Middle Latency Responses (MLR) in Brazilian children and adolescents: systematic review

Fuente: Redalyc
Guardado en:
Detalles Bibliográficos
Autor principal: Aline Rejane Rosa de Castro
Formato: Artículo científico
Lenguaje:en
Publicado: Academia Brasileira de Audiologia 2015
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1876476786440667136
author Aline Rejane Rosa de Castro
author_facet Aline Rejane Rosa de Castro
contents Middle Latency Responses (MLR) in Brazilian children and adolescents: systematic review Aline Rejane Rosa de Castro Simone Rosa Barreto Patrícia Cotta Mancini Luciana Macedo de Resende Salud Child Review Hearing Auditory Adolescent Purpose: Systematically review the scientific literature on Middle Latency Response (MLR) in Brazilian children and adolescents. Research strategy: We searched articles published since 2009 in Portuguese, English or Spanish at MEDLINE, SciELO, BIREME and LILACS electronic basis. Selected articles involved the use of MLR in children and / or Brazilian adolescents. After screening process, articles were analyzed according to “Strengthening the Reporting of Observational Studies in Epidemiology” (STROBE) initiative. Selection criteria: Repeated articles (due to database repetition) and case reports were excluded. Results: From 1315 identified articles, eight were selected for the review. It was predominantly observed: cross-sectional studies (75%); click stimulation (100%), with rate up to 11/s (100%) and 70 dBHL intensity (88%); filtering high-pass 10 Hz (50%) and low-pass 200 Hz (75%); electrode array with actives placed at C3/ C4, references at A1/A2 and neutral at Fpz (88%); Na-Pa amplitude as main measure of comparison and normality; and the use of ANOVA test (63%) for statistical analyses. The average latency of Pa wave and Na-Pa amplitude in normal-hearing children and adolescents of the studies was 32 milliseconds and 1.57 microvolts respectively. Conclusion: There is no consensus on MLR collection parameters in Brazilian children and adolescents. Still, the Pa latency average and Na-Pa amplitude found in Brazilian normal-hearing children and adolescents evaluated on the eight articles of this review agreed with normative parameters established internationally. 2015 artículo científico 2317-6431 https://www.redalyc.org/articulo.oa?id=391544064014 en http://www.redalyc.org/revista.oa?id=3915 Audiology - Communication Research application/pdf Academia Brasileira de Audiologia Audiology - Communication Research (Brasil) Num.4 Vol.20
format Artículo científico
id redalyc_391544064014
institution Redalyc
language en
publishDate 2015
publisher Academia Brasileira de Audiologia
spellingShingle Middle Latency Responses (MLR) in Brazilian children and adolescents: systematic review
Aline Rejane Rosa de Castro
Salud
Child
Review
Hearing
Auditory
Adolescent
Middle Latency Responses (MLR) in Brazilian children and adolescents: systematic review Aline Rejane Rosa de Castro Simone Rosa Barreto Patrícia Cotta Mancini Luciana Macedo de Resende Salud Child Review Hearing Auditory Adolescent Purpose: Systematically review the scientific literature on Middle Latency Response (MLR) in Brazilian children and adolescents. Research strategy: We searched articles published since 2009 in Portuguese, English or Spanish at MEDLINE, SciELO, BIREME and LILACS electronic basis. Selected articles involved the use of MLR in children and / or Brazilian adolescents. After screening process, articles were analyzed according to “Strengthening the Reporting of Observational Studies in Epidemiology” (STROBE) initiative. Selection criteria: Repeated articles (due to database repetition) and case reports were excluded. Results: From 1315 identified articles, eight were selected for the review. It was predominantly observed: cross-sectional studies (75%); click stimulation (100%), with rate up to 11/s (100%) and 70 dBHL intensity (88%); filtering high-pass 10 Hz (50%) and low-pass 200 Hz (75%); electrode array with actives placed at C3/ C4, references at A1/A2 and neutral at Fpz (88%); Na-Pa amplitude as main measure of comparison and normality; and the use of ANOVA test (63%) for statistical analyses. The average latency of Pa wave and Na-Pa amplitude in normal-hearing children and adolescents of the studies was 32 milliseconds and 1.57 microvolts respectively. Conclusion: There is no consensus on MLR collection parameters in Brazilian children and adolescents. Still, the Pa latency average and Na-Pa amplitude found in Brazilian normal-hearing children and adolescents evaluated on the eight articles of this review agreed with normative parameters established internationally. 2015 artículo científico 2317-6431 https://www.redalyc.org/articulo.oa?id=391544064014 en http://www.redalyc.org/revista.oa?id=3915 Audiology - Communication Research application/pdf Academia Brasileira de Audiologia Audiology - Communication Research (Brasil) Num.4 Vol.20
title Middle Latency Responses (MLR) in Brazilian children and adolescents: systematic review
topic Salud
Child
Review
Hearing
Auditory
Adolescent
url https://www.redalyc.org/articulo.oa?id=391544064014