Visualizing nanoplastic-metal ion co-exposure stress with an NIR biothiol responsive fluorescent probe.

Fuente: PubMed
Salvato in:
Dettagli Bibliografici
Autori principali: Wei, Shaoyu, Zhang, Liangwei, Tan, Jiangkun, Liu, Shudi, Arabi, Maryam, Ostovan, Abbas, Zhuang, Xuming, Chen, Lingxin
Natura: Artículo científico
Lingua:en
Pubblicazione: The Analyst 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1868266051133767680
author Wei, Shaoyu
Zhang, Liangwei
Tan, Jiangkun
Liu, Shudi
Arabi, Maryam
Ostovan, Abbas
Zhuang, Xuming
Chen, Lingxin
author_facet Wei, Shaoyu
Zhang, Liangwei
Tan, Jiangkun
Liu, Shudi
Arabi, Maryam
Ostovan, Abbas
Zhuang, Xuming
Chen, Lingxin
Wei, Shaoyu
Zhang, Liangwei
Tan, Jiangkun
Liu, Shudi
Arabi, Maryam
Ostovan, Abbas
Zhuang, Xuming
Chen, Lingxin
collection PubMed - marine biology
contents Visualizing nanoplastic-metal ion co-exposure stress with an NIR biothiol responsive fluorescent probe. Wei, Shaoyu Zhang, Liangwei Tan, Jiangkun Liu, Shudi Arabi, Maryam Ostovan, Abbas Zhuang, Xuming Chen, Lingxin Zebrafish Animals Fluorescent Dyes Fluorescent Chemosensor Compounds Humans Sulfhydryl Compounds Oxidative Stress Mercury Glutathione Polymethyl Methacrylate Naphthalimides HeLa Cells Limit of Detection Cysteine Infrared Rays Visualizing the combined toxic effects of micro(nano)plastics and heavy metal ions remains challenging due to the lack of suitable imaging tools, and current co-exposure models are often simplified by simple mixing rather than using pre-formed complexes. In this work, a near-infrared biothiol fluorescent probe was developed based on a naphthalimide scaffold with an α,β-unsaturated acetyl group as a recognition site. The probe exhibits high sensitivity and selectivity toward biothiols, and the detection limit was determined to be 0.47 μM for Cys, 0.37 μM for GSH, and 0.95 μM for Hcy, respectively. This enables the monitoring of biothiol fluctuations in living cells and zebrafish. Using pre-formed PMMA-Hg complexes as co-exposure pollutant models, we investigated nanoplastic-metal ion complex induced oxidative stress in living cells and zebrafish. Imaging results revealed that PMMA-Hg complex co-exposure induces distinct biothiol fluctuation patterns compared to single exposure of PMMA or Hg. The surface charge alterations of complexes and lysosomal function were found to be involved in the process. This study provides visual evidence for elucidating the combined toxicity mechanisms of nanoplastic-heavy metal complex co-exposure.
format Artículo científico
id pubmed_42084039
institution PubMed
language en
publishDate 2026
publisher The Analyst
record_format pubmed
spellingShingle Visualizing nanoplastic-metal ion co-exposure stress with an NIR biothiol responsive fluorescent probe.
Wei, Shaoyu
Zhang, Liangwei
Tan, Jiangkun
Liu, Shudi
Arabi, Maryam
Ostovan, Abbas
Zhuang, Xuming
Chen, Lingxin
Zebrafish
Animals
Fluorescent Dyes
Fluorescent Chemosensor Compounds
Humans
Sulfhydryl Compounds
Oxidative Stress
Mercury
Glutathione
Polymethyl Methacrylate
Naphthalimides
HeLa Cells
Limit of Detection
Cysteine
Infrared Rays
Visualizing nanoplastic-metal ion co-exposure stress with an NIR biothiol responsive fluorescent probe. Wei, Shaoyu Zhang, Liangwei Tan, Jiangkun Liu, Shudi Arabi, Maryam Ostovan, Abbas Zhuang, Xuming Chen, Lingxin Zebrafish Animals Fluorescent Dyes Fluorescent Chemosensor Compounds Humans Sulfhydryl Compounds Oxidative Stress Mercury Glutathione Polymethyl Methacrylate Naphthalimides HeLa Cells Limit of Detection Cysteine Infrared Rays Visualizing the combined toxic effects of micro(nano)plastics and heavy metal ions remains challenging due to the lack of suitable imaging tools, and current co-exposure models are often simplified by simple mixing rather than using pre-formed complexes. In this work, a near-infrared biothiol fluorescent probe was developed based on a naphthalimide scaffold with an α,β-unsaturated acetyl group as a recognition site. The probe exhibits high sensitivity and selectivity toward biothiols, and the detection limit was determined to be 0.47 μM for Cys, 0.37 μM for GSH, and 0.95 μM for Hcy, respectively. This enables the monitoring of biothiol fluctuations in living cells and zebrafish. Using pre-formed PMMA-Hg complexes as co-exposure pollutant models, we investigated nanoplastic-metal ion complex induced oxidative stress in living cells and zebrafish. Imaging results revealed that PMMA-Hg complex co-exposure induces distinct biothiol fluctuation patterns compared to single exposure of PMMA or Hg. The surface charge alterations of complexes and lysosomal function were found to be involved in the process. This study provides visual evidence for elucidating the combined toxicity mechanisms of nanoplastic-heavy metal complex co-exposure.
title Visualizing nanoplastic-metal ion co-exposure stress with an NIR biothiol responsive fluorescent probe.
topic Zebrafish
Animals
Fluorescent Dyes
Fluorescent Chemosensor Compounds
Humans
Sulfhydryl Compounds
Oxidative Stress
Mercury
Glutathione
Polymethyl Methacrylate
Naphthalimides
HeLa Cells
Limit of Detection
Cysteine
Infrared Rays
url https://pubmed.ncbi.nlm.nih.gov/42084039/