Salvato in:
Dettagli Bibliografici
Autori principali: do Nascimento, Mariah C A, Smith, Wendy J M, Liu, Yawen, da Costa, Vivaldo Gomes, Simpson, Stuart L, Bivins, Aaron, Rahal, Paula, Ahmed, Warish
Natura: Artículo científico
Lingua:en
Pubblicazione: Journal of water and health 2025
Soggetti:
Accesso online:https://pubmed.ncbi.nlm.nih.gov/40586335/
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1868266184100544512
author do Nascimento, Mariah C A
Smith, Wendy J M
Liu, Yawen
da Costa, Vivaldo Gomes
Simpson, Stuart L
Bivins, Aaron
Rahal, Paula
Ahmed, Warish
author_facet do Nascimento, Mariah C A
Smith, Wendy J M
Liu, Yawen
da Costa, Vivaldo Gomes
Simpson, Stuart L
Bivins, Aaron
Rahal, Paula
Ahmed, Warish
do Nascimento, Mariah C A
Smith, Wendy J M
Liu, Yawen
da Costa, Vivaldo Gomes
Simpson, Stuart L
Bivins, Aaron
Rahal, Paula
Ahmed, Warish
collection PubMed - marine biology
contents Comparative evaluation of heating instruments for detecting HF183, SARS-CoV-2, and Aichi virus A in untreated wastewater using colorimetric LAMP. do Nascimento, Mariah C A Smith, Wendy J M Liu, Yawen da Costa, Vivaldo Gomes Simpson, Stuart L Bivins, Aaron Rahal, Paula Ahmed, Warish Wastewater SARS-CoV-2 Nucleic Acid Amplification Techniques Colorimetry Bacteroides Kobuvirus Molecular Diagnostic Techniques This study assessed the accuracy, field suitability, and cost-effectiveness of colorimetric LAMP (c-LAMP) assays using six heating instruments: Electric Kettle, Water Bath, Heating Block, miniPCR, Thermocycler, and Genie® III. Bacteroides HF183 (HF183), SARS-CoV-2, and Aichi virus A (AiV-A) were tested using control materials and wastewater samples, comparing cLAMP with qPCR/RT-qPCR detection. qPCR/RT-qPCR reliably detected HF183 and AiV-A genetic fragments at dilutions as low as 1 × 10 pg/μL, corresponding to 1.24 and 1.49 log GC/reaction. cLAMP/RT-cLAMP detected these fragments at 1 × 10 pg/μL (2.28 and 2.63 log GC/reaction), though Electric Kettle, miniPCR, and Genie® III occasionally produced false negatives. RT-qPCR reliably detected SARS-CoV-2 fragments at 1 × 10 GC/μL (1.86 log GC/reaction), with cLAMP/RT-cLAMP performing similarly across most instruments except Thermocycler. No significant differences (p > 0.05) were observed among instruments, though inconsistencies appeared at lower concentrations. The findings offer valuable insights into heating instrument performance for cLAMP/RT-cLAMP assays, guiding their application in wastewater-based pathogen detection.
format Artículo científico
id pubmed_40586335
institution PubMed
language en
publishDate 2025
publisher Journal of water and health
record_format pubmed
spellingShingle Comparative evaluation of heating instruments for detecting HF183, SARS-CoV-2, and Aichi virus A in untreated wastewater using colorimetric LAMP.
do Nascimento, Mariah C A
Smith, Wendy J M
Liu, Yawen
da Costa, Vivaldo Gomes
Simpson, Stuart L
Bivins, Aaron
Rahal, Paula
Ahmed, Warish
Wastewater
SARS-CoV-2
Nucleic Acid Amplification Techniques
Colorimetry
Bacteroides
Kobuvirus
Molecular Diagnostic Techniques
Comparative evaluation of heating instruments for detecting HF183, SARS-CoV-2, and Aichi virus A in untreated wastewater using colorimetric LAMP. do Nascimento, Mariah C A Smith, Wendy J M Liu, Yawen da Costa, Vivaldo Gomes Simpson, Stuart L Bivins, Aaron Rahal, Paula Ahmed, Warish Wastewater SARS-CoV-2 Nucleic Acid Amplification Techniques Colorimetry Bacteroides Kobuvirus Molecular Diagnostic Techniques This study assessed the accuracy, field suitability, and cost-effectiveness of colorimetric LAMP (c-LAMP) assays using six heating instruments: Electric Kettle, Water Bath, Heating Block, miniPCR, Thermocycler, and Genie® III. Bacteroides HF183 (HF183), SARS-CoV-2, and Aichi virus A (AiV-A) were tested using control materials and wastewater samples, comparing cLAMP with qPCR/RT-qPCR detection. qPCR/RT-qPCR reliably detected HF183 and AiV-A genetic fragments at dilutions as low as 1 × 10 pg/μL, corresponding to 1.24 and 1.49 log GC/reaction. cLAMP/RT-cLAMP detected these fragments at 1 × 10 pg/μL (2.28 and 2.63 log GC/reaction), though Electric Kettle, miniPCR, and Genie® III occasionally produced false negatives. RT-qPCR reliably detected SARS-CoV-2 fragments at 1 × 10 GC/μL (1.86 log GC/reaction), with cLAMP/RT-cLAMP performing similarly across most instruments except Thermocycler. No significant differences (p > 0.05) were observed among instruments, though inconsistencies appeared at lower concentrations. The findings offer valuable insights into heating instrument performance for cLAMP/RT-cLAMP assays, guiding their application in wastewater-based pathogen detection.
title Comparative evaluation of heating instruments for detecting HF183, SARS-CoV-2, and Aichi virus A in untreated wastewater using colorimetric LAMP.
topic Wastewater
SARS-CoV-2
Nucleic Acid Amplification Techniques
Colorimetry
Bacteroides
Kobuvirus
Molecular Diagnostic Techniques
url https://pubmed.ncbi.nlm.nih.gov/40586335/