Results of Castro Bernardes intraluminal ring in surgery for ascending aortic aneurysms and dissections

Fuente: Redalyc
Enregistré dans:
Détails bibliographiques
Auteur principal: Fernando Rotatori Novaes
Format: Artículo científico
Langue:en
Publié: Sociedade Brasileira de Cirurgia Cardiovascular 2013
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1876430752834387968
author Fernando Rotatori Novaes
author_facet Fernando Rotatori Novaes
contents Results of Castro Bernardes intraluminal ring in surgery for ascending aortic aneurysms and dissections Fernando Rotatori Novaes Tulio Pinho Navarro Rodrigo de Castro Bernardes Fernando Antonio Roquete Reis Pinto Luiz Cláudio Moreira Lima Ernesto Lentz da Silveira Monteiro Carla Patrícia Perpétua Medeiros Medicina Aneurysm dissecting Aortic aneurysm Blood vessel prosthesis Objective: To demonstrate surgical results using Castro Bernardes intraluminal ring in ascending aorta surgery, instead of conventional suture. Methods: 95 patients underwent ascending aorta surgery from December 2008 to April 2011 at Madre Tereza Hospital (Belo Horizonte, MG, Brazil), using Castro Bernardes intraluminal ring instead of conventional suture of the aorta. Results: Ninety five patients underwent ascending aorta surgery with Castro-Bernardes intraluminal ring. Thirty patients presented acute dissection and 65 aneurism. Overall postoperative mortality was 15.78% (15/95). Nine patients in 15 (60%) died due to acute type A dissection. For acute type A dissection, mortality was 30% and for aneurism mortality was 9.23%. The intraluminal ring was inserted in distal position in 89 patients and in proximal and distal position in 6 patients. Mortality was related to Bentall & De Bono or Cabrol associated techniques. Average extracorporeal circulation time was 57.4 minutes and average aortic cross-clamping time was 37 minutes. Conclusion: The use of Castro Bernardes intraluminal ring in ascending aortic surgery avoiding conventional suture reduces extracorporeal circulation time and aortic cross-clamping time, improving surgical results. This approach simplifies ascending aortic surgery whether the disease is type A dissection or aneurysm, and may be considered a good alternative technique. 2013 artículo científico 0102-7638 https://www.redalyc.org/articulo.oa?id=398941889005 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.2 Vol.28
format Artículo científico
id redalyc_398941889005
institution Redalyc
language en
publishDate 2013
publisher Sociedade Brasileira de Cirurgia Cardiovascular
spellingShingle Results of Castro Bernardes intraluminal ring in surgery for ascending aortic aneurysms and dissections
Fernando Rotatori Novaes
Medicina
Aneurysm
dissecting
Aortic aneurysm
Blood vessel prosthesis
Results of Castro Bernardes intraluminal ring in surgery for ascending aortic aneurysms and dissections Fernando Rotatori Novaes Tulio Pinho Navarro Rodrigo de Castro Bernardes Fernando Antonio Roquete Reis Pinto Luiz Cláudio Moreira Lima Ernesto Lentz da Silveira Monteiro Carla Patrícia Perpétua Medeiros Medicina Aneurysm dissecting Aortic aneurysm Blood vessel prosthesis Objective: To demonstrate surgical results using Castro Bernardes intraluminal ring in ascending aorta surgery, instead of conventional suture. Methods: 95 patients underwent ascending aorta surgery from December 2008 to April 2011 at Madre Tereza Hospital (Belo Horizonte, MG, Brazil), using Castro Bernardes intraluminal ring instead of conventional suture of the aorta. Results: Ninety five patients underwent ascending aorta surgery with Castro-Bernardes intraluminal ring. Thirty patients presented acute dissection and 65 aneurism. Overall postoperative mortality was 15.78% (15/95). Nine patients in 15 (60%) died due to acute type A dissection. For acute type A dissection, mortality was 30% and for aneurism mortality was 9.23%. The intraluminal ring was inserted in distal position in 89 patients and in proximal and distal position in 6 patients. Mortality was related to Bentall & De Bono or Cabrol associated techniques. Average extracorporeal circulation time was 57.4 minutes and average aortic cross-clamping time was 37 minutes. Conclusion: The use of Castro Bernardes intraluminal ring in ascending aortic surgery avoiding conventional suture reduces extracorporeal circulation time and aortic cross-clamping time, improving surgical results. This approach simplifies ascending aortic surgery whether the disease is type A dissection or aneurysm, and may be considered a good alternative technique. 2013 artículo científico 0102-7638 https://www.redalyc.org/articulo.oa?id=398941889005 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.2 Vol.28
title Results of Castro Bernardes intraluminal ring in surgery for ascending aortic aneurysms and dissections
topic Medicina
Aneurysm
dissecting
Aortic aneurysm
Blood vessel prosthesis
url https://www.redalyc.org/articulo.oa?id=398941889005