Saved in:
Bibliographic Details
Main Author: Giovani José Dal Poggetto Molinari
Format: Artículo científico
Language:pt
Published: Sociedade Brasileira de Cirurgia Cardiovascular 2014
Subjects:
Online Access:https://www.redalyc.org/articulo.oa?id=398941892014
Tags: Add Tag
No Tags, Be the first to tag this record!
Table of Contents:
  • Proposta de correção virtual geométrica da projeção ostial da artéria renal no estudo operatório de aneurismas infrarrenais: resultados iniciais de um estudo piloto Giovani José Dal Poggetto Molinari Andreia Marques de Oliveira Dalbem Fabio Hüsemann Menezes Ana Terezinha Guillaumon Medicina User Abdominal Renal Artery Pilot Projects Aortic Aneurysm Introduction: Endovascular aneurysm repair requires the precise deployment of the graft. In order to achieve accurate positioning, the anatomical and morphological characteristics of the aorta and its branches is mandatory. Software that perform three dimensional reformatting of multislice tomographic images, allow for the study of the whole aorto-iliac axis and the perpendicular visualization of the origin of the renal arteries. The correct length of the proximal neck can be evaluated and adequate graft fixation and sealing may be foreseen. A technique is presented, using an software, for the orthogonal correction of the position of the renal arteries in relation to the proximal neck, which may guide the radioscopic orientation intraoperatively. Methods: Within a multiplanar tomographic image reconstruction, virtual triangulation allows for the three dimensional orthogonal correction of the renal arteries' ostia position. The predetermined best angulations for visualization are annotated and used for the positioning of the surgical C-arm. Results/Discussion: Some authors discuss that the anatomic position of the renal vessels seen on the tomographic scan can change during the surgical procedure. It is known that the renal arterys' angular positioning does not alter, even after insertion of stiff guidewires, introducers, and the endograft itself. Therefore, it is possible, using concepts of spacial geometry and orthogonal correction, to predict the ideal bidimensional intraoperative positioning of the radioscopy device in order to reproduce the optimized renal artery ostial projection, ensuring the best accuracy during endograft deployment. Conclusion: As closer to the tomographic reproduction was the radioscopic correction, more careful is the visualization of the ostium of the renal artery, better is the exploitation of the lap for fixing and sealing and the endoprosthesis deployment is more accurate. 2014 artículo científico 0102-7638 https://www.redalyc.org/articulo.oa?id=398941892014 pt http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.1 Vol.29