Saved in:
| Main Authors: | , |
|---|---|
| Format: | Dataset Open Access |
| Language: | en |
| Published: |
PANGAEA
2026
|
| Subjects: | |
| Online Access: | https://doi.org/10.1594/PANGAEA.991430 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1867169491134185472 |
|---|---|
| author | Zhang, Yang Frederichs, Thomas |
| author_facet | Zhang, Yang Frederichs, Thomas |
| collection | Datos científicos de ciencias marinas y ambientales |
| contents | Low-temperature magnetic cycling provides complementary information on mineral magnetic properties. We used the Quantum Design MPMS-XL7 Magnetic Property Measurement System at the Bremen Lab to measure warming curves of zero-field cooled (ZFC) and field-cooled (FC) saturation IRM (SIRM) acquired, respectively, during cooling to 5 K in a zero field and 2.5 T field. Changes of room temperature SIRM (RT-SIRM) were measured while cycling samples in zero field down to 5 K and back to room temperature. |
| format | Dataset Open Access |
| id | pangaea_https___doi_org_10_1594_PANGAEA_991430 |
| institution | PANGAEA |
| language | en |
| publishDate | 2026 |
| publisher | PANGAEA |
| record_format | pangaea |
| spellingShingle | Low-temperature thermomagnetic measurements of 11 sediment samples from IODP Site 378-U1553, southern Campbell Plateau Zhang, Yang Frederichs, Thomas 378-U1553A; 378-U1553B; 378-U1553E; Depth, composite revised; Depth correlation/correction; Diagenesis; DRILL; Drilling/drill rig; DSDP/ODP/IODP sample designation; Event label; Exp378; Field cooling, MPMS, Quantum Design; International Ocean Drilling Programme; IODP3; IODP 378; Joides Resolution; Magnetization, normalized; Magnetostratigraphy; Quantum Design XL7 Magnetic Properties Measurement System (MPMS); rock magnetism; Room-temperature SIRM low-T cycling, Quantum Design; Sample code/label; South Pacific; South Pacific Ocean; Temperature, device; Zero-field cooling, MPMS, Quantum Design Low-temperature magnetic cycling provides complementary information on mineral magnetic properties. We used the Quantum Design MPMS-XL7 Magnetic Property Measurement System at the Bremen Lab to measure warming curves of zero-field cooled (ZFC) and field-cooled (FC) saturation IRM (SIRM) acquired, respectively, during cooling to 5 K in a zero field and 2.5 T field. Changes of room temperature SIRM (RT-SIRM) were measured while cycling samples in zero field down to 5 K and back to room temperature. |
| title | Low-temperature thermomagnetic measurements of 11 sediment samples from IODP Site 378-U1553, southern Campbell Plateau |
| topic | 378-U1553A; 378-U1553B; 378-U1553E; Depth, composite revised; Depth correlation/correction; Diagenesis; DRILL; Drilling/drill rig; DSDP/ODP/IODP sample designation; Event label; Exp378; Field cooling, MPMS, Quantum Design; International Ocean Drilling Programme; IODP3; IODP 378; Joides Resolution; Magnetization, normalized; Magnetostratigraphy; Quantum Design XL7 Magnetic Properties Measurement System (MPMS); rock magnetism; Room-temperature SIRM low-T cycling, Quantum Design; Sample code/label; South Pacific; South Pacific Ocean; Temperature, device; Zero-field cooling, MPMS, Quantum Design |
| url | https://doi.org/10.1594/PANGAEA.991430 |