Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation - prospective study of 704 cases

Fuente: Redalyc
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: José Carlos Pachón Mateos
Format: Artículo científico
Sprache:en
Veröffentlicht: Sociedade Brasileira de Cirurgia Cardiovascular 2015
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1876442418049449984
author José Carlos Pachón Mateos
author_facet José Carlos Pachón Mateos
contents Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation - prospective study of 704 cases José Carlos Pachón Mateos Enrique I Pachón Mateos Tomas G Santillana Peña Tasso Julio Lobo Juán Carlos Pachón Mateos Remy Nelson A Vargas Carlos Thiene C Pachón Juán Carlos Zerpa Acosta Medicina Esophagus Catheter Ablation Esophageal Fistula Atrial Fibrillation Introduction: Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality . Objective: This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibril - lation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Methods: Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8±14 [17-84] years old), with mean EF of 0.66±0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmo - nary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiog - raphy transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. Results: The mean esophageal displacement was 4 to 9.1cm (5.9±0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40 o C/irri - gated catheter or 50W/60 o C/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11±0.13 o C versus 1.1±0.4 o C respectively, P <0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echo - cardiography transducer insertion were observed. Conclusion: Mechanical esophageal displacement by transe - sophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most cases, the esophageal displacement was sufficient to allow safe ra - diofrequency application without esophagus overlapping, being a convenient alternative in reducing the risk of atrioesophageal fistula. 2015 artículo científico 0102-7638 https://www.redalyc.org/articulo.oa?id=398941897003 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.2 Vol.30
format Artículo científico
id redalyc_398941897003
institution Redalyc
language en
publishDate 2015
publisher Sociedade Brasileira de Cirurgia Cardiovascular
spellingShingle Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation - prospective study of 704 cases
José Carlos Pachón Mateos
Medicina
Esophagus
Catheter Ablation
Esophageal Fistula
Atrial Fibrillation
Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation - prospective study of 704 cases José Carlos Pachón Mateos Enrique I Pachón Mateos Tomas G Santillana Peña Tasso Julio Lobo Juán Carlos Pachón Mateos Remy Nelson A Vargas Carlos Thiene C Pachón Juán Carlos Zerpa Acosta Medicina Esophagus Catheter Ablation Esophageal Fistula Atrial Fibrillation Introduction: Although rare, the atrioesophageal fistula is one of the most feared complications in radiofrequency catheter ablation of atrial fibrillation due to the high risk of mortality . Objective: This is a prospective controlled study, performed during regular radiofrequency catheter ablation of atrial fibril - lation, to test whether esophageal displacement by handling the transesophageal echocardiography transducer could be used for esophageal protection. Methods: Seven hundred and four patients (158 F/546M [22.4%/77.6%]; 52.8±14 [17-84] years old), with mean EF of 0.66±0.8 and drug-refractory atrial fibrillation were submitted to hybrid radiofrequency catheter ablation (conventional pulmo - nary vein isolation plus AF-Nests and background tachycardia ablation) with displacement of the esophagus as far as possible from the radiofrequency target by transesophageal echocardiog - raphy transducer handling. The esophageal luminal temperature was monitored without and with displacement in 25 patients. Results: The mean esophageal displacement was 4 to 9.1cm (5.9±0.8 cm). In 680 of the 704 patients (96.6%), it was enough to allow complete and safe radiofrequency delivery (30W/40 o C/irri - gated catheter or 50W/60 o C/8 mm catheter) without esophagus overlapping. The mean esophageal luminal temperature changes with versus without esophageal displacement were 0.11±0.13 o C versus 1.1±0.4 o C respectively, P <0.01. The radiofrequency had to be halted in 68% of the patients without esophageal displacement because of esophageal luminal temperature increase. There was no incidence of atrioesophageal fistula suspected or confirmed. Only two superficial bleeding caused by transesophageal echo - cardiography transducer insertion were observed. Conclusion: Mechanical esophageal displacement by transe - sophageal echocardiography transducer during radiofrequency catheter ablation was able to prevent a rise in esophageal luminal temperature, helping to avoid esophageal thermal lesion. In most cases, the esophageal displacement was sufficient to allow safe ra - diofrequency application without esophagus overlapping, being a convenient alternative in reducing the risk of atrioesophageal fistula. 2015 artículo científico 0102-7638 https://www.redalyc.org/articulo.oa?id=398941897003 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.2 Vol.30
title Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation - prospective study of 704 cases
topic Medicina
Esophagus
Catheter Ablation
Esophageal Fistula
Atrial Fibrillation
url https://www.redalyc.org/articulo.oa?id=398941897003