Sediment analyses (pH, electrical conductivity, mag. susceptibility, loss on ignition, remission) from the Araplı catchment in the Pergamon Micro-Region, western Turkey
Fuente:
PANGAEA
Gespeichert in:
| Hauptverfasser: | , , , , , |
|---|---|
| Format: | Dataset Open Access |
| Sprache: | en |
| Veröffentlicht: |
PANGAEA
2025
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1867168537266618368 |
|---|---|
| author | Starke, Joris Schütt, Brigitta Nykamp, Moritz Busch, Robert Doğan, M Becker, Fabian |
| author_facet | Starke, Joris Schütt, Brigitta Nykamp, Moritz Busch, Robert Doğan, M Becker, Fabian |
| collection | Datos científicos de ciencias marinas y ambientales |
| contents | The dataset was collected from seven sediment cores along a transect spanning the Araplı alluvial fan, east of ancient Pergamon, in the eastern lower Bakırçay plain, Pergamon micro-region, Türkiye. The cores were taken, described, sampled, and analyzed in the field and at the Bergama excavation house in October 2023. The soil description was conducted after Schoeneberger et al. (2002). Sediment samples were taken at irregular intervals and orientated along layer boundaries; samples include 3 cm of sediment in fine earth and 5 cm in gravelly material. Reported sample depths are simplified and given by their mean depth. Samples (n = 293) were analyzed for pH value, electrical conductivity, gravel content (sieve separate < 2 mm and > 2 mm), remission (sediment color using a spectrophotometer), loss on ignition (LOI, at 550 °C and 900 °C) after Dean (1974), and mass-specific magnetic susceptibility (calculated according to Dearing, 1994). |
| format | Dataset Open Access |
| id | pangaea_https___doi_org_10_1594_PANGAEA_983485 |
| institution | PANGAEA |
| language | en |
| publishDate | 2025 |
| publisher | PANGAEA |
| record_format | pangaea |
| spellingShingle | Sediment analyses (pH, electrical conductivity, mag. susceptibility, loss on ignition, remission) from the Araplı catchment in the Pergamon Micro-Region, western Turkey Starke, Joris Schütt, Brigitta Nykamp, Moritz Busch, Robert Doğan, M Becker, Fabian Alluvial fan; Ara-01; Ara-02; Ara-03; Ara-04; Ara-05; Ara-06; Ara-34; Bakırçay plain; Color, a; Color, b; Color, L; Conductivity, electrical; DEPTH, sediment/rock; Depth, sediment/rock, bottom/maximum; Depth, sediment/rock, top/minimum; Dry mass; Electrical conductivity; Event label; Fieldwork; Holocene; Identification; loss on ignition; Loss on ignition; Magnetic susceptibility; Magnetic susceptibility, mass; Magnetic susceptibility meter, Bartington, MS3; coupled with Dual Frequency Sensor, Bartington, MS2B; Mass; Muffel furnace, 550 °C, LOI; Muffel furnace, 900 °C, LOI; Multimeter, EZ9908 [resolution: 0.01 pH; 1 μS/cm EC]; PE23-PhyGeo-FUB; Pergamon micro-region; pH; Plate; pXRF; remission values; Sample mass; sediment profiles; Size fraction < 2.0 mm; Size fraction > 2 mm, gravel; Spectrophotometer, Konica Minolta, CM-2500d; VCW; Vibracoring, Wacker BHF 30 S, with open cores of 5 cm diameter; Wet mass The dataset was collected from seven sediment cores along a transect spanning the Araplı alluvial fan, east of ancient Pergamon, in the eastern lower Bakırçay plain, Pergamon micro-region, Türkiye. The cores were taken, described, sampled, and analyzed in the field and at the Bergama excavation house in October 2023. The soil description was conducted after Schoeneberger et al. (2002). Sediment samples were taken at irregular intervals and orientated along layer boundaries; samples include 3 cm of sediment in fine earth and 5 cm in gravelly material. Reported sample depths are simplified and given by their mean depth. Samples (n = 293) were analyzed for pH value, electrical conductivity, gravel content (sieve separate < 2 mm and > 2 mm), remission (sediment color using a spectrophotometer), loss on ignition (LOI, at 550 °C and 900 °C) after Dean (1974), and mass-specific magnetic susceptibility (calculated according to Dearing, 1994). |
| title | Sediment analyses (pH, electrical conductivity, mag. susceptibility, loss on ignition, remission) from the Araplı catchment in the Pergamon Micro-Region, western Turkey |
| topic | Alluvial fan; Ara-01; Ara-02; Ara-03; Ara-04; Ara-05; Ara-06; Ara-34; Bakırçay plain; Color, a; Color, b; Color, L; Conductivity, electrical; DEPTH, sediment/rock; Depth, sediment/rock, bottom/maximum; Depth, sediment/rock, top/minimum; Dry mass; Electrical conductivity; Event label; Fieldwork; Holocene; Identification; loss on ignition; Loss on ignition; Magnetic susceptibility; Magnetic susceptibility, mass; Magnetic susceptibility meter, Bartington, MS3; coupled with Dual Frequency Sensor, Bartington, MS2B; Mass; Muffel furnace, 550 °C, LOI; Muffel furnace, 900 °C, LOI; Multimeter, EZ9908 [resolution: 0.01 pH; 1 μS/cm EC]; PE23-PhyGeo-FUB; Pergamon micro-region; pH; Plate; pXRF; remission values; Sample mass; sediment profiles; Size fraction < 2.0 mm; Size fraction > 2 mm, gravel; Spectrophotometer, Konica Minolta, CM-2500d; VCW; Vibracoring, Wacker BHF 30 S, with open cores of 5 cm diameter; Wet mass |
| url | https://doi.org/10.1594/PANGAEA.983485 |