Use of experimental design in the optimisation of a solid phase preconcentration system for Cobalt determination by GFAAS
Fuente:
Redalyc
Saved in:
| Main Author: | |
|---|---|
| Format: | Artículo científico |
| Language: | en |
| Published: |
Universidade Estadual Paulista Júlio de Mesquita Filho
2005
|
| Subjects: | |
| Online Access: | |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1876468295626915840 |
|---|---|
| author | G. D. Matos |
| author_facet | G. D. Matos |
| contents | Use of experimental design in the optimisation of a solid phase preconcentration system for Cobalt determination by GFAAS G. D. Matos C. R. T. Tarley S. L. C. Ferreira M. A. Z. Arruda Química cobalt polyurethane foam Experimental Designs preconcentration system In this work is proposed a solid phase preconcentration system of Co2+ ions and its posteriordetermination by GFAAS in which fractional factorial design and response surface methodology (RSM)were used for optimization of the variables associated with preconcentration system performance. Themethod is based on cobalt extraction as a complex Co2+-PAN (1:2) in a mini-column of polyurethane foam(PUF) impregnated with 1-(2-pyridylazo)-naphthol (PAN) followed by elution with HCl solution and itsdetermination by GFAAS. The chemical and flow variables studied were pH, buffer concentration, eluentconcentration and preconcentration and elution flow rates. Results obtained from fractional factorialdesign 25-1 showed that only the variables pH, buffer concentration and interaction (pH X bufferconcentration) based on analysis of variance (ANOVA) were statistically significant at 95% confidencelevel. Under optimised conditions, the method provided an enrichment factor of 11.6 fold with limit ofdetection and quantification of 38 and 130 ng L-1, respectively, and linear range varying from 0.13 to 10µg L-1. The precision (n = 9) assessed by relative standard deviation (RSD) was respectively 5.18 and2.87% for 0.3 and 3.0 µg L-1 cobalt concentrations. 2005 artículo científico 0100-4670 https://www.redalyc.org/articulo.oa?id=42930109 en http://www.redalyc.org/revista.oa?id=429 Eclética Química application/pdf Universidade Estadual Paulista Júlio de Mesquita Filho Eclética Química (Brasil) Num.1 Vol.30 |
| format | Artículo científico |
| id | redalyc_42930109 |
| institution | Redalyc |
| language | en |
| publishDate | 2005 |
| publisher | Universidade Estadual Paulista Júlio de Mesquita Filho |
| spellingShingle | Use of experimental design in the optimisation of a solid phase preconcentration system for Cobalt determination by GFAAS G. D. Matos Química cobalt polyurethane foam Experimental Designs preconcentration system Use of experimental design in the optimisation of a solid phase preconcentration system for Cobalt determination by GFAAS G. D. Matos C. R. T. Tarley S. L. C. Ferreira M. A. Z. Arruda Química cobalt polyurethane foam Experimental Designs preconcentration system In this work is proposed a solid phase preconcentration system of Co2+ ions and its posteriordetermination by GFAAS in which fractional factorial design and response surface methodology (RSM)were used for optimization of the variables associated with preconcentration system performance. Themethod is based on cobalt extraction as a complex Co2+-PAN (1:2) in a mini-column of polyurethane foam(PUF) impregnated with 1-(2-pyridylazo)-naphthol (PAN) followed by elution with HCl solution and itsdetermination by GFAAS. The chemical and flow variables studied were pH, buffer concentration, eluentconcentration and preconcentration and elution flow rates. Results obtained from fractional factorialdesign 25-1 showed that only the variables pH, buffer concentration and interaction (pH X bufferconcentration) based on analysis of variance (ANOVA) were statistically significant at 95% confidencelevel. Under optimised conditions, the method provided an enrichment factor of 11.6 fold with limit ofdetection and quantification of 38 and 130 ng L-1, respectively, and linear range varying from 0.13 to 10µg L-1. The precision (n = 9) assessed by relative standard deviation (RSD) was respectively 5.18 and2.87% for 0.3 and 3.0 µg L-1 cobalt concentrations. 2005 artículo científico 0100-4670 https://www.redalyc.org/articulo.oa?id=42930109 en http://www.redalyc.org/revista.oa?id=429 Eclética Química application/pdf Universidade Estadual Paulista Júlio de Mesquita Filho Eclética Química (Brasil) Num.1 Vol.30 |
| title | Use of experimental design in the optimisation of a solid phase preconcentration system for Cobalt determination by GFAAS |
| topic | Química cobalt polyurethane foam Experimental Designs preconcentration system |
| url | https://www.redalyc.org/articulo.oa?id=42930109 |