Isotope values obtained along cores MD-1 and MD-3 in florida mangrove diebacks

Fuente: PANGAEA
Salvato in:
Dettagli Bibliografici
Autore principale: Cohen, Marcelo Cancela Lisboa
Natura: Dataset Open Access
Lingua:en
Pubblicazione: PANGAEA 2024
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867171330911109120
author Cohen, Marcelo Cancela Lisboa
author_facet Cohen, Marcelo Cancela Lisboa
collection Datos científicos de ciencias marinas y ambientales
contents Samples (5–60 mg, 5 cm interval) were treated with 4% HCl to eliminate carbonate, washed with distilled water (pH 6), and dried at 50°C. Total organic carbon was determined at the Stable Isotope Laboratory of the Center for Nuclear Energy in Agriculture/University of São Paulo (CENA/USP). Results are presented in percentages of dry weight, with precision of 0.09% (Total Organic Carbon - TOC). The C/N data are presented as molar ratio. The organic matter δ13C values are presented as δ13Corg (VPDB standard) with precision of ±0.2‰.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_965039
institution PANGAEA
language en
publishDate 2024
publisher PANGAEA
record_format pangaea
spellingShingle Isotope values obtained along cores MD-1 and MD-3 in florida mangrove diebacks
Cohen, Marcelo Cancela Lisboa
Carbon, organic, total; Carbon, organic, total/Nitrogen, total ratio; carbon isotope; Date/Time of event; Depth, bottom/max; DEPTH, sediment/rock; Depth, top/min; dieback; Event label; Florida; Latitude of event; Longitude of event; mangrove; MD-1; MD-3; Nitrogen, total; PUC; Push corer; δ13C, organic matter
Samples (5–60 mg, 5 cm interval) were treated with 4% HCl to eliminate carbonate, washed with distilled water (pH 6), and dried at 50°C. Total organic carbon was determined at the Stable Isotope Laboratory of the Center for Nuclear Energy in Agriculture/University of São Paulo (CENA/USP). Results are presented in percentages of dry weight, with precision of 0.09% (Total Organic Carbon - TOC). The C/N data are presented as molar ratio. The organic matter δ13C values are presented as δ13Corg (VPDB standard) with precision of ±0.2‰.
title Isotope values obtained along cores MD-1 and MD-3 in florida mangrove diebacks
topic Carbon, organic, total; Carbon, organic, total/Nitrogen, total ratio; carbon isotope; Date/Time of event; Depth, bottom/max; DEPTH, sediment/rock; Depth, top/min; dieback; Event label; Florida; Latitude of event; Longitude of event; mangrove; MD-1; MD-3; Nitrogen, total; PUC; Push corer; δ13C, organic matter
url https://doi.org/10.1594/PANGAEA.965039