Raw mass spectrometric data to dissolved organic matter molecular composition data of exemplary water masses resolved by online LC-FT-ICR-MS

Fuente: PANGAEA
Guardado en:
Detalles Bibliográficos
Autores principales: Moye, Fabian, Bareth, Marlo, Koch, Boris P, Tebben, Jan, Harder, Tilmann
Formato: Dataset Open Access
Lenguaje:en
Publicado: PANGAEA 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1867169478735822848
author Moye, Fabian
Bareth, Marlo
Koch, Boris P
Tebben, Jan
Harder, Tilmann
author_facet Moye, Fabian
Bareth, Marlo
Koch, Boris P
Tebben, Jan
Harder, Tilmann
collection Datos científicos de ciencias marinas y ambientales
contents The unique chromatographic behaviour of DOM was investigated on three exemplary water samples representing coastal DOM, oceanic surface DOM and oceanic refractory DOM. Weddell Sea surface (30 m depth, oceanic surface DOM) and deep water (1356 m depth, refractory DOM) was sampled with a rosette sampler on RV Polarstern during ANT XXII/2 (station PS67/006-130, latitude -67.5633, longitude -55.3448) and are described elsewhere (El Naggar et al., 2007; Koch et al., 2008). Coastal DOM is routinely extracted from southern North Sea (latitude 54.1447, longitude 7.8711) and used as an in-house laboratory standard. Mass spectra were obtained with liquid chromatography coupled to a Fourier-transform ion cyclotron resonance mass spectrometer (LC-FT-ICR-MS) with negative electrospray ionisation. A 7 Tesla scimaX MRMS system (Bruker Daltonics GmbH & Co. KG, Bremen, Germany) was coupled to an ultra-performance liquid chromatography system (UPLC, Elute LC, Bruker Daltonics GmbH & Co. KG, Bremen, Germany). Reversed phase chromatography was done with a C18 column (Waters AQUITY 2 x 100 mm, 1.7 µm) column at 0.3 mL min 1 and a linear gradient: A (ultrapure water, 4 mmol L 1 ammonium formate) 2 min: 99 %, 11 min: 0 %, 14.9 min: 99 %; B (MeOH, 4 mmol L 1 ammonium formate) 2 min: 1 %, 11 min: 100 %, 14.5 min 100 %, 14.9 min 1 %. The exact mass lists and intensities of the 1.1 min binned scans were exported with the DataAnalysis 5.3 software package (Bruker Daltonics GmbH & Co. KG, Bremen, Germany).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_974711
institution PANGAEA
language en
publishDate 2025
publisher PANGAEA
record_format pangaea
spellingShingle Raw mass spectrometric data to dissolved organic matter molecular composition data of exemplary water masses resolved by online LC-FT-ICR-MS
Moye, Fabian
Bareth, Marlo
Koch, Boris P
Tebben, Jan
Harder, Tilmann
ANT-XXII/2; CTD/Rosette; CTD-RO; DEPTH, water; Dissolved Organic Matter; Event label; Fourier-transform ion cyclotron mass spectrometry; Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Intensity; Latitude of event; liquid chromatography high-resolution mass spectrometry; Longitude of event; Mass-to-charge ratio; molecular composition; Orbitrap; Peak resolution; Polarstern; PS67/006-130; PS67 ISPOL; Retention time; Sample ID; Signal/noise ratio; UT_NSSTD_01; UT20140917; Uthörn; Weddell Sea
The unique chromatographic behaviour of DOM was investigated on three exemplary water samples representing coastal DOM, oceanic surface DOM and oceanic refractory DOM. Weddell Sea surface (30 m depth, oceanic surface DOM) and deep water (1356 m depth, refractory DOM) was sampled with a rosette sampler on RV Polarstern during ANT XXII/2 (station PS67/006-130, latitude -67.5633, longitude -55.3448) and are described elsewhere (El Naggar et al., 2007; Koch et al., 2008). Coastal DOM is routinely extracted from southern North Sea (latitude 54.1447, longitude 7.8711) and used as an in-house laboratory standard. Mass spectra were obtained with liquid chromatography coupled to a Fourier-transform ion cyclotron resonance mass spectrometer (LC-FT-ICR-MS) with negative electrospray ionisation. A 7 Tesla scimaX MRMS system (Bruker Daltonics GmbH & Co. KG, Bremen, Germany) was coupled to an ultra-performance liquid chromatography system (UPLC, Elute LC, Bruker Daltonics GmbH & Co. KG, Bremen, Germany). Reversed phase chromatography was done with a C18 column (Waters AQUITY 2 x 100 mm, 1.7 µm) column at 0.3 mL min 1 and a linear gradient: A (ultrapure water, 4 mmol L 1 ammonium formate) 2 min: 99 %, 11 min: 0 %, 14.9 min: 99 %; B (MeOH, 4 mmol L 1 ammonium formate) 2 min: 1 %, 11 min: 100 %, 14.5 min 100 %, 14.9 min 1 %. The exact mass lists and intensities of the 1.1 min binned scans were exported with the DataAnalysis 5.3 software package (Bruker Daltonics GmbH & Co. KG, Bremen, Germany).
title Raw mass spectrometric data to dissolved organic matter molecular composition data of exemplary water masses resolved by online LC-FT-ICR-MS
topic ANT-XXII/2; CTD/Rosette; CTD-RO; DEPTH, water; Dissolved Organic Matter; Event label; Fourier-transform ion cyclotron mass spectrometry; Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Intensity; Latitude of event; liquid chromatography high-resolution mass spectrometry; Longitude of event; Mass-to-charge ratio; molecular composition; Orbitrap; Peak resolution; Polarstern; PS67/006-130; PS67 ISPOL; Retention time; Sample ID; Signal/noise ratio; UT_NSSTD_01; UT20140917; Uthörn; Weddell Sea
url https://doi.org/10.1594/PANGAEA.974711