Never Give Up: Deep Hypothermic Circulatory Arrest for Transcatheter Mitral Edge-To-Edge Repair Failure in Porcelain Aorta - A Case Report

Fuente: Redalyc
Guardado en:
Detalles Bibliográficos
Autor principal: Antonio Davide Conserva
Formato: Artículo científico
Lenguaje:en
Publicado: Sociedade Brasileira de Cirurgia Cardiovascular 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1876423208549220352
author Antonio Davide Conserva
author_facet Antonio Davide Conserva
contents Never Give Up: Deep Hypothermic Circulatory Arrest for Transcatheter Mitral Edge-To-Edge Repair Failure in Porcelain Aorta - A Case Report Antonio Davide Conserva Giovanni Troise Pompilio Faggiano Elena Conti Antonio Messina Emmanuel Villa Medicina Aorta Mitral valve bioprosthesis thoracic surgery circulatory arrest We report the case of a surgical treatment after transcatheter edge-to-edge mitral valve repair failure in a 79-year-old patient who had undergone cardiac surgery 30 years earlier. The transcatheter procedure of mitral valve got complicated by single leaflet device attachment leading to recurrent severe regurgitation. Despite the extremely high surgical risk and a porcelain aorta, we deemed the patient operable thanks to his performant physical and cognitive status. He underwent mitral valve replacement with a bioprosthesis in deep hypothermic circulatory arrest and retrograde cerebral perfusion. The postoperative course was regular, and he is in good functional class at one-year follow-up. 2025 otro 0102-7638 https://www.redalyc.org/articulo.oa?id=398982952001 https://www.redalyc.org/journal/3989/398982952001/ https://www.redalyc.org/journal/3989/398982952001/html/ https://www.redalyc.org/journal/3989/398982952001/398982952001.epub https://www.redalyc.org/journal/3989/398982952001/movil 10.21470/1678-9741-2024-0129 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.6 Vol.40
format Artículo científico
id redalyc_398982952001
institution Redalyc
language en
publishDate 2025
publisher Sociedade Brasileira de Cirurgia Cardiovascular
spellingShingle Never Give Up: Deep Hypothermic Circulatory Arrest for Transcatheter Mitral Edge-To-Edge Repair Failure in Porcelain Aorta - A Case Report
Antonio Davide Conserva
Medicina
Aorta
Mitral valve
bioprosthesis
thoracic surgery
circulatory arrest
Never Give Up: Deep Hypothermic Circulatory Arrest for Transcatheter Mitral Edge-To-Edge Repair Failure in Porcelain Aorta - A Case Report Antonio Davide Conserva Giovanni Troise Pompilio Faggiano Elena Conti Antonio Messina Emmanuel Villa Medicina Aorta Mitral valve bioprosthesis thoracic surgery circulatory arrest We report the case of a surgical treatment after transcatheter edge-to-edge mitral valve repair failure in a 79-year-old patient who had undergone cardiac surgery 30 years earlier. The transcatheter procedure of mitral valve got complicated by single leaflet device attachment leading to recurrent severe regurgitation. Despite the extremely high surgical risk and a porcelain aorta, we deemed the patient operable thanks to his performant physical and cognitive status. He underwent mitral valve replacement with a bioprosthesis in deep hypothermic circulatory arrest and retrograde cerebral perfusion. The postoperative course was regular, and he is in good functional class at one-year follow-up. 2025 otro 0102-7638 https://www.redalyc.org/articulo.oa?id=398982952001 https://www.redalyc.org/journal/3989/398982952001/ https://www.redalyc.org/journal/3989/398982952001/html/ https://www.redalyc.org/journal/3989/398982952001/398982952001.epub https://www.redalyc.org/journal/3989/398982952001/movil 10.21470/1678-9741-2024-0129 en http://www.redalyc.org/revista.oa?id=3989 Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery application/pdf Sociedade Brasileira de Cirurgia Cardiovascular Revista Brasileira de Cirurgia Cardiovascular/Brazilian Journal of Cardiovascular Surgery (Brasil) Num.6 Vol.40
title Never Give Up: Deep Hypothermic Circulatory Arrest for Transcatheter Mitral Edge-To-Edge Repair Failure in Porcelain Aorta - A Case Report
topic Medicina
Aorta
Mitral valve
bioprosthesis
thoracic surgery
circulatory arrest
url https://www.redalyc.org/articulo.oa?id=398982952001
https://www.redalyc.org/journal/3989/398982952001/
https://www.redalyc.org/journal/3989/398982952001/html/
https://www.redalyc.org/journal/3989/398982952001/398982952001.epub
https://www.redalyc.org/journal/3989/398982952001/movil