Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral Valve Replacement: Meta-Analysis of 10,239 Patients

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: Michel Pompeu Barros Oliveira Sá
Format: Artículo científico
Language:en
Published: Sociedade Brasileira de Cirurgia Cardiovascular 2019
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876443319819567104
author Michel Pompeu Barros Oliveira Sá
author_facet Michel Pompeu Barros Oliveira Sá
contents Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral Valve Replacement: Meta-Analysis of 10,239 Patients Michel Pompeu Barros Oliveira Sá Luiz Rafael Pereira Cavalcanti Sérgio da Costa Rayol Roberto Gouvea Silva Diniz Alexandre Motta Menezes Marie-Annick Clavel Philippe Pibarot Ricardo Carvalho Lima Medicina Meta Surgery Analysis Prosthesis Mitral Valve Objective: This study sought to evaluate the impact of prosthesis-patient mismatch on the risk of perioperative and longterm mortality after mitral valve replacement. Methods: Databases were researched for studies published until December 2018. Main outcomes of interest were perioperative and 10-year mortality and echocardiographic parameters. Results: The research yielded 2,985 studies for inclusion. Of these, 16 articles were analyzed, and their data extracted. The total number of patients included was 10,239, who underwent mitral valve replacement. The incidence of prosthesis-patient mismatch after mitral valve replacement was 53.7% (5,499 with prosthesispatient mismatch and 4,740 without prosthesis-patient mismatch). Perioperative (OR 1.519; 95%CI 1.194–1.931, P<0.001) and 10-year (OR 1.515; 95%CI 1.280–1.795, P<0.001) mortality was increased in patients with prosthesis-patient mismatch. Patients with prosthesis-patient mismatch after mitral valve replacement had higher systolic pulmonary artery pressure and transprosthethic gradient and lower indexed effective orifice area and left ventricle ejection fraction. Conclusion: Prosthesis-patient mismatch increases perioperative and long-term mortality. Prosthesis-patient mismatch is also associated with pulmonary hypertension and depressed left ventricle systolic function. The findings of this study support the implementation of surgical strategies to prevent prosthesispatient mismatch in order to decrease mortality rates. 2019 artículo científico 0102-7638 https://www.redalyc.org/articulo.oa?id=398959097014 https://www.redalyc.org/journal/3989/398959097014/ https://www.redalyc.org/journal/3989/398959097014/html/ https://www.redalyc.org/journal/3989/398959097014/398959097014.epub https://www.redalyc.org/journal/3989/398959097014/movil 10.21470/1678-9741-2019-0069 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.2 Vol.34
format Artículo científico
id redalyc_398959097014
institution Redalyc
language en
publishDate 2019
publisher Sociedade Brasileira de Cirurgia Cardiovascular
spellingShingle Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral Valve Replacement: Meta-Analysis of 10,239 Patients
Michel Pompeu Barros Oliveira Sá
Medicina
Meta
Surgery
Analysis
Prosthesis
Mitral Valve
Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral Valve Replacement: Meta-Analysis of 10,239 Patients Michel Pompeu Barros Oliveira Sá Luiz Rafael Pereira Cavalcanti Sérgio da Costa Rayol Roberto Gouvea Silva Diniz Alexandre Motta Menezes Marie-Annick Clavel Philippe Pibarot Ricardo Carvalho Lima Medicina Meta Surgery Analysis Prosthesis Mitral Valve Objective: This study sought to evaluate the impact of prosthesis-patient mismatch on the risk of perioperative and longterm mortality after mitral valve replacement. Methods: Databases were researched for studies published until December 2018. Main outcomes of interest were perioperative and 10-year mortality and echocardiographic parameters. Results: The research yielded 2,985 studies for inclusion. Of these, 16 articles were analyzed, and their data extracted. The total number of patients included was 10,239, who underwent mitral valve replacement. The incidence of prosthesis-patient mismatch after mitral valve replacement was 53.7% (5,499 with prosthesispatient mismatch and 4,740 without prosthesis-patient mismatch). Perioperative (OR 1.519; 95%CI 1.194–1.931, P<0.001) and 10-year (OR 1.515; 95%CI 1.280–1.795, P<0.001) mortality was increased in patients with prosthesis-patient mismatch. Patients with prosthesis-patient mismatch after mitral valve replacement had higher systolic pulmonary artery pressure and transprosthethic gradient and lower indexed effective orifice area and left ventricle ejection fraction. Conclusion: Prosthesis-patient mismatch increases perioperative and long-term mortality. Prosthesis-patient mismatch is also associated with pulmonary hypertension and depressed left ventricle systolic function. The findings of this study support the implementation of surgical strategies to prevent prosthesispatient mismatch in order to decrease mortality rates. 2019 artículo científico 0102-7638 https://www.redalyc.org/articulo.oa?id=398959097014 https://www.redalyc.org/journal/3989/398959097014/ https://www.redalyc.org/journal/3989/398959097014/html/ https://www.redalyc.org/journal/3989/398959097014/398959097014.epub https://www.redalyc.org/journal/3989/398959097014/movil 10.21470/1678-9741-2019-0069 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.2 Vol.34
title Prosthesis-Patient Mismatch Negatively Affects Outcomes after Mitral Valve Replacement: Meta-Analysis of 10,239 Patients
topic Medicina
Meta
Surgery
Analysis
Prosthesis
Mitral Valve
url https://www.redalyc.org/articulo.oa?id=398959097014
https://www.redalyc.org/journal/3989/398959097014/
https://www.redalyc.org/journal/3989/398959097014/html/
https://www.redalyc.org/journal/3989/398959097014/398959097014.epub
https://www.redalyc.org/journal/3989/398959097014/movil