Iberia-Forams cruise in September 2012 - discrete sample pH data

Fuente: PANGAEA
Saved in:
Bibliographic Details
Main Author: Voelker, Antje H L
Format: Dataset Open Access
Language:en
Published: PANGAEA 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867169172626079744
author Voelker, Antje H L
author_facet Voelker, Antje H L
collection Datos científicos de ciencias marinas y ambientales
contents This data set provides the pH values obtained for discrete water samples collected from the CTD+Rosette assembly at the water levels sampled during the Iberia-Forams cruise along the western and southwestern Iberian margin in September 2012. For pH measurement 250 ml of water were collected from the Rosette bottle and the bottle closed tightly. In the lab, the respective pH value was obtained by inserting a WTW (Wissenschaftlich-Technische Werkstaetten GmbH) pH meter 3110 into the bottom half of each bottle. Before the measurement, the pH probe was calibrated with pH solutions of 4.01 and 7.00 (accuracy of ≤ 0.005 pH ± 1 digit). Listed pH values are generally the mean of two measurements.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_988161
institution PANGAEA
language en
publishDate 2025
publisher PANGAEA
record_format pangaea
spellingShingle Iberia-Forams cruise in September 2012 - discrete sample pH data
Voelker, Antje H L
CTD/Rosette; CTD data; CTD-RO; Date/Time of event; DEPTH, water; Elevation of event; EUROFLEETS_Iberia-Forams; Event label; Garcia del Cid; Iberian margin; Ib-F1; Ib-F10; Ib-F11; Ib-F12; Ib-F2; Ib-F3; Ib-F4; Ib-F5; Ib-F6; Ib-F7; Ib-F8; Ib-F9; Latitude of event; Longitude of event; North Atlantic Ocean; pH
This data set provides the pH values obtained for discrete water samples collected from the CTD+Rosette assembly at the water levels sampled during the Iberia-Forams cruise along the western and southwestern Iberian margin in September 2012. For pH measurement 250 ml of water were collected from the Rosette bottle and the bottle closed tightly. In the lab, the respective pH value was obtained by inserting a WTW (Wissenschaftlich-Technische Werkstaetten GmbH) pH meter 3110 into the bottom half of each bottle. Before the measurement, the pH probe was calibrated with pH solutions of 4.01 and 7.00 (accuracy of ≤ 0.005 pH ± 1 digit). Listed pH values are generally the mean of two measurements.
title Iberia-Forams cruise in September 2012 - discrete sample pH data
topic CTD/Rosette; CTD data; CTD-RO; Date/Time of event; DEPTH, water; Elevation of event; EUROFLEETS_Iberia-Forams; Event label; Garcia del Cid; Iberian margin; Ib-F1; Ib-F10; Ib-F11; Ib-F12; Ib-F2; Ib-F3; Ib-F4; Ib-F5; Ib-F6; Ib-F7; Ib-F8; Ib-F9; Latitude of event; Longitude of event; North Atlantic Ocean; pH
url https://doi.org/10.1594/PANGAEA.988161