label; Flag, pollution; LATITUDE; LONGITUDE; MOSAiC; MOSAiC_ATMOS; MOSAiC20192020; Multidisciplinary drifting Observatory for the Study of Arctic Climate; Particle number; Polarstern; PS122/1; PS122/1_1-83; PS122/2; PS122/2_14-33; PS122/3; PS122/3_28-29
This dataset contains CCN concentrations at five supersaturation levels, averaged to 1 min time resolution, measured during the year-long Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition from October 2019 to September 2020. The measurements were performed in the Swiss container on the D-deck of Research Vessel Polarstern, using the model CCN-100 from Droplet Measurement Technologies (DMT, Boulder, USA). Detailed description of the measurement principle can be found in e.g. Roberts & Nenes (2005). The instrument was located behind an automated valve, which switched hourly between a total and an interstitial air inlet, with upper cutoff sizes of 40 and 1 µm respectively (Heutte et al., Submitted; Beck et al., 2022; Dada et al., 2022). The measurements were performed in 1-h cycles, with a 0.5 L/min sample flow and a 2 L/min make up flow, where the supersaturations 0.15, 0.2, 0.3, 0.5 and 1.0 % were measured. The supersaturation of 0.15 % is measured for 20 min, as it takes longer to equilibrate, and the remaining supersaturations were measured for 10 min each. The instrument was calibrated in July 2019 before the campaign, and in March and April 2020 during the campaign. Based on the inter-variability of the calculated supersaturation levels during these calibrations, we can expect values ranging from 0.15-0.20, 0.20-0.25, 0.29-0.33, 0.43-0.5, 0.78-1.0 % for the nominal supersaturations of 0.15, 0.2, 0.3, 0.5 and 1.0 %, respectively. The counting error for the CCNC is associated with the error in the optical counting of particles and is about 10 %. Data were removed during the cooling cycle (i.e., the time when the measurement cycle starts again and the temperature is cooled to set the lowest supersaturation), which corresponds roughly to the first 10 min of each hour (so 50 % of the 0.15 % supersaturation period). Additionally, the first minute of the transition between supersaturations was removed before averaging the data to 1 min time resolution. During some time periods, a difference pattern of mean and standard deviation of the measurements between even and odd hours was observed, most probably caused by a persistent pressure drop in the inlet lines, resulting in a proportional reduction of the concentration measurements. For correction, the 1-h arithmetic mean of interstitial inlet measurements and the mean of the two adjacent hours of total inlet measurements were subtracted, and the resulting difference was added as a constant to the data points of the interstitial inlet measurements. The dataset contains a pollution mask for local pollution (predominantly exhaust from the Research Vessel Polarstern) with 0 indicating clean, and 1 indicating polluted periods (Beck et al., 2022; Beck et al., 2022).
title Cloud Condensation Nuclei (CCN) concentrations at 0.2% supersaturation level measured in the Swiss container during MOSAiC 2019/2020
topic aerosols; Arctic aerosol; Arctic Ocean; CCNC; cloud condensation nuclei; Cloud Condensation Nuclei Counter; Condensation particle counter; CPC; DATE/TIME; Event label; Flag, pollution; LATITUDE; LONGITUDE; MOSAiC; MOSAiC_ATMOS; MOSAiC20192020; Multidisciplinary drifting Observatory for the Study of Arctic Climate; Particle number; Polarstern; PS122/1; PS122/1_1-83; PS122/2; PS122/2_14-33; PS122/3; PS122/3_28-29
url https://doi.org/10.1594/PANGAEA.961134