Never Give Up: Deep Hypothermic Circulatory Arrest for Transcatheter Mitral Edge-To-Edge Repair Failure in Porcelain Aorta - A Case Report
Fuente:
Redalyc
Guardado en:
| Autor principal: | |
|---|---|
| Formato: | Artículo científico |
| Lenguaje: | en |
| Publicado: |
Sociedade Brasileira de Cirurgia Cardiovascular
2025
|
| Materias: | |
| Acceso en línea: | |
| Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
| _version_ | 1876423208549220352 |
|---|---|
| author | Antonio Davide Conserva |
| author_facet | Antonio Davide Conserva |
| contents | Never Give Up: Deep Hypothermic Circulatory Arrest for Transcatheter Mitral Edge-To-Edge Repair Failure in Porcelain Aorta - A Case Report Antonio Davide Conserva Giovanni Troise Pompilio Faggiano Elena Conti Antonio Messina Emmanuel Villa Medicina Aorta Mitral valve bioprosthesis thoracic surgery circulatory arrest We report the case of a surgical treatment after transcatheter edge-to-edge mitral valve repair failure in a 79-year-old patient who had undergone cardiac surgery 30 years earlier. The transcatheter procedure of mitral valve got complicated by single leaflet device attachment leading to recurrent severe regurgitation. Despite the extremely high surgical risk and a porcelain aorta, we deemed the patient operable thanks to his performant physical and cognitive status. He underwent mitral valve replacement with a bioprosthesis in deep hypothermic circulatory arrest and retrograde cerebral perfusion. The postoperative course was regular, and he is in good functional class at one-year follow-up. 2025 otro 0102-7638 https://www.redalyc.org/articulo.oa?id=398982952001 https://www.redalyc.org/journal/3989/398982952001/ https://www.redalyc.org/journal/3989/398982952001/html/ https://www.redalyc.org/journal/3989/398982952001/398982952001.epub https://www.redalyc.org/journal/3989/398982952001/movil 10.21470/1678-9741-2024-0129 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.6 Vol.40 |
| format | Artículo científico |
| id | redalyc_398982952001 |
| institution | Redalyc |
| language | en |
| publishDate | 2025 |
| publisher | Sociedade Brasileira de Cirurgia Cardiovascular |
| spellingShingle | Never Give Up: Deep Hypothermic Circulatory Arrest for Transcatheter Mitral Edge-To-Edge Repair Failure in Porcelain Aorta - A Case Report Antonio Davide Conserva Medicina Aorta Mitral valve bioprosthesis thoracic surgery circulatory arrest Never Give Up: Deep Hypothermic Circulatory Arrest for Transcatheter Mitral Edge-To-Edge Repair Failure in Porcelain Aorta - A Case Report Antonio Davide Conserva Giovanni Troise Pompilio Faggiano Elena Conti Antonio Messina Emmanuel Villa Medicina Aorta Mitral valve bioprosthesis thoracic surgery circulatory arrest We report the case of a surgical treatment after transcatheter edge-to-edge mitral valve repair failure in a 79-year-old patient who had undergone cardiac surgery 30 years earlier. The transcatheter procedure of mitral valve got complicated by single leaflet device attachment leading to recurrent severe regurgitation. Despite the extremely high surgical risk and a porcelain aorta, we deemed the patient operable thanks to his performant physical and cognitive status. He underwent mitral valve replacement with a bioprosthesis in deep hypothermic circulatory arrest and retrograde cerebral perfusion. The postoperative course was regular, and he is in good functional class at one-year follow-up. 2025 otro 0102-7638 https://www.redalyc.org/articulo.oa?id=398982952001 https://www.redalyc.org/journal/3989/398982952001/ https://www.redalyc.org/journal/3989/398982952001/html/ https://www.redalyc.org/journal/3989/398982952001/398982952001.epub https://www.redalyc.org/journal/3989/398982952001/movil 10.21470/1678-9741-2024-0129 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.6 Vol.40 |
| title | Never Give Up: Deep Hypothermic Circulatory Arrest for Transcatheter Mitral Edge-To-Edge Repair Failure in Porcelain Aorta - A Case Report |
| topic | Medicina Aorta Mitral valve bioprosthesis thoracic surgery circulatory arrest |
| url | https://www.redalyc.org/articulo.oa?id=398982952001 https://www.redalyc.org/journal/3989/398982952001/ https://www.redalyc.org/journal/3989/398982952001/html/ https://www.redalyc.org/journal/3989/398982952001/398982952001.epub https://www.redalyc.org/journal/3989/398982952001/movil |