_version_ 1867171887613739008
author Steen-Larsen, Hans Christian
Sveinbjörnsdottir, Árný E
Ólafsdóttir, Rosa
Behrens, Melanie
Faber, Anne-Katrine
Freitag, Johannes
Hoffmann, Andrew
Hörhold, Maria
Kahle, Emma
Kipfstuhl, Sepp
Madsen, Martin V
Meyer, Hannah
Town, Michael S
Vladimirova, Diana
Wahl, Sonja
Zolles, Tobias
Zuhr, Alexandra
author_facet Steen-Larsen, Hans Christian
Sveinbjörnsdottir, Árný E
Ólafsdóttir, Rosa
Behrens, Melanie
Faber, Anne-Katrine
Freitag, Johannes
Hoffmann, Andrew
Hörhold, Maria
Kahle, Emma
Kipfstuhl, Sepp
Madsen, Martin V
Meyer, Hannah
Town, Michael S
Vladimirova, Diana
Wahl, Sonja
Zolles, Tobias
Zuhr, Alexandra
collection Datos científicos de ciencias marinas y ambientales
contents Throughout the summer seasons 2017 to 2019 snow profiles were taken repeatedly. The sample positions are aligned along a 300 m wind-parallel transect at the EastGRIP ice core deep drilling site. The snow was collected at 6 positions with a 20 – 50 m spacing. Snow was sampled using carbon fiber tubes of 1-m length that were pushed gently into the snow. A maximum compaction of 1 cm was observed during extraction. The snow cores were carefully removed from the carbon fiber tubes on the cutting table. The core was then cut into slices of 1 cm thickness for the upper 10 cm and 2 cm thickness for the lower 90 cm. The samples were placed into Whirl-Pak® bags and closed airtight. The samples were shipped frozen to the Alfred-Wegener-Institut and stored at -25 °C. Prior to measurements, the samples were melted in the sample bags at room temperature. For the measurement of the isotopic composition, the instrument Picarro L2130-i were used. The measurement set-up followed the Van-Geldern protocol (Van Geldern and Barth, 2012). Each sample was injected 4 times unless otherwise noted in the comment column. As a measure of accuracy, we calculated the combined standard uncertainty (Magnusson, et al., 2017) including the long-term reproducibility and bias of our laboratory by measuring a quality check standard in each measurement run and including the uncertainty of the certified standards. The combined uncertainty for δ18O is 0.11 ‰ and for δ2H is 0.8 ‰. Deuterium excess is calculated as both 1) d = dD - 8*d18O; (Merlivat and Jouzel, 1979) and 2) dln = ln(dD + 1) - 8.47(ln(d18O+1)) - 28.5(ln(d18O+1))2; (Uemura et al., 2012).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_963834
institution PANGAEA
language en
publishDate 2024
publisher PANGAEA
record_format pangaea
spellingShingle Snow Profiles of stable water isotopes at the EastGRIP deep drilling site, summer seasons 2017 - 2019
Steen-Larsen, Hans Christian
Sveinbjörnsdottir, Árný E
Ólafsdóttir, Rosa
Behrens, Melanie
Faber, Anne-Katrine
Freitag, Johannes
Hoffmann, Andrew
Hörhold, Maria
Kahle, Emma
Kipfstuhl, Sepp
Madsen, Martin V
Meyer, Hannah
Town, Michael S
Vladimirova, Diana
Wahl, Sonja
Zolles, Tobias
Zuhr, Alexandra
According to Merlivat and Jouzel (1979); According to Uemura et al. (2012); Cavity ring-down spectroscopy (CRDS) isotopic water analyzer, Picarro Inc., L2130-i; DATE/TIME; DEPTH, ice/snow; Deuterium excess; East Greenland Ice-core Project; EastGRIP; EastGRIP_transect; EGRIP; Greenland; ln-Deuterium excess; Position; Signals from the Surface Snow: Post-Depositional Processes Controlling the Ice Core Isotopic Fingerprint; SNOW; Snow/ice sample; snow-air exchange; SNOWISO; snow profiles; stable water isotopes; δ18O, water; δ Deuterium, water
Throughout the summer seasons 2017 to 2019 snow profiles were taken repeatedly. The sample positions are aligned along a 300 m wind-parallel transect at the EastGRIP ice core deep drilling site. The snow was collected at 6 positions with a 20 – 50 m spacing. Snow was sampled using carbon fiber tubes of 1-m length that were pushed gently into the snow. A maximum compaction of 1 cm was observed during extraction. The snow cores were carefully removed from the carbon fiber tubes on the cutting table. The core was then cut into slices of 1 cm thickness for the upper 10 cm and 2 cm thickness for the lower 90 cm. The samples were placed into Whirl-Pak® bags and closed airtight. The samples were shipped frozen to the Alfred-Wegener-Institut and stored at -25 °C. Prior to measurements, the samples were melted in the sample bags at room temperature. For the measurement of the isotopic composition, the instrument Picarro L2130-i were used. The measurement set-up followed the Van-Geldern protocol (Van Geldern and Barth, 2012). Each sample was injected 4 times unless otherwise noted in the comment column. As a measure of accuracy, we calculated the combined standard uncertainty (Magnusson, et al., 2017) including the long-term reproducibility and bias of our laboratory by measuring a quality check standard in each measurement run and including the uncertainty of the certified standards. The combined uncertainty for δ18O is 0.11 ‰ and for δ2H is 0.8 ‰. Deuterium excess is calculated as both 1) d = dD - 8*d18O; (Merlivat and Jouzel, 1979) and 2) dln = ln(dD + 1) - 8.47(ln(d18O+1)) - 28.5(ln(d18O+1))2; (Uemura et al., 2012).
title Snow Profiles of stable water isotopes at the EastGRIP deep drilling site, summer seasons 2017 - 2019
topic According to Merlivat and Jouzel (1979); According to Uemura et al. (2012); Cavity ring-down spectroscopy (CRDS) isotopic water analyzer, Picarro Inc., L2130-i; DATE/TIME; DEPTH, ice/snow; Deuterium excess; East Greenland Ice-core Project; EastGRIP; EastGRIP_transect; EGRIP; Greenland; ln-Deuterium excess; Position; Signals from the Surface Snow: Post-Depositional Processes Controlling the Ice Core Isotopic Fingerprint; SNOW; Snow/ice sample; snow-air exchange; SNOWISO; snow profiles; stable water isotopes; δ18O, water; δ Deuterium, water
url https://doi.org/10.1594/PANGAEA.963834