COALA-2020: Measurements of aerosol composition by ACSM at Cataract Scout Park, NSW, January-March 2020

Fuente: PANGAEA
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Humphries, Ruhi S, Keywood, Melita D, Paton-Walsh, Clare, Naylor, Travis A, Simmons, Jack B, Ramirez-Gamboa, Jhonathan, Dang, Quang Phuc, Sutresna, Adhitya
Format: Dataset Open Access
Sprache:en
Veröffentlicht: PANGAEA 2024
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1867169163316822016
author Humphries, Ruhi S
Keywood, Melita D
Paton-Walsh, Clare
Naylor, Travis A
Simmons, Jack B
Ramirez-Gamboa, Jhonathan
Dang, Quang Phuc
Sutresna, Adhitya
author_facet Humphries, Ruhi S
Keywood, Melita D
Paton-Walsh, Clare
Naylor, Travis A
Simmons, Jack B
Ramirez-Gamboa, Jhonathan
Dang, Quang Phuc
Sutresna, Adhitya
collection Datos científicos de ciencias marinas y ambientales
contents Measurements of aerosol chemical composition were captured using a Time-of-Flight Aerosol Chemical Speciation Monitor (Aerodyne Research Inc., Billerica, MA, USA). Measurements were taken at Cataract Scout Park, Appin, N.S.W. (34°14'42.29S 150°49'24.97E) from a common aerosol inlet manifold 5.13 m above ground level as part of the Characterizing Organics and Aerosol Loading over Australia (COALA-2020) campaign. Data processing was handled by the native Aerodyne software (Tofware v3.2.40210). Measurements were taken at 10-minute time resolution and down sampled to 1-minute means, as reported here. Down sampling occurred using cubic spline interpolation. The ACSM is sensitive to aerosol in the 40 – 1000 nm vacuum aerodynamic diameter range and drew sample air from the common aerosol bypass inlet at a flow rate of 85 mL min-1. Sampled air was dried using a Nafion dryer to less than 40% RH before sampling. Aerosol mass concentrations of organics, chloride, ammonium, nitrate and sulphate were retrieved. Reported errors are calculated using Tofware and are based on the number of counts recorded at each mass value and takes into account the subtraction of the background signal from the sample signal. Note however that noting the ion counts are determined from a measurement of current so that the uncertainty associated with converting the ampere signal to ion counts is also accounted for in the uncertainty calculation.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_973272
institution PANGAEA
language en
publishDate 2024
publisher PANGAEA
record_format pangaea
spellingShingle COALA-2020: Measurements of aerosol composition by ACSM at Cataract Scout Park, NSW, January-March 2020
Humphries, Ruhi S
Keywood, Melita D
Paton-Walsh, Clare
Naylor, Travis A
Simmons, Jack B
Ramirez-Gamboa, Jhonathan
Dang, Quang Phuc
Sutresna, Adhitya
ACSM; aerosol composition; Ammonium; Ammonium, standard error; Appin, Australia; biomass burning; Cataract_scout_park; Characterizing Organics and Aerosol Loading over Australia; Chloride; Chloride, standard error; COALA; COALA-2020; DATE/TIME; HEIGHT above ground; MULT; Multiple investigations; Nitrate; Nitrate, standard error; Organics, aerosol; Organics, aerosol, standard error; Sulfate; Sulfate, standard error; Time-of-Flight Aerosol Chemical Speciation Monitor, Aerodyne Research
Measurements of aerosol chemical composition were captured using a Time-of-Flight Aerosol Chemical Speciation Monitor (Aerodyne Research Inc., Billerica, MA, USA). Measurements were taken at Cataract Scout Park, Appin, N.S.W. (34°14'42.29S 150°49'24.97E) from a common aerosol inlet manifold 5.13 m above ground level as part of the Characterizing Organics and Aerosol Loading over Australia (COALA-2020) campaign. Data processing was handled by the native Aerodyne software (Tofware v3.2.40210). Measurements were taken at 10-minute time resolution and down sampled to 1-minute means, as reported here. Down sampling occurred using cubic spline interpolation. The ACSM is sensitive to aerosol in the 40 – 1000 nm vacuum aerodynamic diameter range and drew sample air from the common aerosol bypass inlet at a flow rate of 85 mL min-1. Sampled air was dried using a Nafion dryer to less than 40% RH before sampling. Aerosol mass concentrations of organics, chloride, ammonium, nitrate and sulphate were retrieved. Reported errors are calculated using Tofware and are based on the number of counts recorded at each mass value and takes into account the subtraction of the background signal from the sample signal. Note however that noting the ion counts are determined from a measurement of current so that the uncertainty associated with converting the ampere signal to ion counts is also accounted for in the uncertainty calculation.
title COALA-2020: Measurements of aerosol composition by ACSM at Cataract Scout Park, NSW, January-March 2020
topic ACSM; aerosol composition; Ammonium; Ammonium, standard error; Appin, Australia; biomass burning; Cataract_scout_park; Characterizing Organics and Aerosol Loading over Australia; Chloride; Chloride, standard error; COALA; COALA-2020; DATE/TIME; HEIGHT above ground; MULT; Multiple investigations; Nitrate; Nitrate, standard error; Organics, aerosol; Organics, aerosol, standard error; Sulfate; Sulfate, standard error; Time-of-Flight Aerosol Chemical Speciation Monitor, Aerodyne Research
url https://doi.org/10.1594/PANGAEA.973272