Salvato in:
Dettagli Bibliografici
Autore principale: O. M. Guimarães
Natura: Artículo científico
Lingua:en
Pubblicazione: Universidade Estadual Paulista Júlio de Mesquita Filho 2006
Soggetti:
Accesso online:https://www.redalyc.org/articulo.oa?id=42931403
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866557608482045952
author O. M. Guimarães
author_facet O. M. Guimarães
contents Determination of carbon monoxide using a coated quartz crystal sensor O. M. Guimarães M. E. D. Zaniquell J. R. M. Castro V. R. Balbo J. F. Andrade Química quartz crystal carbon monoxide piezoelectric sensor phthalocyanine nickel(II) Carbon monoxide was detected and determined by a piezoelectric quartz crystal sensorcoated with nickel(II)-phthalocyanine 50 % (v/v) solution in glycerine. Studies on the effect oftemperature, flow rate, and some possible interferents were carried out. Calibration curves, sensorstability (lifetime) and the precision of measurements were also verified. The resulting selectivity isprobably due to the coordinative binding between the electronically unsatured metal complexes and theanalyte. The analytical curve is linear in the concentration range 0.10 to 1.0 % (v/v). 2006 artículo científico 0100-4670 https://www.redalyc.org/articulo.oa?id=42931403 en http://www.redalyc.org/revista.oa?id=429 Eclética Química application/pdf Universidade Estadual Paulista Júlio de Mesquita Filho Eclética Química (Brasil) Num.4 Vol.31
format Artículo científico
id redalyc_42931403
language en
publishDate 2006
publisher Universidade Estadual Paulista Júlio de Mesquita Filho
spellingShingle Determination of carbon monoxide using a coated quartz crystal sensor
O. M. Guimarães
Química
quartz crystal
carbon monoxide
piezoelectric sensor
phthalocyanine nickel(II)
Determination of carbon monoxide using a coated quartz crystal sensor O. M. Guimarães M. E. D. Zaniquell J. R. M. Castro V. R. Balbo J. F. Andrade Química quartz crystal carbon monoxide piezoelectric sensor phthalocyanine nickel(II) Carbon monoxide was detected and determined by a piezoelectric quartz crystal sensorcoated with nickel(II)-phthalocyanine 50 % (v/v) solution in glycerine. Studies on the effect oftemperature, flow rate, and some possible interferents were carried out. Calibration curves, sensorstability (lifetime) and the precision of measurements were also verified. The resulting selectivity isprobably due to the coordinative binding between the electronically unsatured metal complexes and theanalyte. The analytical curve is linear in the concentration range 0.10 to 1.0 % (v/v). 2006 artículo científico 0100-4670 https://www.redalyc.org/articulo.oa?id=42931403 en http://www.redalyc.org/revista.oa?id=429 Eclética Química application/pdf Universidade Estadual Paulista Júlio de Mesquita Filho Eclética Química (Brasil) Num.4 Vol.31
title Determination of carbon monoxide using a coated quartz crystal sensor
topic Química
quartz crystal
carbon monoxide
piezoelectric sensor
phthalocyanine nickel(II)
url https://www.redalyc.org/articulo.oa?id=42931403