Polymeric Membrane Potentiometric Ion Sensors with Dual Biocompatible Functionality.

Fuente: PubMed
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Liu, Zhe, Wang, Peng, Zhao, Haijie, Liu, Aohua, Liang, Rongning, Qin, Wei
Format: Artículo científico
Sprache:en
Veröffentlicht: Analytical chemistry 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1868266130269798401
author Liu, Zhe
Wang, Peng
Zhao, Haijie
Liu, Aohua
Liang, Rongning
Qin, Wei
author_facet Liu, Zhe
Wang, Peng
Zhao, Haijie
Liu, Aohua
Liang, Rongning
Qin, Wei
Liu, Zhe
Wang, Peng
Zhao, Haijie
Liu, Aohua
Liang, Rongning
Qin, Wei
collection PubMed - marine biology
contents Polymeric Membrane Potentiometric Ion Sensors with Dual Biocompatible Functionality. Liu, Zhe Wang, Peng Zhao, Haijie Liu, Aohua Liang, Rongning Qin, Wei Potentiometry Humans Biocompatible Materials Calcium Ion-Selective Electrodes Membranes, Artificial Polymers Cell Adhesion Methacrylates Polymeric membrane ion-selective electrodes (ISEs) have been routinely used to detect clinically important ions in physiological samples. However, the development of biocompatible potentiometric ion sensors for long-term measurements remains a significant challenge. Herein, a polymeric membrane Ca-ISE with dual biocompatible functionality (i.e., antibiofouling and low-cytotoxicity properties) is proposed. It is based on a semifluorinated, plasticizer-free sensing membrane with an immobilized ionophore. A new semifluorinated copolymer, 1H,1H,2H,2H-perfluorooctyl methacrylate-lauryl methacrylate (PFMA-LMA), has been synthesized. The low surface energy of the semifluorinated membrane could effectively prevent the surface adsorption of foulants such as lipids, proteins, and blood cells from biological samples. The immobilization of the sensing component and the plasticizer-free approach could significantly reduce the physiological toxicity of the sensor. Compared to the conventional plasticized poly(vinyl chloride) (PVC)-based membrane Ca-ISE, the bifunctional, biocompatible PFMA-LMA membrane electrode exhibits significantly reduced blood cell adhesion and cytotoxicity. The present sensor could be used for continuous real-time monitoring of Ca in human blood for at least 3 days. The proposed strategy of dual biocompatible functionality has promising potential for the development of implantable and wearable polymeric membrane-based electrochemical and optical sensors.
format Artículo científico
id pubmed_41216712
institution PubMed
language en
publishDate 2025
publisher Analytical chemistry
record_format pubmed
spellingShingle Polymeric Membrane Potentiometric Ion Sensors with Dual Biocompatible Functionality.
Liu, Zhe
Wang, Peng
Zhao, Haijie
Liu, Aohua
Liang, Rongning
Qin, Wei
Potentiometry
Humans
Biocompatible Materials
Calcium
Ion-Selective Electrodes
Membranes, Artificial
Polymers
Cell Adhesion
Methacrylates
Polymeric Membrane Potentiometric Ion Sensors with Dual Biocompatible Functionality. Liu, Zhe Wang, Peng Zhao, Haijie Liu, Aohua Liang, Rongning Qin, Wei Potentiometry Humans Biocompatible Materials Calcium Ion-Selective Electrodes Membranes, Artificial Polymers Cell Adhesion Methacrylates Polymeric membrane ion-selective electrodes (ISEs) have been routinely used to detect clinically important ions in physiological samples. However, the development of biocompatible potentiometric ion sensors for long-term measurements remains a significant challenge. Herein, a polymeric membrane Ca-ISE with dual biocompatible functionality (i.e., antibiofouling and low-cytotoxicity properties) is proposed. It is based on a semifluorinated, plasticizer-free sensing membrane with an immobilized ionophore. A new semifluorinated copolymer, 1H,1H,2H,2H-perfluorooctyl methacrylate-lauryl methacrylate (PFMA-LMA), has been synthesized. The low surface energy of the semifluorinated membrane could effectively prevent the surface adsorption of foulants such as lipids, proteins, and blood cells from biological samples. The immobilization of the sensing component and the plasticizer-free approach could significantly reduce the physiological toxicity of the sensor. Compared to the conventional plasticized poly(vinyl chloride) (PVC)-based membrane Ca-ISE, the bifunctional, biocompatible PFMA-LMA membrane electrode exhibits significantly reduced blood cell adhesion and cytotoxicity. The present sensor could be used for continuous real-time monitoring of Ca in human blood for at least 3 days. The proposed strategy of dual biocompatible functionality has promising potential for the development of implantable and wearable polymeric membrane-based electrochemical and optical sensors.
title Polymeric Membrane Potentiometric Ion Sensors with Dual Biocompatible Functionality.
topic Potentiometry
Humans
Biocompatible Materials
Calcium
Ion-Selective Electrodes
Membranes, Artificial
Polymers
Cell Adhesion
Methacrylates
url https://pubmed.ncbi.nlm.nih.gov/41216712/