Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Leila Rahnama
Format: Artículo científico
Language:en
Published: Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia 2015
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876436608887029760
author Leila Rahnama
author_facet Leila Rahnama
contents Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study Leila Rahnama Asghar Rezasoltani Minoo Khalkhali-Zavieh Behnam Rahnama Farhang Noori-Kochi Salud software neck pain reliability ultrasonography cervical multifidus muscle This study was conducted with the purpose of evaluating the inter-session reliability of new software to measure the diameters of the cervical multifidus muscle (CMM), both at rest and during isometric contractions of the shoulder abductors in subjects with neck pain and in healthy individuals. Method: In the present study, the reliability of measuring the diameters of the CMM with the Sonosynch software was evaluated by using 24 participants, including 12 subjects with chronic neck pain and 12 healthy individuals. The anterior-posterior diameter (APD) and the lateral diameter (LD) of the CMM were measured in a resting state and then repeated during isometric contraction of the shoulder abductors. Measurements were taken on separate occasions 3 to 7 days apart in order to determine inter - session reliability. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest detectable difference (SDD) were used to evaluate the relative and absolute reliability, respectively. Results: The Sonosynch software has shown to be highly reliable in measuring the diameters of the CMM both in healthy subjects and in those with neck pain. The ICCs 95% CI for APD ranged from 0.84 to 0.94 in subjects with neck pain and from 0.86 to 0.94 in healthy subjects. For LD, the ICC 95% CI ranged from 0.64 to 0.95 in subjects with neck pain and from 0.82 to 0.92 in healthy subjects. Conclusions: Ultrasonographic measurement of the diameters of the CMM using Sonosynch has proved to be reliable especially for APD in healthy subjects as well as subjects with neck pain. 2015 artículo científico 1413-3555 https://www.redalyc.org/articulo.oa?id=235041372005 en http://www.redalyc.org/revista.oa?id=2350 Revista Brasileira de Fisioterapia application/pdf Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia Revista Brasileira de Fisioterapia (Brasil) Num.4 Vol.19
format Artículo científico
id redalyc_235041372005
institution Redalyc
language en
publishDate 2015
publisher Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
spellingShingle Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study
Leila Rahnama
Salud
software
neck pain
reliability
ultrasonography
cervical multifidus muscle
Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study Leila Rahnama Asghar Rezasoltani Minoo Khalkhali-Zavieh Behnam Rahnama Farhang Noori-Kochi Salud software neck pain reliability ultrasonography cervical multifidus muscle This study was conducted with the purpose of evaluating the inter-session reliability of new software to measure the diameters of the cervical multifidus muscle (CMM), both at rest and during isometric contractions of the shoulder abductors in subjects with neck pain and in healthy individuals. Method: In the present study, the reliability of measuring the diameters of the CMM with the Sonosynch software was evaluated by using 24 participants, including 12 subjects with chronic neck pain and 12 healthy individuals. The anterior-posterior diameter (APD) and the lateral diameter (LD) of the CMM were measured in a resting state and then repeated during isometric contraction of the shoulder abductors. Measurements were taken on separate occasions 3 to 7 days apart in order to determine inter - session reliability. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and smallest detectable difference (SDD) were used to evaluate the relative and absolute reliability, respectively. Results: The Sonosynch software has shown to be highly reliable in measuring the diameters of the CMM both in healthy subjects and in those with neck pain. The ICCs 95% CI for APD ranged from 0.84 to 0.94 in subjects with neck pain and from 0.86 to 0.94 in healthy subjects. For LD, the ICC 95% CI ranged from 0.64 to 0.95 in subjects with neck pain and from 0.82 to 0.92 in healthy subjects. Conclusions: Ultrasonographic measurement of the diameters of the CMM using Sonosynch has proved to be reliable especially for APD in healthy subjects as well as subjects with neck pain. 2015 artículo científico 1413-3555 https://www.redalyc.org/articulo.oa?id=235041372005 en http://www.redalyc.org/revista.oa?id=2350 Revista Brasileira de Fisioterapia application/pdf Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia Revista Brasileira de Fisioterapia (Brasil) Num.4 Vol.19
title Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study
topic Salud
software
neck pain
reliability
ultrasonography
cervical multifidus muscle
url https://www.redalyc.org/articulo.oa?id=235041372005