Numerical simulation of blood fluid in hemodialysis catheters and its thrombogenic potential
Fuente:
Redalyc
Salvato in:
| Autore principale: | |
|---|---|
| Natura: | Artículo científico |
| Lingua: | en |
| Pubblicazione: |
Universidade Estadual de Maringá
2019
|
| Soggetti: | |
| Accesso online: | |
| Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
| _version_ | 1876440229805555712 |
|---|---|
| author | Thabata Coaglio Lucas |
| author_facet | Thabata Coaglio Lucas |
| contents | Numerical simulation of blood fluid in hemodialysis catheters and its thrombogenic potential Thabata Coaglio Lucas Jonathas Haniel Rudolf Huebner Medicina fibrin Hydrodynamics vascular access devices diagnostic techniques and procedures The present study aimed to numerically simulate blood flow within central venous catheters of hemodialysis and its thrombogenic potential. Numerical simulation research performed through the dynamic computational program of fluids. A three-dimensional geometry of right and left internal jugular veins were built, taken from the Visible Human Project®. Catheters with obstructed and unobstructed lateral holes were constructed. For the simulation, we considered the duration of the cardiac cycle of 0.8 s with pulsatile cycle of 75 beats per minute. Shear stress, velocity and pressure increased when the catheter was within the vein and when they were obstructed. At the venous orifice of the catheter that was unobstructed, the velocity increased from 0.99 ± 0.02 m s-1 to 1.79 ± 0.009 m s-1 and the pressure from 1487 ± 0.8 Pa to 3215 ± 0.7 Pa. Blood re-circulation areas have created areas of stagnation of blood flow, making it more susceptible to the development of venous thrombi. This study may contribute to the expansion of multiprofessional partnerships between health professionals and Bioengineering fields in order to study health problems that can be verified through advanced technologies. Such technologies, such as simulation programs, detail possible adverse events based on scientific evidences which often occur silently in patients. 2019 artículo científico 1679-9291 https://www.redalyc.org/articulo.oa?id=307261031027 https://www.redalyc.org/journal/3072/307261031027/ https://www.redalyc.org/journal/3072/307261031027/html/ https://www.redalyc.org/journal/3072/307261031027/307261031027.epub https://www.redalyc.org/journal/3072/307261031027/movil https://doi.org/10.4025/actascihealthsci.v41i1.45613 en http://www.redalyc.org/revista.oa?id=3072 Acta Scientiarum. Health Sciences application/pdf Universidade Estadual de Maringá Acta Scientiarum. Health Sciences (Brasil) Vol.41 |
| format | Artículo científico |
| id | redalyc_307261031027 |
| institution | Redalyc |
| language | en |
| publishDate | 2019 |
| publisher | Universidade Estadual de Maringá |
| spellingShingle | Numerical simulation of blood fluid in hemodialysis catheters and its thrombogenic potential Thabata Coaglio Lucas Medicina fibrin Hydrodynamics vascular access devices diagnostic techniques and procedures Numerical simulation of blood fluid in hemodialysis catheters and its thrombogenic potential Thabata Coaglio Lucas Jonathas Haniel Rudolf Huebner Medicina fibrin Hydrodynamics vascular access devices diagnostic techniques and procedures The present study aimed to numerically simulate blood flow within central venous catheters of hemodialysis and its thrombogenic potential. Numerical simulation research performed through the dynamic computational program of fluids. A three-dimensional geometry of right and left internal jugular veins were built, taken from the Visible Human Project®. Catheters with obstructed and unobstructed lateral holes were constructed. For the simulation, we considered the duration of the cardiac cycle of 0.8 s with pulsatile cycle of 75 beats per minute. Shear stress, velocity and pressure increased when the catheter was within the vein and when they were obstructed. At the venous orifice of the catheter that was unobstructed, the velocity increased from 0.99 ± 0.02 m s-1 to 1.79 ± 0.009 m s-1 and the pressure from 1487 ± 0.8 Pa to 3215 ± 0.7 Pa. Blood re-circulation areas have created areas of stagnation of blood flow, making it more susceptible to the development of venous thrombi. This study may contribute to the expansion of multiprofessional partnerships between health professionals and Bioengineering fields in order to study health problems that can be verified through advanced technologies. Such technologies, such as simulation programs, detail possible adverse events based on scientific evidences which often occur silently in patients. 2019 artículo científico 1679-9291 https://www.redalyc.org/articulo.oa?id=307261031027 https://www.redalyc.org/journal/3072/307261031027/ https://www.redalyc.org/journal/3072/307261031027/html/ https://www.redalyc.org/journal/3072/307261031027/307261031027.epub https://www.redalyc.org/journal/3072/307261031027/movil https://doi.org/10.4025/actascihealthsci.v41i1.45613 en http://www.redalyc.org/revista.oa?id=3072 Acta Scientiarum. Health Sciences application/pdf Universidade Estadual de Maringá Acta Scientiarum. Health Sciences (Brasil) Vol.41 |
| title | Numerical simulation of blood fluid in hemodialysis catheters and its thrombogenic potential |
| topic | Medicina fibrin Hydrodynamics vascular access devices diagnostic techniques and procedures |
| url | https://www.redalyc.org/articulo.oa?id=307261031027 https://www.redalyc.org/journal/3072/307261031027/ https://www.redalyc.org/journal/3072/307261031027/html/ https://www.redalyc.org/journal/3072/307261031027/307261031027.epub https://www.redalyc.org/journal/3072/307261031027/movil https://doi.org/10.4025/actascihealthsci.v41i1.45613 |