Saved in:
Bibliographic Details
Main Authors: Salganik, Evgenii, Hoppmann, Mario, Scholz, Daniel, Haapala, Jari, Matero, Ilkka
Format: Dataset Open Access
Language:en
Published: PANGAEA 2023
Subjects:
Online Access:https://doi.org/10.1594/PANGAEA.962449
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867169466364723200
author Salganik, Evgenii
Hoppmann, Mario
Scholz, Daniel
Haapala, Jari
Matero, Ilkka
author_facet Salganik, Evgenii
Hoppmann, Mario
Scholz, Daniel
Haapala, Jari
Matero, Ilkka
collection Datos científicos de ciencias marinas y ambientales
contents Temperature and heating-induced temperature were measured along a chain of thermistors. Digital Thermistor Chain DTC15 is an autonomous instrument that was installed on drifting sea ice in the Arctic Ocean during the MOSAiC expedition on 07 November 2019. The thermistor chain was 4.16 m long and included sensors with a regular spacing of 2 cm. The resulting time series describes the evolution of temperature during the heating cycle of 20 s and after the heating cycle during the following 40 s as a function of geographic position (GPS), depth, and time between 05 November 2019 and 07 January 2020 in sample intervals of 6 hours. It also contains manually estimated positions of air-snow, snow-ice, and ice-water interfaces. The DTC was installed in the deformed second-year ice ridge next to RV Polarstern and remote sensing site RS1.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_962449
institution PANGAEA
language en
publishDate 2023
publisher PANGAEA
record_format pangaea
spellingShingle Temperature difference after the heating cycle from the sea ice mass balance buoy DTC15 during MOSAiC 2019/2020
Salganik, Evgenii
Hoppmann, Mario
Scholz, Daniel
Haapala, Jari
Matero, Ilkka
autonomous platform; buoy; DATE/TIME; Digital thermistor chain; DTC; DTC15; Ice mass balance; LATITUDE; LONGITUDE; MOSAiC; MOSAiC20192020; Multidisciplinary drifting Observatory for the Study of Arctic Climate; Polarstern; Position; PS122/1; PS122/1_1-120; Temperature; Temperature, difference
Temperature and heating-induced temperature were measured along a chain of thermistors. Digital Thermistor Chain DTC15 is an autonomous instrument that was installed on drifting sea ice in the Arctic Ocean during the MOSAiC expedition on 07 November 2019. The thermistor chain was 4.16 m long and included sensors with a regular spacing of 2 cm. The resulting time series describes the evolution of temperature during the heating cycle of 20 s and after the heating cycle during the following 40 s as a function of geographic position (GPS), depth, and time between 05 November 2019 and 07 January 2020 in sample intervals of 6 hours. It also contains manually estimated positions of air-snow, snow-ice, and ice-water interfaces. The DTC was installed in the deformed second-year ice ridge next to RV Polarstern and remote sensing site RS1.
title Temperature difference after the heating cycle from the sea ice mass balance buoy DTC15 during MOSAiC 2019/2020
topic autonomous platform; buoy; DATE/TIME; Digital thermistor chain; DTC; DTC15; Ice mass balance; LATITUDE; LONGITUDE; MOSAiC; MOSAiC20192020; Multidisciplinary drifting Observatory for the Study of Arctic Climate; Polarstern; Position; PS122/1; PS122/1_1-120; Temperature; Temperature, difference
url https://doi.org/10.1594/PANGAEA.962449