Electromagnetic induction measurements with the vertically oriented dipole of the CMD Explorer (282 cm transmitter-receiver spacing) taken in the Ahr floodplain at Mayschoß, Rhineland-Palatinate (Germany)

Fuente: PANGAEA
Salvato in:
Dettagli Bibliografici
Autori principali: Pohle, Marco, Bauckholt, Matteo, Werban, Ulrike
Natura: Dataset Open Access
Lingua:en
Pubblicazione: PANGAEA 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867169479058784256
author Pohle, Marco
Bauckholt, Matteo
Werban, Ulrike
author_facet Pohle, Marco
Bauckholt, Matteo
Werban, Ulrike
collection Datos científicos de ciencias marinas y ambientales
contents Electromagnetic induction (EMI) was measured with a CMD-Mini Explorer and a CMD Explorer (both GF Instruments s.r.o., Brno, Czech Republic) in June 2022. We used the vertical dipole (VDP) at coil spacings of 0.32 m (VDP1, CMD Mini Explorer), 0.71 m (VDP2, CMD Mini Explorer), 1.18 m (VDP3, CMD Mini Explorer), 1.48 m (VDP4, CMD Explorer), 2.82 m (VDP5, CMD Explorer) and 4.49 m (VDP6, CMD Explorer). With the existing coil spacings, effective penetration depths of 0.5 m (VDP1), 1.0 m (VDP2) and 1.8 m (VDP3) for the CMD Mini Explorer and 2.2 m (VDP4), 4.2 m (VDP5) and 6.7 m (VDP6) for the CMD Explorer could be achieved. According to the manufacturer, 70 % of the signal originate from above these depths. The EMI sensors measured the apparent electrical conductivity (ECa, in mS/m). Measurements were taken by carrying the instrument about 0.2 m (CMD Mini Explorer) respectively 0.9 m (CMD Explorer) above the ground while being directly connected to Differential -GPS (Leica GPS1200) for positioning. The acquisition rate was five measurements per second. Data quality was checked by measuring a reference line before and after each measurement. The maximum offset of the EMI values between the two time points was 1.2 mS/m. A correction of the data was not necessary. We removed the reference lines and single outliers. In addition, two interference areas were removed from all EMI data sets. (1) a L-shapped area, running from north to the center and then to east, in which an underground power cable runs. (2) an area on the north-eastern part of the measurement area. Information on the location and extent of the removed interference areas can be found in the enclosed explanation of the EMI measurements. The data set contains the EMI data with an intercoil spacing of 2.82 m (VDP5, CMD Explorer).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_975008
institution PANGAEA
language en
publishDate 2025
publisher PANGAEA
record_format pangaea
spellingShingle Electromagnetic induction measurements with the vertically oriented dipole of the CMD Explorer (282 cm transmitter-receiver spacing) taken in the Ahr floodplain at Mayschoß, Rhineland-Palatinate (Germany)
Pohle, Marco
Bauckholt, Matteo
Werban, Ulrike
2022_Mayschoß_EMI; Ahr floodplain; Ahr river; Conductivity, electrical; DATE/TIME; Device type; Electromagnetic conductivity meter, GF Instruments, CMD Explorer [SN: 15030343]; electromagnetic induction; Electromagnetic induction; EMI; LATITUDE; Location; LONGITUDE; Orientation; Sample comment; Sample type; UTM Easting, Universal Transverse Mercator; UTM Northing, Universal Transverse Mercator; UTM Zone, Universal Transverse Mercator
Electromagnetic induction (EMI) was measured with a CMD-Mini Explorer and a CMD Explorer (both GF Instruments s.r.o., Brno, Czech Republic) in June 2022. We used the vertical dipole (VDP) at coil spacings of 0.32 m (VDP1, CMD Mini Explorer), 0.71 m (VDP2, CMD Mini Explorer), 1.18 m (VDP3, CMD Mini Explorer), 1.48 m (VDP4, CMD Explorer), 2.82 m (VDP5, CMD Explorer) and 4.49 m (VDP6, CMD Explorer). With the existing coil spacings, effective penetration depths of 0.5 m (VDP1), 1.0 m (VDP2) and 1.8 m (VDP3) for the CMD Mini Explorer and 2.2 m (VDP4), 4.2 m (VDP5) and 6.7 m (VDP6) for the CMD Explorer could be achieved. According to the manufacturer, 70 % of the signal originate from above these depths. The EMI sensors measured the apparent electrical conductivity (ECa, in mS/m). Measurements were taken by carrying the instrument about 0.2 m (CMD Mini Explorer) respectively 0.9 m (CMD Explorer) above the ground while being directly connected to Differential -GPS (Leica GPS1200) for positioning. The acquisition rate was five measurements per second. Data quality was checked by measuring a reference line before and after each measurement. The maximum offset of the EMI values between the two time points was 1.2 mS/m. A correction of the data was not necessary. We removed the reference lines and single outliers. In addition, two interference areas were removed from all EMI data sets. (1) a L-shapped area, running from north to the center and then to east, in which an underground power cable runs. (2) an area on the north-eastern part of the measurement area. Information on the location and extent of the removed interference areas can be found in the enclosed explanation of the EMI measurements. The data set contains the EMI data with an intercoil spacing of 2.82 m (VDP5, CMD Explorer).
title Electromagnetic induction measurements with the vertically oriented dipole of the CMD Explorer (282 cm transmitter-receiver spacing) taken in the Ahr floodplain at Mayschoß, Rhineland-Palatinate (Germany)
topic 2022_Mayschoß_EMI; Ahr floodplain; Ahr river; Conductivity, electrical; DATE/TIME; Device type; Electromagnetic conductivity meter, GF Instruments, CMD Explorer [SN: 15030343]; electromagnetic induction; Electromagnetic induction; EMI; LATITUDE; Location; LONGITUDE; Orientation; Sample comment; Sample type; UTM Easting, Universal Transverse Mercator; UTM Northing, Universal Transverse Mercator; UTM Zone, Universal Transverse Mercator
url https://doi.org/10.1594/PANGAEA.975008