Fire Risk Assessment in High-Rise Hopitalls in Accordance With NFPA 101

Fuente: Redalyc
Guardado en:
Detalles Bibliográficos
Autor principal: Abdolrasoul Rahmani
Formato: Artículo científico
Lenguaje:en
Publicado: Sociedad Latinoamericana de Hipertensión 2018
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1876461431839260672
author Abdolrasoul Rahmani
author_facet Abdolrasoul Rahmani
contents Fire Risk Assessment in High-Rise Hopitalls in Accordance With NFPA 101 Abdolrasoul Rahmani Mohammad Salem Medicina High NFPA 101 rise hospitals CFSES software Fire risk assessment Protection the high-rise hospitals against fire is very important due to presence of disable patients, hospital’s diverse population, multiple floors and having multiple units on floors. The present study was aimed to assess fire risk in a high-rise hospital. Assessment NFPA healthcare worksheets were extracted from NFPA101 standard completed through field observation. In the next stage, gathered information was analyzed using CFSES software. From all studied zones 100% in the aspects of fire containment and extinguishment were unacceptable. In total, the fire risk level was acceptable in 80% and 100% in the aspects of people movement and general safety, respectively. Our findings indicated that to improve the level of fire risk in high rise hospitals, required measures especially in the area of fire extinguishment and containment including buildings design for automatic sprinkler systems and standardization of fire controls. 2018 artículo científico 1856-4550 https://www.redalyc.org/articulo.oa?id=170263335012 https://www.redalyc.org/journal/1702/170263335012/ https://www.redalyc.org/journal/1702/170263335012/html/ https://www.redalyc.org/journal/1702/170263335012/170263335012.epub https://www.redalyc.org/journal/1702/170263335012/movil en http://www.redalyc.org/revista.oa?id=1702 Revista Latinoamericana de Hipertensión application/pdf Sociedad Latinoamericana de Hipertensión Revista Latinoamericana de Hipertensión (República Bolivariana de Venezuela) Num.3 Vol.13
format Artículo científico
id redalyc_170263335012
institution Redalyc
language en
publishDate 2018
publisher Sociedad Latinoamericana de Hipertensión
spellingShingle Fire Risk Assessment in High-Rise Hopitalls in Accordance With NFPA 101
Abdolrasoul Rahmani
Medicina
High
NFPA 101
rise hospitals
CFSES software
Fire risk assessment
Fire Risk Assessment in High-Rise Hopitalls in Accordance With NFPA 101 Abdolrasoul Rahmani Mohammad Salem Medicina High NFPA 101 rise hospitals CFSES software Fire risk assessment Protection the high-rise hospitals against fire is very important due to presence of disable patients, hospital’s diverse population, multiple floors and having multiple units on floors. The present study was aimed to assess fire risk in a high-rise hospital. Assessment NFPA healthcare worksheets were extracted from NFPA101 standard completed through field observation. In the next stage, gathered information was analyzed using CFSES software. From all studied zones 100% in the aspects of fire containment and extinguishment were unacceptable. In total, the fire risk level was acceptable in 80% and 100% in the aspects of people movement and general safety, respectively. Our findings indicated that to improve the level of fire risk in high rise hospitals, required measures especially in the area of fire extinguishment and containment including buildings design for automatic sprinkler systems and standardization of fire controls. 2018 artículo científico 1856-4550 https://www.redalyc.org/articulo.oa?id=170263335012 https://www.redalyc.org/journal/1702/170263335012/ https://www.redalyc.org/journal/1702/170263335012/html/ https://www.redalyc.org/journal/1702/170263335012/170263335012.epub https://www.redalyc.org/journal/1702/170263335012/movil en http://www.redalyc.org/revista.oa?id=1702 Revista Latinoamericana de Hipertensión application/pdf Sociedad Latinoamericana de Hipertensión Revista Latinoamericana de Hipertensión (República Bolivariana de Venezuela) Num.3 Vol.13
title Fire Risk Assessment in High-Rise Hopitalls in Accordance With NFPA 101
topic Medicina
High
NFPA 101
rise hospitals
CFSES software
Fire risk assessment
url https://www.redalyc.org/articulo.oa?id=170263335012
https://www.redalyc.org/journal/1702/170263335012/
https://www.redalyc.org/journal/1702/170263335012/html/
https://www.redalyc.org/journal/1702/170263335012/170263335012.epub
https://www.redalyc.org/journal/1702/170263335012/movil