| author | Fan Yang |
| author_facet | Fan Yang |
| contents | Safety and Feasibility Study of a Novel Stent-Graft for Thoracic Endovascular Aortic Repair: a Canine Model Experiment Fan Yang Jiehua Qiu Zeliang Fu Yuchen Qiu Junrong Luo Qingyang Xiao Huabin Cao Medicina Dogs Stent graft Models Animal Objective: To evaluate the safety and feasibility of a novel stent-graft for thoracic endovascular aortic repair (TEVAR) in a canine model, 9 adult hybrid dogs were used for the experiment. Methods: All animals were implanted with a novel thoracic aortic stent-graft via femoral artery. Blood sample was collected at pre-operation and 1, 2, 4, 8 and 12 weeks after implantation for hematological examination. Moreover, tissues from randomly selected 4 dogs were subjected to histopathological analysis with the optical microscope after stent-grafts were implanted for 3, 6, 9, and 12 months respectively. The experimental period lasted for more than 2 years. Results: A total of 9 stent-grafts were successfully implanted in the canine thoracic aortas and no migration or deformation occurred. Related indicators of blood routine, inflammatory factors, and immunology changes were not significantly (P>0.05), except the white blood cell (WBC) counts in the first week. Moreover, abnormal morphology was not found in all thoracic aortas via histopathological examination. Additionally, all stent-grafts were patent and did not migrate, and there was no thrombus in the lumens of stent-grafts. Conclusion: The novel thoracic aortic stent-graft made in China was safe and feasible for thoracic endovascular aortic repair in a canine model. 2017 artículo científico 0102-7638 https://www.redalyc.org/articulo.oa?id=398953453012 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.5 Vol.32 |
| format | Artículo científico |
| id | redalyc_398953453012 |
| language | en |
| publishDate | 2017 |
| publisher | Sociedade Brasileira de Cirurgia Cardiovascular |
| spellingShingle | Safety and Feasibility Study of a Novel Stent-Graft for Thoracic Endovascular Aortic Repair: a Canine Model Experiment Fan Yang Medicina Dogs Stent graft Models Animal Safety and Feasibility Study of a Novel Stent-Graft for Thoracic Endovascular Aortic Repair: a Canine Model Experiment Fan Yang Jiehua Qiu Zeliang Fu Yuchen Qiu Junrong Luo Qingyang Xiao Huabin Cao Medicina Dogs Stent graft Models Animal Objective: To evaluate the safety and feasibility of a novel stent-graft for thoracic endovascular aortic repair (TEVAR) in a canine model, 9 adult hybrid dogs were used for the experiment. Methods: All animals were implanted with a novel thoracic aortic stent-graft via femoral artery. Blood sample was collected at pre-operation and 1, 2, 4, 8 and 12 weeks after implantation for hematological examination. Moreover, tissues from randomly selected 4 dogs were subjected to histopathological analysis with the optical microscope after stent-grafts were implanted for 3, 6, 9, and 12 months respectively. The experimental period lasted for more than 2 years. Results: A total of 9 stent-grafts were successfully implanted in the canine thoracic aortas and no migration or deformation occurred. Related indicators of blood routine, inflammatory factors, and immunology changes were not significantly (P>0.05), except the white blood cell (WBC) counts in the first week. Moreover, abnormal morphology was not found in all thoracic aortas via histopathological examination. Additionally, all stent-grafts were patent and did not migrate, and there was no thrombus in the lumens of stent-grafts. Conclusion: The novel thoracic aortic stent-graft made in China was safe and feasible for thoracic endovascular aortic repair in a canine model. 2017 artículo científico 0102-7638 https://www.redalyc.org/articulo.oa?id=398953453012 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.5 Vol.32 |
| title | Safety and Feasibility Study of a Novel Stent-Graft for Thoracic Endovascular Aortic Repair: a Canine Model Experiment |
| topic | Medicina Dogs Stent graft Models Animal |
| url | https://www.redalyc.org/articulo.oa?id=398953453012 |