Should we stop using the determination of central venous pressure as a way to estimate cardiac preload?

Fuente: Redalyc
Salvato in:
Dettagli Bibliografici
Autore principale: Johann Smith Cerón Arias
Natura: Artículo científico
Lingua:en
Pubblicazione: Universidad del Valle 2012
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1876448165145608192
author Johann Smith Cerón Arias
author_facet Johann Smith Cerón Arias
contents Should we stop using the determination of central venous pressure as a way to estimate cardiac preload? Johann Smith Cerón Arias Manuel Felipe Muñoz Ñañez Medicina end global end blood volume stroke volume diastolic area The determination of the values of central venous pressure has long been used as a guideline for volumetric therapy in there suscitation of the critical patient, but the performance of such parameter is currently beingquestioned as an effective measurement of cardiac preload. This has aroused great interest in the search for more accurate parameters to determine cardiac preload and a patient¿s blood volume. Goals and Methodology: Based on literature currently available, we aim to discuss the performance of central venous pressure as an effective parameter to determine cardiac preload. Results and Conclusion: Estimating variables such as end-diastolic ventricular area and globalend-diastolic volume have a better performance than central venous pressure in determining cardiac preload. Despite thebest performance of these devices, central venous pressure is still considered in our setting as the most practical and most commonly available way to assess the patient's preload.Only dynamic variables such as pulse pressure change are superior in determining an individual's blood volume. 2012 artículo científico 0120-8322 https://www.redalyc.org/articulo.oa?id=28323195012 https://www.redalyc.org/journal/283/28323195012/ https://www.redalyc.org/journal/283/28323195012/html/ https://www.redalyc.org/journal/283/28323195012/28323195012.epub https://www.redalyc.org/journal/283/28323195012/movil en http://www.redalyc.org/revista.oa?id=283 Colombia Médica application/pdf Universidad del Valle Colombia Médica (Colombia) Num.2 Vol.43
format Artículo científico
id redalyc_28323195012
institution Redalyc
language en
publishDate 2012
publisher Universidad del Valle
spellingShingle Should we stop using the determination of central venous pressure as a way to estimate cardiac preload?
Johann Smith Cerón Arias
Medicina
end
global end
blood volume
stroke volume
diastolic area
Should we stop using the determination of central venous pressure as a way to estimate cardiac preload? Johann Smith Cerón Arias Manuel Felipe Muñoz Ñañez Medicina end global end blood volume stroke volume diastolic area The determination of the values of central venous pressure has long been used as a guideline for volumetric therapy in there suscitation of the critical patient, but the performance of such parameter is currently beingquestioned as an effective measurement of cardiac preload. This has aroused great interest in the search for more accurate parameters to determine cardiac preload and a patient¿s blood volume. Goals and Methodology: Based on literature currently available, we aim to discuss the performance of central venous pressure as an effective parameter to determine cardiac preload. Results and Conclusion: Estimating variables such as end-diastolic ventricular area and globalend-diastolic volume have a better performance than central venous pressure in determining cardiac preload. Despite thebest performance of these devices, central venous pressure is still considered in our setting as the most practical and most commonly available way to assess the patient's preload.Only dynamic variables such as pulse pressure change are superior in determining an individual's blood volume. 2012 artículo científico 0120-8322 https://www.redalyc.org/articulo.oa?id=28323195012 https://www.redalyc.org/journal/283/28323195012/ https://www.redalyc.org/journal/283/28323195012/html/ https://www.redalyc.org/journal/283/28323195012/28323195012.epub https://www.redalyc.org/journal/283/28323195012/movil en http://www.redalyc.org/revista.oa?id=283 Colombia Médica application/pdf Universidad del Valle Colombia Médica (Colombia) Num.2 Vol.43
title Should we stop using the determination of central venous pressure as a way to estimate cardiac preload?
topic Medicina
end
global end
blood volume
stroke volume
diastolic area
url https://www.redalyc.org/articulo.oa?id=28323195012
https://www.redalyc.org/journal/283/28323195012/
https://www.redalyc.org/journal/283/28323195012/html/
https://www.redalyc.org/journal/283/28323195012/28323195012.epub
https://www.redalyc.org/journal/283/28323195012/movil