Saved in:
Bibliographic Details
Main Authors: Rokitta, Sebastian D, Chamberlain, Emelia J, D Angelo, Alessandra, Bowman, Jeff S, Loose, Brice, Ulfsbo, Adam, Fong, Allison A, Richter, Klaus-Uwe, Kranz, Sven A, Rost, Björn
Format: Artículo científico
Language:en
Published: Analytical chemistry 2025
Subjects:
Online Access:https://pubmed.ncbi.nlm.nih.gov/41290359/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1868266122539696129
author Rokitta, Sebastian D
Chamberlain, Emelia J
D Angelo, Alessandra
Bowman, Jeff S
Loose, Brice
Ulfsbo, Adam
Fong, Allison A
Richter, Klaus-Uwe
Kranz, Sven A
Rost, Björn
author_facet Rokitta, Sebastian D
Chamberlain, Emelia J
D Angelo, Alessandra
Bowman, Jeff S
Loose, Brice
Ulfsbo, Adam
Fong, Allison A
Richter, Klaus-Uwe
Kranz, Sven A
Rost, Björn
Rokitta, Sebastian D
Chamberlain, Emelia J
D Angelo, Alessandra
Bowman, Jeff S
Loose, Brice
Ulfsbo, Adam
Fong, Allison A
Richter, Klaus-Uwe
Kranz, Sven A
Rost, Björn
collection PubMed - marine biology
contents Baselines Matter: Mass Spectrometric Assessments of Biological O Supersaturation (ΔO:Ar) Benefit from Two-Point Calibrations. Rokitta, Sebastian D Chamberlain, Emelia J D Angelo, Alessandra Bowman, Jeff S Loose, Brice Ulfsbo, Adam Fong, Allison A Richter, Klaus-Uwe Kranz, Sven A Rost, Björn Calibration Mass Spectrometry Oxygen Membrane-inlet mass spectrometry (MIMS) based assessments of ΔO:Ar to estimate marine productivity are becoming a widely used tool in biogeochemistry. Especially continuous ship-borne surveys of dissolved gases allow for high spatial and temporal resolution in the analysis of surface ocean net community productivity. Depending on instrument configuration and architecture, however, measurements may be afflicted with substantial detection baselines for each analyzed gas. We hypothesized that ignoring these baselines (as seems to be common practice) can considerably affect the outcomes of the measurements. Using MIMS data from two cruises, we assessed the impact of calibration procedures and different pressure regimes, i.e., gas loads, on the ΔO:Ar ratios and analyses of net community productivity. We compared conventional ratio-based one-point calibration approaches with two-point calibration approaches that include baselines and either calibrate for the equilibrium ratio of O:Ar, or calibrate for the individual gas concentrations. Our data show that higher gas loads increase apparent signal heights, but also disproportionately increase the individual gas-associated baseline levels, thereby reducing instrument sensitivity while increasing a potential bias if data is used without correction. Depending on the adjusted gas loads, severe underestimations of final ΔO:Ar values by factors of ca. 1.4 and 4 were calculated when disregarding baselines, emphasizing the critical importance of baseline determinations in MIMS-based methods.
format Artículo científico
id pubmed_41290359
institution PubMed
language en
publishDate 2025
publisher Analytical chemistry
record_format pubmed
spellingShingle Baselines Matter: Mass Spectrometric Assessments of Biological O Supersaturation (ΔO:Ar) Benefit from Two-Point Calibrations.
Rokitta, Sebastian D
Chamberlain, Emelia J
D Angelo, Alessandra
Bowman, Jeff S
Loose, Brice
Ulfsbo, Adam
Fong, Allison A
Richter, Klaus-Uwe
Kranz, Sven A
Rost, Björn
Calibration
Mass Spectrometry
Oxygen
Baselines Matter: Mass Spectrometric Assessments of Biological O Supersaturation (ΔO:Ar) Benefit from Two-Point Calibrations. Rokitta, Sebastian D Chamberlain, Emelia J D Angelo, Alessandra Bowman, Jeff S Loose, Brice Ulfsbo, Adam Fong, Allison A Richter, Klaus-Uwe Kranz, Sven A Rost, Björn Calibration Mass Spectrometry Oxygen Membrane-inlet mass spectrometry (MIMS) based assessments of ΔO:Ar to estimate marine productivity are becoming a widely used tool in biogeochemistry. Especially continuous ship-borne surveys of dissolved gases allow for high spatial and temporal resolution in the analysis of surface ocean net community productivity. Depending on instrument configuration and architecture, however, measurements may be afflicted with substantial detection baselines for each analyzed gas. We hypothesized that ignoring these baselines (as seems to be common practice) can considerably affect the outcomes of the measurements. Using MIMS data from two cruises, we assessed the impact of calibration procedures and different pressure regimes, i.e., gas loads, on the ΔO:Ar ratios and analyses of net community productivity. We compared conventional ratio-based one-point calibration approaches with two-point calibration approaches that include baselines and either calibrate for the equilibrium ratio of O:Ar, or calibrate for the individual gas concentrations. Our data show that higher gas loads increase apparent signal heights, but also disproportionately increase the individual gas-associated baseline levels, thereby reducing instrument sensitivity while increasing a potential bias if data is used without correction. Depending on the adjusted gas loads, severe underestimations of final ΔO:Ar values by factors of ca. 1.4 and 4 were calculated when disregarding baselines, emphasizing the critical importance of baseline determinations in MIMS-based methods.
title Baselines Matter: Mass Spectrometric Assessments of Biological O Supersaturation (ΔO:Ar) Benefit from Two-Point Calibrations.
topic Calibration
Mass Spectrometry
Oxygen
url https://pubmed.ncbi.nlm.nih.gov/41290359/