Annual concentrations of phthalic acid esters (PAEs) in the North West Indo-Gangetic Plain (NWIGP)
Fuente:
PANGAEA
Gespeichert in:
| Hauptverfasser: | , , , , |
|---|---|
| Format: | Dataset Open Access |
| Sprache: | en |
| Veröffentlicht: |
PANGAEA
2024
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1867169161764929536 |
|---|---|
| author | Boggarapu Praphulla, Chandra Patnana, Durga Prasad Chaudhary, Pooja Sinha, Baerbel Sinha, Vinayak |
| author_facet | Boggarapu Praphulla, Chandra Patnana, Durga Prasad Chaudhary, Pooja Sinha, Baerbel Sinha, Vinayak |
| collection | Datos científicos de ciencias marinas y ambientales |
| contents | Measurements of daily average concentrations of 6 PAEs (dimethyl phthalate (DMP), diethyl phthalate (DEP), benzyl butyl phthalate (BBP), dibutyl phthalate (DBP), bis (2-ethyl hexyl) phthalate (DEHP), bis(2-ethylhexyl) adipate (DEHA)) are reported from a regionally representative sub-urban site in the North West Indo-Gangetic Plain (NWIGP). Samples were collected on prebaked quartz filters (Pall TissuquartzTM filters, 2500 QAT-UP, 47 mm diameter, 2 μm pore size) at a flow rate of 6.7 L min-1 for 24 hours (10:00 AM to following day 10: 00AM, IST) using the Speciation Aerosol Sampling System (SASS, Met One Instruments Inc., OR, USA) installed on the rooftop (80 feet above ground level) of the Academic Building-2 (30.667°N, 76.729°E), Indian Institute of Science Education and Research, Mohali, India. A total of 31 samples were collected between 13 April 2019 to 25 February 2020. After the sample collection, quartz filters were placed in aluminum foil layered petri slides, sealed with parafilm and stored at 4°C prior to chemical analysis with LC-ESI-MS/MS (Liquid Chromatography – Electrospray Ionization – Tandem Mass Spectrometer) housed at Central Research Instruments Facility (14.1670°N, 77.8091°E) at Sri Sathya Sai Institute of Higher Learning (SSSIHL), Puttaparthi, Andhra Pradesh, India. |
| format | Dataset Open Access |
| id | pangaea_https___doi_org_10_1594_PANGAEA_971316 |
| institution | PANGAEA |
| language | en |
| publishDate | 2024 |
| publisher | PANGAEA |
| record_format | pangaea |
| spellingShingle | Annual concentrations of phthalic acid esters (PAEs) in the North West Indo-Gangetic Plain (NWIGP) Boggarapu Praphulla, Chandra Patnana, Durga Prasad Chaudhary, Pooja Sinha, Baerbel Sinha, Vinayak Bis(2-ethylhexyl) adipate; Bis(2-ethylhexyl) adipate, standard deviation; Bis(2-ethylhexyl) phthalate; Bis(2-ethylhexyl) phthalate, standard deviation; Butyl benzyl phthalate; Butyl benzyl phthalate, standard deviation; DATE/TIME; Dibutyl phthalate; Dibutyl phthalate, standard deviation; Diethyl phthalate; Diethyl phthalate, standard deviation; Dimethyl phthalate; Dimethyl phthalate, standard deviation; HAND; India; Liquid chromatography electrospray ionization-tandemmass spectrometry system (LC-ESI-MS/MS); North West Indo-Gangetic Plain; NWIGP; PAEs; PAHs; Sampling by hand Measurements of daily average concentrations of 6 PAEs (dimethyl phthalate (DMP), diethyl phthalate (DEP), benzyl butyl phthalate (BBP), dibutyl phthalate (DBP), bis (2-ethyl hexyl) phthalate (DEHP), bis(2-ethylhexyl) adipate (DEHA)) are reported from a regionally representative sub-urban site in the North West Indo-Gangetic Plain (NWIGP). Samples were collected on prebaked quartz filters (Pall TissuquartzTM filters, 2500 QAT-UP, 47 mm diameter, 2 μm pore size) at a flow rate of 6.7 L min-1 for 24 hours (10:00 AM to following day 10: 00AM, IST) using the Speciation Aerosol Sampling System (SASS, Met One Instruments Inc., OR, USA) installed on the rooftop (80 feet above ground level) of the Academic Building-2 (30.667°N, 76.729°E), Indian Institute of Science Education and Research, Mohali, India. A total of 31 samples were collected between 13 April 2019 to 25 February 2020. After the sample collection, quartz filters were placed in aluminum foil layered petri slides, sealed with parafilm and stored at 4°C prior to chemical analysis with LC-ESI-MS/MS (Liquid Chromatography – Electrospray Ionization – Tandem Mass Spectrometer) housed at Central Research Instruments Facility (14.1670°N, 77.8091°E) at Sri Sathya Sai Institute of Higher Learning (SSSIHL), Puttaparthi, Andhra Pradesh, India. |
| title | Annual concentrations of phthalic acid esters (PAEs) in the North West Indo-Gangetic Plain (NWIGP) |
| topic | Bis(2-ethylhexyl) adipate; Bis(2-ethylhexyl) adipate, standard deviation; Bis(2-ethylhexyl) phthalate; Bis(2-ethylhexyl) phthalate, standard deviation; Butyl benzyl phthalate; Butyl benzyl phthalate, standard deviation; DATE/TIME; Dibutyl phthalate; Dibutyl phthalate, standard deviation; Diethyl phthalate; Diethyl phthalate, standard deviation; Dimethyl phthalate; Dimethyl phthalate, standard deviation; HAND; India; Liquid chromatography electrospray ionization-tandemmass spectrometry system (LC-ESI-MS/MS); North West Indo-Gangetic Plain; NWIGP; PAEs; PAHs; Sampling by hand |
| url | https://doi.org/10.1594/PANGAEA.971316 |