Determination of curing heat and curing time of light-cured composite resins by differential scanning calorimetry

Fuente: Redalyc
Enregistré dans:
Détails bibliographiques
Auteur principal: Eduardo Peón Avés
Format: Artículo científico
Langue:en
Publié: Centro Nacional de Investigaciones Científicas 2004
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1876459342200307712
author Eduardo Peón Avés
author_facet Eduardo Peón Avés
contents Determination of curing heat and curing time of light-cured composite resins by differential scanning calorimetry Eduardo Peón Avés Raúl E. López Palacios Luis O. Martínez Alvarez Química Light curing heat time of curing cured composite resins differential sccaning calorimetry The behavior of curing heat of in light-cured restorative composite resins, containing bis-GMA and 3G, was investigated by differential scanning calorimetry (DSC). Visible light-activated polymerization of these monomer systems was studied using camphorquinone (CQ) and dimethylaminoethyl methacrylate (DMAEMA) as reducing agent. In particular, DSC can be easily used to measure the heat of polymerization because of the easy features in the sample preparation. Four samples of a visible lightcured restorative composite resin (two of them unfilled and two filled) were studied at two different light exposition times. The used materials in this study were bis-GMA, 2,2-bis[p-g-methacryloxy-b-hydroxypropoxy)phenyl]- propane; 3G, triethylene glycol dimethacrylate; CQ, camphorquinone and DMAEMA, dimethylaminoethyl+methacrylate. The two filled composites were prepared with silicium dioxide (77 wt %, 30 µm particle size average). A system of thermal analysis Mettler TA-3000, DSC-30 was used to carry out measurements, in an isothermal segment at 37 oC during 5 min under a controlled thermal program. The specimens were polymerized by illuminating them in a DSC apparatus with radiation from a visible light source (Heliolux II) for 0.33 and 0.67 min and the heat output was determined. It seems that the exothermic peak of the DSC curve for lightcured resins depend on the heat of polymerization of each monomer itself contained in the resins. 2004 artículo científico 1015-8553 https://www.redalyc.org/articulo.oa?id=181625914014 en http://www.redalyc.org/revista.oa?id=1816 Revista CENIC. Ciencias Químicas application/pdf Centro Nacional de Investigaciones Científicas Revista CENIC. Ciencias Químicas (Cuba) Num.1 Vol.35
format Artículo científico
id redalyc_181625914014
institution Redalyc
language en
publishDate 2004
publisher Centro Nacional de Investigaciones Científicas
spellingShingle Determination of curing heat and curing time of light-cured composite resins by differential scanning calorimetry
Eduardo Peón Avés
Química
Light
curing heat
time of curing
cured composite resins
differential sccaning calorimetry
Determination of curing heat and curing time of light-cured composite resins by differential scanning calorimetry Eduardo Peón Avés Raúl E. López Palacios Luis O. Martínez Alvarez Química Light curing heat time of curing cured composite resins differential sccaning calorimetry The behavior of curing heat of in light-cured restorative composite resins, containing bis-GMA and 3G, was investigated by differential scanning calorimetry (DSC). Visible light-activated polymerization of these monomer systems was studied using camphorquinone (CQ) and dimethylaminoethyl methacrylate (DMAEMA) as reducing agent. In particular, DSC can be easily used to measure the heat of polymerization because of the easy features in the sample preparation. Four samples of a visible lightcured restorative composite resin (two of them unfilled and two filled) were studied at two different light exposition times. The used materials in this study were bis-GMA, 2,2-bis[p-g-methacryloxy-b-hydroxypropoxy)phenyl]- propane; 3G, triethylene glycol dimethacrylate; CQ, camphorquinone and DMAEMA, dimethylaminoethyl+methacrylate. The two filled composites were prepared with silicium dioxide (77 wt %, 30 µm particle size average). A system of thermal analysis Mettler TA-3000, DSC-30 was used to carry out measurements, in an isothermal segment at 37 oC during 5 min under a controlled thermal program. The specimens were polymerized by illuminating them in a DSC apparatus with radiation from a visible light source (Heliolux II) for 0.33 and 0.67 min and the heat output was determined. It seems that the exothermic peak of the DSC curve for lightcured resins depend on the heat of polymerization of each monomer itself contained in the resins. 2004 artículo científico 1015-8553 https://www.redalyc.org/articulo.oa?id=181625914014 en http://www.redalyc.org/revista.oa?id=1816 Revista CENIC. Ciencias Químicas application/pdf Centro Nacional de Investigaciones Científicas Revista CENIC. Ciencias Químicas (Cuba) Num.1 Vol.35
title Determination of curing heat and curing time of light-cured composite resins by differential scanning calorimetry
topic Química
Light
curing heat
time of curing
cured composite resins
differential sccaning calorimetry
url https://www.redalyc.org/articulo.oa?id=181625914014