_version_ 1867171333339611136
author Opfergelt, Sophie
Gaspard, François
Hirst, Catherine
Monin, Laurence
Juhls, Bennet
Morgenstern, Anne
Overduin, Pier Paul
author_facet Opfergelt, Sophie
Gaspard, François
Hirst, Catherine
Monin, Laurence
Juhls, Bennet
Morgenstern, Anne
Overduin, Pier Paul
collection Datos científicos de ciencias marinas y ambientales
contents We collected water samples from the river surface in the center of the Olenekskaya Channel near Samoylov Island using a pre-rinsed HDPE 1 L bottle. During the open water period (June to October), water was sampled from a small boat, and during ice-covered period (November to May), through a hole drilled through the river ice. Some samples during the river ice break-up (between May and June) as well as some samples during the ice freeze-up in October were taken from the shore due to the inaccessibility of a more centered location on the river channel. Water samples were filtered through a 0.45 μm cellulose acetate filter (which had been rinsed with 20 ml sample water) for Ge concentration and Si isotope composition measurements. The Ge concentration was determined by ICP-mass spectrometry (ICP-MS, ICAPQ Thermo Fisher Scientific, Earth & Life Institute, UCLouvain, Belgium). The detection limit for Ge is 0.04 nM and the analytical precision of the measurement is ± 8% for Ge concentrations < 0.013 nM and ± 4% for Ge concentrations > 0.013 nM. The germanium to silicon ratio was calculated using the silicon concentration available form Juhls et al 2020 (https://doi.org/10.1594/PANGAEA.913197). The standard deviation (SD) on Ge/Si ratio determination is 10%. The silicon isotope composition (δ30Si) was analyzed by MC-ICP-MS (Neptune Plus™ High Resolution Multicollector ICP-MS, Thermo Fisher Scientific, Earth & Life Institute, UCLouvain, Belgium) in wet plasma mode after Si separation using a two-stages column chemistry procedure using an anion exchange resin (Biorad AG MP-1) followed by a cation exchange resin (Biorad AG50W-X12). The instrumental mass bias was corrected using the standard-sample bracketing technique and an external Mg doping. The δ30Si compositions are expressed in relative deviations of 30Si/28Si ratio from the NBS-28 reference standard using the δ-notation (‰) as follows: δ30Si = [(30Si/28Si)sample/(30Si/28Si)NBS-28 -1] × 1000. Each single δ-value represents one sample run and two bracketing standards. The δ30Si values are reported as the mean of isotopic analyses from multiple analytical sessions at least in duplicate (± SD).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_967438
institution PANGAEA
language en
publishDate 2024
publisher PANGAEA
record_format pangaea
spellingShingle Silicon isotope composition and Ge/Si ratio of Lena River water from 20.04.2018 (#1) to 28.03.2019 (#77)
Opfergelt, Sophie
Gaspard, François
Hirst, Catherine
Monin, Laurence
Juhls, Bennet
Morgenstern, Anne
Overduin, Pier Paul
AWI Arctic Land Expedition; biogeochemistry; Comment; DATE/TIME; DEPTH, water; Germanium; Germanium/Silicon ratio; Germanium/Silicon ratio, standard deviation; germanium to silicon ratio; Identification; Inductively coupled plasma mass spectrometer (ICP-MS), ThermoFisher Scientific, Neptune Plus; Lena 2018; Lena 2019; Mass spectrometer (ICP-QMS), Thermo Scientific, iCap Q; Olenekskaya_Ch; RIVER; RU-Land_2018_Lena; RU-Land_2018_Lena_Olenekskaya; RU-Land_2019_Lena; RU-Land_2019_Lena_Olenekskaya; Sampling river; Silicon isotopes; δ30Si; δ30Si, standard deviation
We collected water samples from the river surface in the center of the Olenekskaya Channel near Samoylov Island using a pre-rinsed HDPE 1 L bottle. During the open water period (June to October), water was sampled from a small boat, and during ice-covered period (November to May), through a hole drilled through the river ice. Some samples during the river ice break-up (between May and June) as well as some samples during the ice freeze-up in October were taken from the shore due to the inaccessibility of a more centered location on the river channel. Water samples were filtered through a 0.45 μm cellulose acetate filter (which had been rinsed with 20 ml sample water) for Ge concentration and Si isotope composition measurements. The Ge concentration was determined by ICP-mass spectrometry (ICP-MS, ICAPQ Thermo Fisher Scientific, Earth & Life Institute, UCLouvain, Belgium). The detection limit for Ge is 0.04 nM and the analytical precision of the measurement is ± 8% for Ge concentrations < 0.013 nM and ± 4% for Ge concentrations > 0.013 nM. The germanium to silicon ratio was calculated using the silicon concentration available form Juhls et al 2020 (https://doi.org/10.1594/PANGAEA.913197). The standard deviation (SD) on Ge/Si ratio determination is 10%. The silicon isotope composition (δ30Si) was analyzed by MC-ICP-MS (Neptune Plus™ High Resolution Multicollector ICP-MS, Thermo Fisher Scientific, Earth & Life Institute, UCLouvain, Belgium) in wet plasma mode after Si separation using a two-stages column chemistry procedure using an anion exchange resin (Biorad AG MP-1) followed by a cation exchange resin (Biorad AG50W-X12). The instrumental mass bias was corrected using the standard-sample bracketing technique and an external Mg doping. The δ30Si compositions are expressed in relative deviations of 30Si/28Si ratio from the NBS-28 reference standard using the δ-notation (‰) as follows: δ30Si = [(30Si/28Si)sample/(30Si/28Si)NBS-28 -1] × 1000. Each single δ-value represents one sample run and two bracketing standards. The δ30Si values are reported as the mean of isotopic analyses from multiple analytical sessions at least in duplicate (± SD).
title Silicon isotope composition and Ge/Si ratio of Lena River water from 20.04.2018 (#1) to 28.03.2019 (#77)
topic AWI Arctic Land Expedition; biogeochemistry; Comment; DATE/TIME; DEPTH, water; Germanium; Germanium/Silicon ratio; Germanium/Silicon ratio, standard deviation; germanium to silicon ratio; Identification; Inductively coupled plasma mass spectrometer (ICP-MS), ThermoFisher Scientific, Neptune Plus; Lena 2018; Lena 2019; Mass spectrometer (ICP-QMS), Thermo Scientific, iCap Q; Olenekskaya_Ch; RIVER; RU-Land_2018_Lena; RU-Land_2018_Lena_Olenekskaya; RU-Land_2019_Lena; RU-Land_2019_Lena_Olenekskaya; Sampling river; Silicon isotopes; δ30Si; δ30Si, standard deviation
url https://doi.org/10.1594/PANGAEA.967438