Late outcome of right ventricular outflow tractrepair using bicuspid pulmonary prosthesis intetralogy of Fallot surgery repair: case report
Fuente:
Redalyc
Salvato in:
| Autore principale: | |
|---|---|
| Natura: | Artículo científico |
| Lingua: | en |
| Pubblicazione: |
Sociedade Brasileira de Cirurgia Cardiovascular
2009
|
| Soggetti: | |
| Accesso online: | |
| Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
| _version_ | 1876441959225098240 |
|---|---|
| author | Miguel Angel MALUF |
| author_facet | Miguel Angel MALUF |
| contents | Late outcome of right ventricular outflow tractrepair using bicuspid pulmonary prosthesis intetralogy of Fallot surgery repair: case report Miguel Angel MALUF Medicina surgery congenital Heart defects Treatment outcome Tetralogy of Fallot We present a case of a 19 year-old female patient, with tetralogy of Fallot and hypoplastic pulmonary ring. Diagnosis was performed by echocardiography and cardiac catheterization. The surgical repair was performed at the age of 2 years old. A right ventricular outflow tract remodeling was performed using a porcine pulmonary bicuspid prosthesis. The patient presented a uneventful follow-up during 17 years. Postoperative assessment has shown: mild pulmonary insufficiency and mild pulmonary ventricle gradient, satisfactory right ventricular performance and prosthesis not presenting calcification. This is an option to correct the tetralogy of Fallot adopted by our Institution in the last two decades. 2009 artículo científico 0102-7638 https://www.redalyc.org/articulo.oa?id=398941873021 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.4 Vol.24 |
| format | Artículo científico |
| id | redalyc_398941873021 |
| institution | Redalyc |
| language | en |
| publishDate | 2009 |
| publisher | Sociedade Brasileira de Cirurgia Cardiovascular |
| spellingShingle | Late outcome of right ventricular outflow tractrepair using bicuspid pulmonary prosthesis intetralogy of Fallot surgery repair: case report Miguel Angel MALUF Medicina surgery congenital Heart defects Treatment outcome Tetralogy of Fallot Late outcome of right ventricular outflow tractrepair using bicuspid pulmonary prosthesis intetralogy of Fallot surgery repair: case report Miguel Angel MALUF Medicina surgery congenital Heart defects Treatment outcome Tetralogy of Fallot We present a case of a 19 year-old female patient, with tetralogy of Fallot and hypoplastic pulmonary ring. Diagnosis was performed by echocardiography and cardiac catheterization. The surgical repair was performed at the age of 2 years old. A right ventricular outflow tract remodeling was performed using a porcine pulmonary bicuspid prosthesis. The patient presented a uneventful follow-up during 17 years. Postoperative assessment has shown: mild pulmonary insufficiency and mild pulmonary ventricle gradient, satisfactory right ventricular performance and prosthesis not presenting calcification. This is an option to correct the tetralogy of Fallot adopted by our Institution in the last two decades. 2009 artículo científico 0102-7638 https://www.redalyc.org/articulo.oa?id=398941873021 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.4 Vol.24 |
| title | Late outcome of right ventricular outflow tractrepair using bicuspid pulmonary prosthesis intetralogy of Fallot surgery repair: case report |
| topic | Medicina surgery congenital Heart defects Treatment outcome Tetralogy of Fallot |
| url | https://www.redalyc.org/articulo.oa?id=398941873021 |