CT raw data (DICOM format) of coral mound core GeoB16313-2 from the Campeche coral mound province, MARIA S. MERIAN cruise MSM20-4

Fuente: PANGAEA
Salvato in:
Dettagli Bibliografici
Autori principali: Titschack, Jürgen, Timann, Christian, Lemke, Arne-Jörn
Natura: Dataset Open Access
Lingua:en
Pubblicazione: PANGAEA 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867171898330185728
author Titschack, Jürgen
Timann, Christian
Lemke, Arne-Jörn
author_facet Titschack, Jürgen
Timann, Christian
Lemke, Arne-Jörn
collection Datos científicos de ciencias marinas y ambientales
contents Archive halves of gravity core GeoB16313-2 from a cold-water coral mound in the Campeche coral mound province, Gulf of Mexico, were scanned using a Toshiba Aquilion 64™ computer tomograph (CT) at the hospital Klinikum Bremen-Mitte, Germany, with an X-ray source voltage of 120 kV and a current of 600 mA. The CT image stacks have a resolution of 0.35 mm in the x and y directions and 0.5 mm resolution in the z direction (0.3 mm reconstruction interval). Images were reconstructed using Toshiba's patented helical cone beam reconstruction technique (TCOT).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_981823
institution PANGAEA
language en
publishDate 2025
publisher PANGAEA
record_format pangaea
spellingShingle CT raw data (DICOM format) of coral mound core GeoB16313-2 from the Campeche coral mound province, MARIA S. MERIAN cruise MSM20-4
Titschack, Jürgen
Timann, Christian
Lemke, Arne-Jörn
Binary Object; Binary Object (File Size); Binary Object (Media Type); Campeche Bank; Campeche coral mound province; cold-water coral mound; Computed Tomography; File content; GC; GeoB16313-2; Gravity corer; Gulf of Mexico; Maria S. Merian; MSM20/099-2; MSM20/4; WACOM
Archive halves of gravity core GeoB16313-2 from a cold-water coral mound in the Campeche coral mound province, Gulf of Mexico, were scanned using a Toshiba Aquilion 64™ computer tomograph (CT) at the hospital Klinikum Bremen-Mitte, Germany, with an X-ray source voltage of 120 kV and a current of 600 mA. The CT image stacks have a resolution of 0.35 mm in the x and y directions and 0.5 mm resolution in the z direction (0.3 mm reconstruction interval). Images were reconstructed using Toshiba's patented helical cone beam reconstruction technique (TCOT).
title CT raw data (DICOM format) of coral mound core GeoB16313-2 from the Campeche coral mound province, MARIA S. MERIAN cruise MSM20-4
topic Binary Object; Binary Object (File Size); Binary Object (Media Type); Campeche Bank; Campeche coral mound province; cold-water coral mound; Computed Tomography; File content; GC; GeoB16313-2; Gravity corer; Gulf of Mexico; Maria S. Merian; MSM20/099-2; MSM20/4; WACOM
url https://doi.org/10.1594/PANGAEA.981823