_version_ 1867169491134185472
author Zhang, Yang
Frederichs, Thomas
author_facet Zhang, Yang
Frederichs, Thomas
collection Datos científicos de ciencias marinas y ambientales
contents Low-temperature magnetic cycling provides complementary information on mineral magnetic properties. We used the Quantum Design MPMS-XL7 Magnetic Property Measurement System at the Bremen Lab to measure warming curves of zero-field cooled (ZFC) and field-cooled (FC) saturation IRM (SIRM) acquired, respectively, during cooling to 5 K in a zero field and 2.5 T field. Changes of room temperature SIRM (RT-SIRM) were measured while cycling samples in zero field down to 5 K and back to room temperature.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_991430
institution PANGAEA
language en
publishDate 2026
publisher PANGAEA
record_format pangaea
spellingShingle Low-temperature thermomagnetic measurements of 11 sediment samples from IODP Site 378-U1553, southern Campbell Plateau
Zhang, Yang
Frederichs, Thomas
378-U1553A; 378-U1553B; 378-U1553E; Depth, composite revised; Depth correlation/correction; Diagenesis; DRILL; Drilling/drill rig; DSDP/ODP/IODP sample designation; Event label; Exp378; Field cooling, MPMS, Quantum Design; International Ocean Drilling Programme; IODP3; IODP 378; Joides Resolution; Magnetization, normalized; Magnetostratigraphy; Quantum Design XL7 Magnetic Properties Measurement System (MPMS); rock magnetism; Room-temperature SIRM low-T cycling, Quantum Design; Sample code/label; South Pacific; South Pacific Ocean; Temperature, device; Zero-field cooling, MPMS, Quantum Design
Low-temperature magnetic cycling provides complementary information on mineral magnetic properties. We used the Quantum Design MPMS-XL7 Magnetic Property Measurement System at the Bremen Lab to measure warming curves of zero-field cooled (ZFC) and field-cooled (FC) saturation IRM (SIRM) acquired, respectively, during cooling to 5 K in a zero field and 2.5 T field. Changes of room temperature SIRM (RT-SIRM) were measured while cycling samples in zero field down to 5 K and back to room temperature.
title Low-temperature thermomagnetic measurements of 11 sediment samples from IODP Site 378-U1553, southern Campbell Plateau
topic 378-U1553A; 378-U1553B; 378-U1553E; Depth, composite revised; Depth correlation/correction; Diagenesis; DRILL; Drilling/drill rig; DSDP/ODP/IODP sample designation; Event label; Exp378; Field cooling, MPMS, Quantum Design; International Ocean Drilling Programme; IODP3; IODP 378; Joides Resolution; Magnetization, normalized; Magnetostratigraphy; Quantum Design XL7 Magnetic Properties Measurement System (MPMS); rock magnetism; Room-temperature SIRM low-T cycling, Quantum Design; Sample code/label; South Pacific; South Pacific Ocean; Temperature, device; Zero-field cooling, MPMS, Quantum Design
url https://doi.org/10.1594/PANGAEA.991430