Salvato in:
Dettagli Bibliografici
Autori principali: Liu, Lu, Liu, Shusheng, Liang, Rongning, Qin, Wei
Natura: Artículo científico
Lingua:en
Pubblicazione: The Analyst 2026
Soggetti:
Accesso online:https://pubmed.ncbi.nlm.nih.gov/41736483/
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1868266082207268864
author Liu, Lu
Liu, Shusheng
Liang, Rongning
Qin, Wei
author_facet Liu, Lu
Liu, Shusheng
Liang, Rongning
Qin, Wei
Liu, Lu
Liu, Shusheng
Liang, Rongning
Qin, Wei
collection PubMed - marine biology
contents Versatile polymeric membrane ion-selective electrodes based on cellulose triacetate. Liu, Lu Liu, Shusheng Liang, Rongning Qin, Wei Cellulose Ion-Selective Electrodes Membranes, Artificial Potentiometry Biosensing Techniques Polyvinyl Chloride Calcium Polymers Enzymes, Immobilized Nowadays, polymeric membrane ion-selective electrodes (ISEs) based on poly(vinyl chloride) (PVC) matrices are widely used in clinical diagnosis and environmental monitoring. However, the chemical inertness of PVC may limit sensor applications in some scenarios, such as surface modification and construction of potentiometric biosensors through surface grafting of receptors. In this work, cellulose triacetate (CTA) is employed as a membrane matrix to prepare polymeric membrane ISEs. The versatile properties of the proposed CTA-based potentiometric sensors in terms of biocompatibility, biodegradability and easy chemical modification are illustrated. As a proof-of-concept experiment, polymeric membrane Ca-ISEs using CTA as the membrane matrix have been fabricated. The electrode has a linear range of 1.0 × 10 to 1.0 × 10 M with a Nernstian slope of 29.19 ± 0.97 mV dec. A surface hydrophilic CTA-based Ca-ISE membrane can be simply obtained by alkaline hydrolysis of the electrode. The hydrolyzed surface of the obtained membrane can further be activated with carbonyldiimidazole (CDI) for the direct immobilization of the functionalized agent, polysaccharide chitosan, on the surface of the membranes. In addition, an enzyme, butyrylcholinesterase, can also be immobilized onto the ISE surface through a similar CDI reaction, which provides great potential for fabrication of new potentiometric biosensors. It will be shown that CTA can be used as a powerful membrane matrix alternative to the classical PVC matrix for fabrication of polymeric membrane optical and electrochemical sensors in clinical applications.
format Artículo científico
id pubmed_41736483
institution PubMed
language en
publishDate 2026
publisher The Analyst
record_format pubmed
spellingShingle Versatile polymeric membrane ion-selective electrodes based on cellulose triacetate.
Liu, Lu
Liu, Shusheng
Liang, Rongning
Qin, Wei
Cellulose
Ion-Selective Electrodes
Membranes, Artificial
Potentiometry
Biosensing Techniques
Polyvinyl Chloride
Calcium
Polymers
Enzymes, Immobilized
Versatile polymeric membrane ion-selective electrodes based on cellulose triacetate. Liu, Lu Liu, Shusheng Liang, Rongning Qin, Wei Cellulose Ion-Selective Electrodes Membranes, Artificial Potentiometry Biosensing Techniques Polyvinyl Chloride Calcium Polymers Enzymes, Immobilized Nowadays, polymeric membrane ion-selective electrodes (ISEs) based on poly(vinyl chloride) (PVC) matrices are widely used in clinical diagnosis and environmental monitoring. However, the chemical inertness of PVC may limit sensor applications in some scenarios, such as surface modification and construction of potentiometric biosensors through surface grafting of receptors. In this work, cellulose triacetate (CTA) is employed as a membrane matrix to prepare polymeric membrane ISEs. The versatile properties of the proposed CTA-based potentiometric sensors in terms of biocompatibility, biodegradability and easy chemical modification are illustrated. As a proof-of-concept experiment, polymeric membrane Ca-ISEs using CTA as the membrane matrix have been fabricated. The electrode has a linear range of 1.0 × 10 to 1.0 × 10 M with a Nernstian slope of 29.19 ± 0.97 mV dec. A surface hydrophilic CTA-based Ca-ISE membrane can be simply obtained by alkaline hydrolysis of the electrode. The hydrolyzed surface of the obtained membrane can further be activated with carbonyldiimidazole (CDI) for the direct immobilization of the functionalized agent, polysaccharide chitosan, on the surface of the membranes. In addition, an enzyme, butyrylcholinesterase, can also be immobilized onto the ISE surface through a similar CDI reaction, which provides great potential for fabrication of new potentiometric biosensors. It will be shown that CTA can be used as a powerful membrane matrix alternative to the classical PVC matrix for fabrication of polymeric membrane optical and electrochemical sensors in clinical applications.
title Versatile polymeric membrane ion-selective electrodes based on cellulose triacetate.
topic Cellulose
Ion-Selective Electrodes
Membranes, Artificial
Potentiometry
Biosensing Techniques
Polyvinyl Chloride
Calcium
Polymers
Enzymes, Immobilized
url https://pubmed.ncbi.nlm.nih.gov/41736483/