Clinical effectiveness of light-curing units of the School of Dentistry of the Federal University of Goias

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Laís Santos Gonçalves
Format: Artículo científico
Language:en
Published: Universidade da Região de Joinville 2013
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876479820917899264
author Laís Santos Gonçalves
author_facet Laís Santos Gonçalves
contents Clinical effectiveness of light-curing units of the School of Dentistry of the Federal University of Goias Laís Santos Gonçalves Mércia Bráulio Gonçalves Marília Morais Martins Gersinei Carlos de Freitas Lawrence Gonzaga Lopes Terezinha Jesus Esteves Barata Medicina light sources polymerization resin composites Introduction: The clinical longevity of the procedures is directly associated to the adequate activation (photopolymerization) of adhesive restorative materials. Objective: To evaluate and compare by allocation the conservation status and power density of the light-curing units available at the School of Dentistry of the Federal University of Goias (FO/FUG) for clinical care. Material and methods: The following information and specific techniques of all light sources existing at FO/UFG, available for clinical care in 2011, were collected: dental/ambulatory clinic where they are located, type of source [device of halogen light and light-emitting diode (LED)], brand, parallelism test (halogen light sources), state of conservation of the light transmitter tip, density of the potency/ intensity/irradiance in mW/cm 2 and acquisition date. The data obtained were submitted to one-way ANOVA (Analysis of Variance) and Turkey test for multiple comparisons (P < 0.05). Results: In the second half of 2011, FO/UFG had 20 light sources (04 halogens and 16 LEDs), of which 90% were found in inadequate condition and 55% of those with power density less than 300 mW/cm 2 . There was no statistically significant difference in the power density between halogen and LED sources tested (P = 0.526). Likewise, no statistical difference was observed between the power density of the light sources (LED) placed at the Clinic II and III (P = 0.479). Also there was no statistically significant difference between the light sources (LED Halogen X) at the Clinic I (P = 0.943). Conclusion: The light sources regardless of the clinic in which they were located presented mostly with inadequate clinical effectiveness in terms of their conservation status and power density. 2013 artículo científico 1806-7727 https://www.redalyc.org/articulo.oa?id=153028468006 en http://www.redalyc.org/revista.oa?id=1530 RSBO Revista Sul-Brasileira de Odontologia application/pdf Universidade da Região de Joinville RSBO Revista Sul-Brasileira de Odontologia (Brasil) Num.3 Vol.10
format Artículo científico
id redalyc_153028468006
institution Redalyc
language en
publishDate 2013
publisher Universidade da Região de Joinville
spellingShingle Clinical effectiveness of light-curing units of the School of Dentistry of the Federal University of Goias
Laís Santos Gonçalves
Medicina
light sources
polymerization
resin composites
Clinical effectiveness of light-curing units of the School of Dentistry of the Federal University of Goias Laís Santos Gonçalves Mércia Bráulio Gonçalves Marília Morais Martins Gersinei Carlos de Freitas Lawrence Gonzaga Lopes Terezinha Jesus Esteves Barata Medicina light sources polymerization resin composites Introduction: The clinical longevity of the procedures is directly associated to the adequate activation (photopolymerization) of adhesive restorative materials. Objective: To evaluate and compare by allocation the conservation status and power density of the light-curing units available at the School of Dentistry of the Federal University of Goias (FO/FUG) for clinical care. Material and methods: The following information and specific techniques of all light sources existing at FO/UFG, available for clinical care in 2011, were collected: dental/ambulatory clinic where they are located, type of source [device of halogen light and light-emitting diode (LED)], brand, parallelism test (halogen light sources), state of conservation of the light transmitter tip, density of the potency/ intensity/irradiance in mW/cm 2 and acquisition date. The data obtained were submitted to one-way ANOVA (Analysis of Variance) and Turkey test for multiple comparisons (P < 0.05). Results: In the second half of 2011, FO/UFG had 20 light sources (04 halogens and 16 LEDs), of which 90% were found in inadequate condition and 55% of those with power density less than 300 mW/cm 2 . There was no statistically significant difference in the power density between halogen and LED sources tested (P = 0.526). Likewise, no statistical difference was observed between the power density of the light sources (LED) placed at the Clinic II and III (P = 0.479). Also there was no statistically significant difference between the light sources (LED Halogen X) at the Clinic I (P = 0.943). Conclusion: The light sources regardless of the clinic in which they were located presented mostly with inadequate clinical effectiveness in terms of their conservation status and power density. 2013 artículo científico 1806-7727 https://www.redalyc.org/articulo.oa?id=153028468006 en http://www.redalyc.org/revista.oa?id=1530 RSBO Revista Sul-Brasileira de Odontologia application/pdf Universidade da Região de Joinville RSBO Revista Sul-Brasileira de Odontologia (Brasil) Num.3 Vol.10
title Clinical effectiveness of light-curing units of the School of Dentistry of the Federal University of Goias
topic Medicina
light sources
polymerization
resin composites
url https://www.redalyc.org/articulo.oa?id=153028468006