Use of experimental design in the optimisation of a solid phase preconcentration system for Cobalt determination by GFAAS

Fuente: Redalyc
Saved in:
Bibliographic Details
Main Author: G. D. Matos
Format: Artículo científico
Language:en
Published: Universidade Estadual Paulista Júlio de Mesquita Filho 2005
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1876468295626915840
author G. D. Matos
author_facet G. D. Matos
contents Use of experimental design in the optimisation of a solid phase preconcentration system for Cobalt determination by GFAAS G. D. Matos C. R. T. Tarley S. L. C. Ferreira M. A. Z. Arruda Química cobalt polyurethane foam Experimental Designs preconcentration system In this work is proposed a solid phase preconcentration system of Co2+ ions and its posteriordetermination by GFAAS in which fractional factorial design and response surface methodology (RSM)were used for optimization of the variables associated with preconcentration system performance. Themethod is based on cobalt extraction as a complex Co2+-PAN (1:2) in a mini-column of polyurethane foam(PUF) impregnated with 1-(2-pyridylazo)-naphthol (PAN) followed by elution with HCl solution and itsdetermination by GFAAS. The chemical and flow variables studied were pH, buffer concentration, eluentconcentration and preconcentration and elution flow rates. Results obtained from fractional factorialdesign 25-1 showed that only the variables pH, buffer concentration and interaction (pH X bufferconcentration) based on analysis of variance (ANOVA) were statistically significant at 95% confidencelevel. Under optimised conditions, the method provided an enrichment factor of 11.6 fold with limit ofdetection and quantification of 38 and 130 ng L-1, respectively, and linear range varying from 0.13 to 10µg L-1. The precision (n = 9) assessed by relative standard deviation (RSD) was respectively 5.18 and2.87% for 0.3 and 3.0 µg L-1 cobalt concentrations. 2005 artículo científico 0100-4670 https://www.redalyc.org/articulo.oa?id=42930109 en http://www.redalyc.org/revista.oa?id=429 Eclética Química application/pdf Universidade Estadual Paulista Júlio de Mesquita Filho Eclética Química (Brasil) Num.1 Vol.30
format Artículo científico
id redalyc_42930109
institution Redalyc
language en
publishDate 2005
publisher Universidade Estadual Paulista Júlio de Mesquita Filho
spellingShingle Use of experimental design in the optimisation of a solid phase preconcentration system for Cobalt determination by GFAAS
G. D. Matos
Química
cobalt
polyurethane foam
Experimental Designs
preconcentration system
Use of experimental design in the optimisation of a solid phase preconcentration system for Cobalt determination by GFAAS G. D. Matos C. R. T. Tarley S. L. C. Ferreira M. A. Z. Arruda Química cobalt polyurethane foam Experimental Designs preconcentration system In this work is proposed a solid phase preconcentration system of Co2+ ions and its posteriordetermination by GFAAS in which fractional factorial design and response surface methodology (RSM)were used for optimization of the variables associated with preconcentration system performance. Themethod is based on cobalt extraction as a complex Co2+-PAN (1:2) in a mini-column of polyurethane foam(PUF) impregnated with 1-(2-pyridylazo)-naphthol (PAN) followed by elution with HCl solution and itsdetermination by GFAAS. The chemical and flow variables studied were pH, buffer concentration, eluentconcentration and preconcentration and elution flow rates. Results obtained from fractional factorialdesign 25-1 showed that only the variables pH, buffer concentration and interaction (pH X bufferconcentration) based on analysis of variance (ANOVA) were statistically significant at 95% confidencelevel. Under optimised conditions, the method provided an enrichment factor of 11.6 fold with limit ofdetection and quantification of 38 and 130 ng L-1, respectively, and linear range varying from 0.13 to 10µg L-1. The precision (n = 9) assessed by relative standard deviation (RSD) was respectively 5.18 and2.87% for 0.3 and 3.0 µg L-1 cobalt concentrations. 2005 artículo científico 0100-4670 https://www.redalyc.org/articulo.oa?id=42930109 en http://www.redalyc.org/revista.oa?id=429 Eclética Química application/pdf Universidade Estadual Paulista Júlio de Mesquita Filho Eclética Química (Brasil) Num.1 Vol.30
title Use of experimental design in the optimisation of a solid phase preconcentration system for Cobalt determination by GFAAS
topic Química
cobalt
polyurethane foam
Experimental Designs
preconcentration system
url https://www.redalyc.org/articulo.oa?id=42930109