Efficient DNA Extraction Coupled with Fluorescence Loop-Mediated Isothermal Amplification (LAMP) for On-Site Early Warning Detection of Vibrio parahaemolyticus.

Fuente: PubMed
Salvato in:
Dettagli Bibliografici
Autori principali: Liu, Fengyi, Geng, Qilin, Sun, Xue, Lin, Jie, Zhu, Xuan, Wang, Danyang, Zhang, Xiao-Hua, Hu, Jingjie, Wang, Shi, Bao, Lisui, Lv, Jia
Natura: Artículo científico
Lingua:en
Pubblicazione: Marine biotechnology (New York, N.Y.) 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1868266041717555200
author Liu, Fengyi
Geng, Qilin
Sun, Xue
Lin, Jie
Zhu, Xuan
Wang, Danyang
Zhang, Xiao-Hua
Hu, Jingjie
Wang, Shi
Bao, Lisui
Lv, Jia
author_facet Liu, Fengyi
Geng, Qilin
Sun, Xue
Lin, Jie
Zhu, Xuan
Wang, Danyang
Zhang, Xiao-Hua
Hu, Jingjie
Wang, Shi
Bao, Lisui
Lv, Jia
Liu, Fengyi
Geng, Qilin
Sun, Xue
Lin, Jie
Zhu, Xuan
Wang, Danyang
Zhang, Xiao-Hua
Hu, Jingjie
Wang, Shi
Bao, Lisui
Lv, Jia
collection PubMed - marine biology
contents Efficient DNA Extraction Coupled with Fluorescence Loop-Mediated Isothermal Amplification (LAMP) for On-Site Early Warning Detection of Vibrio parahaemolyticus. Liu, Fengyi Geng, Qilin Sun, Xue Lin, Jie Zhu, Xuan Wang, Danyang Zhang, Xiao-Hua Hu, Jingjie Wang, Shi Bao, Lisui Lv, Jia Vibrio parahaemolyticus Nucleic Acid Amplification Techniques DNA, Bacterial Animals Sensitivity and Specificity Aquaculture Fluorescence Seawater Molecular Diagnostic Techniques Vibrio Infections Vibrio parahaemolyticus (V. parahaemolyticus), a significant pathogen in aquatic products, necessitates rapid and precise detection to prevent foodborne disease outbreaks. Early detection of bacterial pathogens is crucial for effective prevention and control. In this study, we developed a field-deployable, "sample-in, answer-out" workflow that integrates efficient DNA extraction with visual fluorescence loop-mediated isothermal amplification (LAMP) for the on-site detection of V. parahaemolyticus. This extraction protocol enables efficient one-pot DNA release within 10 min, eliminating the need for additional purification steps. In addition, coupled with an optimized fluorescence LAMP assay targeting V. parahaemolyticus, the entire process-from sample to result-can be completed within approximately 50 min. The optimized assay exhibited high sensitivity, detecting as low as 1 copy/µL of plasmid DNA and 10 CFU per reaction from pure bacterial culture and spiked seawater samples. This extraction-amplification integrated approach demonstrates robust performance and high practicality for on-site early warning and pathogen monitoring in aquaculture safety settings.
format Artículo científico
id pubmed_42240781
institution PubMed
language en
publishDate 2026
publisher Marine biotechnology (New York, N.Y.)
record_format pubmed
spellingShingle Efficient DNA Extraction Coupled with Fluorescence Loop-Mediated Isothermal Amplification (LAMP) for On-Site Early Warning Detection of Vibrio parahaemolyticus.
Liu, Fengyi
Geng, Qilin
Sun, Xue
Lin, Jie
Zhu, Xuan
Wang, Danyang
Zhang, Xiao-Hua
Hu, Jingjie
Wang, Shi
Bao, Lisui
Lv, Jia
Vibrio parahaemolyticus
Nucleic Acid Amplification Techniques
DNA, Bacterial
Animals
Sensitivity and Specificity
Aquaculture
Fluorescence
Seawater
Molecular Diagnostic Techniques
Vibrio Infections
Efficient DNA Extraction Coupled with Fluorescence Loop-Mediated Isothermal Amplification (LAMP) for On-Site Early Warning Detection of Vibrio parahaemolyticus. Liu, Fengyi Geng, Qilin Sun, Xue Lin, Jie Zhu, Xuan Wang, Danyang Zhang, Xiao-Hua Hu, Jingjie Wang, Shi Bao, Lisui Lv, Jia Vibrio parahaemolyticus Nucleic Acid Amplification Techniques DNA, Bacterial Animals Sensitivity and Specificity Aquaculture Fluorescence Seawater Molecular Diagnostic Techniques Vibrio Infections Vibrio parahaemolyticus (V. parahaemolyticus), a significant pathogen in aquatic products, necessitates rapid and precise detection to prevent foodborne disease outbreaks. Early detection of bacterial pathogens is crucial for effective prevention and control. In this study, we developed a field-deployable, "sample-in, answer-out" workflow that integrates efficient DNA extraction with visual fluorescence loop-mediated isothermal amplification (LAMP) for the on-site detection of V. parahaemolyticus. This extraction protocol enables efficient one-pot DNA release within 10 min, eliminating the need for additional purification steps. In addition, coupled with an optimized fluorescence LAMP assay targeting V. parahaemolyticus, the entire process-from sample to result-can be completed within approximately 50 min. The optimized assay exhibited high sensitivity, detecting as low as 1 copy/µL of plasmid DNA and 10 CFU per reaction from pure bacterial culture and spiked seawater samples. This extraction-amplification integrated approach demonstrates robust performance and high practicality for on-site early warning and pathogen monitoring in aquaculture safety settings.
title Efficient DNA Extraction Coupled with Fluorescence Loop-Mediated Isothermal Amplification (LAMP) for On-Site Early Warning Detection of Vibrio parahaemolyticus.
topic Vibrio parahaemolyticus
Nucleic Acid Amplification Techniques
DNA, Bacterial
Animals
Sensitivity and Specificity
Aquaculture
Fluorescence
Seawater
Molecular Diagnostic Techniques
Vibrio Infections
url https://pubmed.ncbi.nlm.nih.gov/42240781/